Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 08, 2019 FBO #6406
SOURCES SOUGHT

65 -- Vein Viewer

Notice Date
6/6/2019
 
Notice Type
Synopsis
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;VISN17 Network Contracting Activity;7400 Merton Minter Blvd. (10N17/90C);San Antonio TX 78229
 
ZIP Code
78229
 
Solicitation Number
36C25719Q0894
 
Response Due
6/11/2019
 
Archive Date
6/26/2019
 
Point of Contact
JESUS.CASIANO@VA.GOV
 
Small Business Set-Aside
N/A
 
Description
134 VeinViewer Vision2 User Guide 020-101077-05 Rev. 1 (02-2016) ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 2.00 EA $0.00 $0.00 VEIN VIEWER VISION2 WITH MAX REACH HEAD TO TOE IMAGING WITH 5 YEAR WARRANTY. LOCAL STOCK NUMBER: 134-003104-01 GRAND TOTAL $0.00 This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of businesses including (but not limited to) 8(a), HUBZone, Service Disabled Veteran-Owned Small Business, and Veteran-Owned Small Business firms relative to the North American Industry Classification Code (NAICS) 336112. The Department of Veterans Affairs is seeking both manufacturers and/or distributors of the exact match or functionally equivalent equipment/ services to the following listed above with a suspense date of Tuesday, 06/11/2019 at 3pm CST. Nursing Vien viewer - Statement of Work (SOW) Project Description: To purchase Vein Viewer to support new infusion clinic and inpatient med surg unit. Specifications: Viewer: Weight (assembled device) Not to exceed 54 lbs Height (assembled device) Not to exceed 69.8 in Basket Weight Limit Hold a minuim of 0.5 lbs Power Rating Input (AC Mains): 100-240 VAC, 50/60 Hz, 25W, 0.45A at 115VAC typical and 0.3A at 230VAC typical Input (Battery): 9V DC, 1.42A Maximum Equipment Protection Class: Class II (AC Power Cord) Battery Rechargeable Battery Pack IR Wavelength, peak Approximately 850 nm Visible Wavelength, peak Amber LED: 617 nm Green LED: Approximately 525 nm Blue LED: 465 nm Technical Specifications Battery Duty Cycle Continuous Operating Temperature +60 °F to +86 °F (+16 °C to +30 °C) Storage Temperature -10 °F to +140 °F (-23 °C to +60 °C) Storage Humidity 0% to 90% non-condensing Atmospheric Pressure (storage and operating) 700 hPa to 1,060 hPa Humidity (storage and operating) 10% to 90% non-condensing Safety Has been tested to and complies with General Requirements for Safety per IEC 60601-1. Compliant with IEC 60601-1 National differences for: Austria, Belgium, Canada, Switzerland, Czech Republic, Germany, Denmark, Finland, France, United Kingdom, Hungary, Israel, Italy, Japan, Netherlands, Norway, Poland, Sweden, Singapore, Slovakia, Slovenia, Turkey, Ukraine, United States. Emission Has been tested to and complies with IEC60601-1-2 standard for Electromagnetic Compatibility (EMC) and for radiated and conducted emissions. EMC Classified A Regulatory Classified FDA Class 1 Exempt LED Radiation Class 1 LED Product as per IEC 60825-1 ED. 1.2 (2001) LED maximum output: 523nm (A1) = 1.60 mW 875nm (A2) = 1.778mW Equipment Classification classification as a medical device. Class II or Internally Powered Equipment. Protection Against Ingress of Liquids - Ordinary. Mode of operation of equipment - Continuous Operation. Stand: Wheeled stand for hands-free use of Vein viewer. Minuin 5 prong/leg base for stand s stable base and smooth gliding wheels. Arm, to allow for vien viewer to be precisely positioned to keep the selected vein highlighted. Arm extended and flexible reach must allow the patient can be easily accessed with User and Service Manuals: The vendor shall provide a complete printed sets as well as electronic version of operator manuals, service manuals, electronic schematics, troubleshooting guides and parts list for each bladder scan purchased for each medical center. These manuals will include all components and subassemblies, including those not manufactured by the vendor. Provide a manual or reference guide for how equipment should be cleaned and disinfected. Information System Officer, Information Protection: The contractor will not have access to VA Desktop computers they will not have access to online resources belonging to the government. Privacy Officer: The Contractor will not have access to protected Patient Health Information (PHI) nor will they have capability of accessing patient information during the services provided to the VA and if removal of equipment from the VA is required, any memory storage device will remain in VA control and will not be removed from VA custody. All research data available for Contractor analysis is de-identified. Records Manager: Records Manager:   There will not be federal records created, maintained, used or dispositioned with this contract;   regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.] NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (06-JUN-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/VASTHCS/VASTHCS/36C25719Q0894/listing.html)
 
Place of Performance
Zip Code: 78229
 
Record
SN05333382-F 20190608/190606230024 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.