Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 10, 2019 FBO #6438
SOLICITATION NOTICE

66 -- Nitrogen Gas Generator

Notice Date
7/8/2019
 
Notice Type
Combine Synopsis/Solicitation
 
Contracting Office
Bartlett Hall, Bldg 753, West point, NY 10996
 
ZIP Code
22030
 
Solicitation Number
DRUMUSMACLSTMH0027
 
Response Due
7/12/2019
 
Archive Date
1/8/2020
 
Point of Contact
Name: Client Services, Title: Client Services, Phone: 1.877.933.3243, Fax: 703.422.7822
 
E-Mail Address
Clientservices@fedbid.com;
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. The solicitation number is DRUMUSMACLSTMH0027 and is issued as a Request for Quote (RFQ), unless otherwise indicated herein. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2019-03. The associated North American Industrial Classification System (NAICS) code for this procurement is 334516 with a small business size standard of 500.00 employees. This requirement is a [ Small Business ] set-aside and only qualified offerors may submit bids. The solicitation pricing on www.UnisonMarketplace.com will start on the date this solicitation is posted and will end on 2019-07-12 13:00:00.0 Eastern Time or as otherwise displayed at www.UnisonMarketplace.com. FOB Destination shall be West Point, NY 10996 The MICC End User requires the following items, Brand Name or Equal, to the following: LI 001: The nitrogen generator must allow for multi-stage purification and next-generation integrated compressors with electronic compressor optimization technology. The nitrogen generator must be delivered with factory certification that the nitrogen gas generator can provide gas on demand up to a purity of 99.5%. Key Features Must be capable of variable flow up to 35 L/min (LPM) Must be capable of variable pressure up to 116 psi (8 bar) Must include multi-stage purification that produces analytical grade nitrogen gas up to 99.5% purity Must have touch screen interface for ease of operation, including performance monitoring, start-up status check and on-board service scheduling and system diagnostics. Must use intelligent managing of compressor run time when generator is in operation and complete power down of compressor when no gas is demanded to reduce energy consumption while maximizing generator performance in terms of gas delivery and longevity/reliability of component parts. Must include two state active moisture safeguard and reheat technology and lock and drain system to protect applications against any risk of moisture contamination while offering very dry nitrogen gas. Must include heat distribution management to optimize air inlet flow and internal air circulation focusing on air compressors. Must provide improved compressor and membrane reliability/performance through better internal heat management. Must have a non-methane hydrocarbon (NMHC) filtration system to reduce spectral interference from ambient hydrocarbon contamination through NMHC capture. Must be compatible with Thermo, Agilent, Shimadzu, Advion, Waters, Sciex, Perkin Elmer, and Bruker instruments. Required technical specifications for the nitrogen generator are as follows: Max Flow Rate: up to 35 L/min Max Pressure: 116 psi (8 bar) Gas Outlets: 1 x BSPP Purity: 95-99.5% (factory certified purity with respect to O2 content with minimum 95% purity at maximum flow output) Max Relative Humidity (RH): 80% RH at 31 C Max Altitude: 2000 m Particles: particles less than 0.01 μm Phthalates: phthalate & BHT Free Suspended Liquids: none Non-Methane Hydrocarbon Content: non-methane hydrocarbon content is less than 1 ppm NMHC. Operating Temperature: 15 C (59 F) to 35 C (95 F) Electrical Requirements: 120VAC, 60Hz, 12A Power Consumption: no more than 960 VA (120V) Heat Output: not more than 4118 BTU Noise Level: not more than 56 dB Generator Dimensions (H x W x D): no larger than 25.6 in x 22.5 in x 28 in Generator Weight: Not more than 92 kg / 202 lbs Bids must include shipping to 10996 Bids must include installation and minimum 12 month warranty with onsite service/ repair NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (08-JUL-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/notices/f8e07b84ccee5558a46eddbe063aeae6)
 
Place of Performance
Address: West Point, NY 10996
Zip Code: 10996
Country: US
 
Record
SN05362643-F 20190710/190708230027 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.