SOLICITATION NOTICE
J -- Pneumatic Controls Service
- Notice Date
- 6/20/2019
- Notice Type
- Synopsis
- NAICS
- 811310
— Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Contracting Office
- Department of Veterans Affairs;VA Connecticut;950 Campbell Avenue;West Haven CT 06516
- ZIP Code
- 06516
- Solicitation Number
- 36C24119Q0268
- Response Due
- 6/27/2019
- Archive Date
- 8/26/2019
- Point of Contact
- Contracting Officer
- Small Business Set-Aside
- N/A
- Description
- Pursuant to Federal Acquisition Regulation (FAR) 8.405-6(a)(1)(i)(B), The Connecticut Health Care System for the Department of Veterans Affairs intends to issue a sole source contract award to Quincy Compressor LLC 14500 Lochridge blvd Ste A Covington, GA 30014-4941. The contract will include Preventive Maintenance & Repair Service for Medical Air Compressors and Vacuum Pumps for Connecticut HCS Facilities and Maintenance 950 Campbell Avenue West Haven, CT 06516. The applicable NAICS code will be 811310 with an applicable small business size standard of $7.5 Million. The performance period is for a 1-year period with an option of four years and will provide all equipment, labor, materials; to include tools, parts, transportation, supervision, permits and disposal necessary to service all medical air, medical vacuum, and compressed air for pneumatic controls with all associated dryers, sensors and monitors at the West Haven VA Medical Center, 950 Campbell Ave., West Haven, CT 06516. Contractor to be responsible for obtaining mfg. Spec s as needed with copies for engineering dept. The Connecticut HCS has warranties currently being serviced by Quincy Compressor and use of another vendor would void these warranties. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. It is a market research tool being used to determine the availability of other qualified sources that can meet the requirements identified above and inherent with the referenced product. The Government is not obligated to and will not pay for any information received from potential sources as a result of this notice of intent. All responses received within 15 days of the posting of this notice will be considered by the Government. A determination by the Government to require services for The Connecticut HCS, acquisition based on this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purposes of determining whether to allow alternate service providers. Submit any responses within 4 days of the posting of the notice of intent via email to: cory.dionne@va.gov. THIS NOTICE OF INTENT IS NOT A REQUEST FOR PROPOSALS OR QUOTATIONS. No solicitation package will be issued. A determination by the Government not to compete this proposed action based upon responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether conducting a competitive procurement is in the best interest of the Government. All responses received by 13:00 EST on 26 June 2019 will be considered by the Government. This notice is not a request for competitive proposals/quotes. All information submitted should support the offeror's capability to provide the items required and shall be furnished at no cost or obligation to the Government. Responses must be in writing and must provide clear and concise documentation indicating an offeror's capability to provide these services. Verbal responses are not acceptable and will not be considered. Responses and questions shall be submitted via email to: cory.dionne@va.gov. The Government will issue a Limited Sources Justification (LSJ) to support the need for a sole source award. The LSJ will post to the GPE at http://www.fedbizopps.gov, within fourteen (14) days after award of the task order. Statement of Work Preventive Maintenance & Repair Service for Medical Air Compressors and Vacuum Pumps for VA Connecticut Healthcare System West Haven, CT Contractor shall provide all equipment, labor, materials; to include tools, parts, transportation, supervision, permits and disposal necessary to service all medical air, medical vacuum, and compressed air for pneumatic controls with all associated dryers, sensors and monitors at the West Haven VA Medical Center, 950 Campbell Ave., West Haven, CT 06516. Contractor to be responsible for obtaining mfg. Spec s as needed with copies for engineering dept. Preventive Maintenance The contractor shall provide a monthly walk-through to inspect all equipment listed on bid spec on the equipment listed below: QTY MFG Description / Medical Air / Medical Vacuum Bldg/Location 1 Beacon Medical Vacuum / Model # OV8A-ITBS-TC001 SER# 65503 1-SG182 1 Quincy Medical Vacuum / Model # QSVB10 SER# UNO64010 1- 5th Floor 1 Quincy Medical Vacuum / Model# QSVB10 SER# UNO640009 1-5th Floor 1 Busch Medical Vacuum / Model# MM1104AB SER# 050044109 2-7-100 1 Airtech Dental Vacuum / Model# 1-DV-7620-5-TANV #959 2-G-139 1 Chemtron Medical Vacuum / Model# LPHR 50518 BN11 7020 2-G-139 SER# 348618 SER# 3448619 1 Airtech Research Vacuum / Model# 2BL2061-1AH50-4AS200 4-Basement 1 Power-X Medical Air / Model# SPL3471698 Cat Number M3218T 1-5th Floor 1 Power-x Medical Air / Model# SPL3485304 Cat Number MS218T 1-SG-182 1 Power-X Medical Air / Model# SET150740 1-SG-177 1 Power-X Dental Air / Model# SET150740E 2-G-139 1 Power-X Medical Air / Model# SPL2923735 2-G-139 1 Speed Air Pneumatic Air / Model# 4YN50A SER# 2008-00040 2-2-113 (Wood Shop) 1 Quincy Pneumatic Air / Model# PLT-5 SER# 200301120-01956 2-2-113 1 Quincy Pneumatic Air / Model# PLT-5 SER# 6144416 2-2-113 1 Quincy Pneumatic Air / Model# 390 SER# 339931 2-G-139 1 Quincy Pneumatic Air / Model# 390L103 SER# 400451RL 2-G-139 1 Quincy Pneumatic Air / Model# 310 SER# 20041018-0013 2-G-139 1 Quincy Pneumatic Air / Model# QT5QCB SER# 20060112 4-Basement 1 Quincy Pneumatic Air / Model# QT5QCB SER# 200602240057 Bldg 34 1 Quincy Pneumatic Air / Model# 310 SER# 20041018-0011 1-SG-101 1 Hitachi Pneumatic Air / Model# 5-5OU-8.5CH SER# OC858837 1-SG-170 1 Quincy Pneumatic Air / Model# QSB15ANA11SQ SER# 97726H 1-SG-182 1 Kobelco Pneumatic Air / Model# KNWA00-A/L SER# 01A0106 1-SG-182 1 Quincy Pneumatic Air / Model# QSB15ANA11SQ SER# 97725H 1-10th Floor 1 Quincy Pneumatic Air / Model# 390101 SER# 339932 1-10th Floor 1 Johnson Control Pneumatic Air / Model# AD030 SER# 050692L-209094 1-5th Floor 1 Ingersol Pneumatic Air / Model# BS15 SER# 100309 Boiler Plant QTY MFG Description / Pneumatic Control Air/Fire Suppression Bldg/Location 1 Quincy Pneumatic Air / Model# 390 QRV-ROCO Boiler Plant 1 Quincy Pneumatic Air / Model# QT5QCB SER# 20060224-0055 Bldg 21 1 Jenny Fire Suppression / Model FIS-BS SER# G072JJ4020 Boiler Plant 1 Jenny Fire Suppression / Model# K SER# F122211025 3-Basement 1 Magnetech Fire Suppression / Model 8-164550-23 7-Basement Reciprocating compressors will be serviced as follows: Air filter element replacement Change oil Change oil filter Replace Belts one time per year Replace unloader diaphragms one time per year Inspect dryer- air clean exterior of condenser with compressed air Check temps/ pressures Check drain trap operations Powerex Systems will be serviced as follows: Change air filters one time per year Change floats in water separators Change line filter element and floats Change belts Change dryer exhaust filters two times per year Change HC elements once per four years The Rotary screw compressors and vacuum pumps will be serviced as follows: Oil sample taken Change oil filters Replace Separators (Every 4000 hours of operation) Check belts (Change belts every 4000 hours of operation) Change air filter elements Check safeties Clean Exterior of coolers with compressed air Clean entire unit Airtec Vacuum Pumps will be serviced as follows: Change water filters two times per year Change air filter elements two times per year Dryers- install overhaul kits and desiccant (every 2 years) Three emergency (after hours) callouts for labor only Six dew point probes to be on a two-year calibration schedule Parts Contractor shall include a list of all parts covered by Preventive Maintenance with the cost mark up. Contractor shall provide the cost mark up for parts not included in the Preventive Maintenance. Additional Equipment Additional equipment may be added or existing equipment removed from the list when necessary to meet the changing needs of the facility which may be required throughout the life of the contract and shall be considered within the scope. Written Reports Written reports for the work completed and recommendations on repairs shall be required with a cost quote included after each PM and/or service call. Emergency & Repair Service Work The contractor will be required to provide 24/7 response to emergency air compressor and vacuum pump system problems. Response time will be with-in 2 hour time frame. The contractor will provide a straight time hurly rate and an overtime hourly rate for emergency call-ins and routine repair service. In the event of a major breakdown a suitable rental must be available within 24 hours. Performance Work Statement Tasks The contractor shall be available to perform the semi-annual preventive maintenance on a schedule that is satisfactory to the hospital. The contractor shall work continuously on preventive maintenance once the work has started until all the units specified in the contract are completed. The contractor shall provide legible and complete reports on all equipment that received preventive maintenance including the repairs required and a cost proposal to perform the repair. The contractor shall respond to all emergency repair call ins within the 2 hour time frame specified. The contractor shall provide highly qualified technicians with adequate training to resolve all repair issues encountered. Infectious Control The Contractor shall conform to the infection control measures as specified in the attached Construction Specification for Infection Control. Preventive Maintenance Service will normally but not always is performed in a separate work area not subject to all the infection control procedures. Repairs and emergency repairs may be conducted in patient rooms and other hospital areas that are subject to infection control encountered. Work Hours and Project Sequence Routine PM and repair work can start as early as 7:00am and work past 4:30pm week days. Weekend work needs to be approved by the Mechanical Maintenance Supervisor. Emergency service work will occur as conditions dictate. Duration This service contract will be for a Base Year and four (4) one (1) year options renewable at the discretion of the VA. COR: Euel Sims, Mechanical Maintenance Supervisor NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (20-JUN-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/WHVAMC/VAMCCO80220/36C24119Q0268/listing.html)
- Place of Performance
- Address: Department of Veterans Affairs;Connecticut HCS;West Haven Campus;950 Campbell Avenue;West Haven, CT
- Zip Code: 06516
- Country: USA
- Zip Code: 06516
- Record
- SN05347267-F 20190622/190620230018 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |