Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 22, 2019 FBO #6328
SOURCES SOUGHT

45 -- 36C249-19-AP-1381 Self- Contained Trash Compactor w/Hydraulic Ram

Notice Date
3/20/2019
 
Notice Type
Synopsis
 
NAICS
333318 — Other Commercial and Service Industry Machinery Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 9;1639 Medical Center Parkway;Suite 400;Murfreesboro TN 37129
 
ZIP Code
37129
 
Solicitation Number
36C24919Q0207
 
Response Due
3/25/2019
 
Archive Date
4/9/2019
 
Point of Contact
chaz.bowling@va.gov
 
Small Business Set-Aside
N/A
 
Description
Page 1 of 2 Request for Information-Sources Sought Notice 36C24919Q0207 This is a Request for Information (RFI) to conduct market research to determine the availability of vendors capable of providing the requirement for two Self-Contained Trash Compactor with Hydraulic Ram. The Trash Compactors are needed for the Mountain Home VAMC to replace the current equipment. This RFI does not guarantee the issuance of an RFQ. If you have the availability to provide the requirement, please respond to this RFI with a capabilities statement. This RFI is issued solely for information and planning purposes. It does not commit the Government to contract for any supply or service whatsoever. The VA is not, at this time, seeking proposals and will not accept unsolicited proposals. Responders are advised that the U.S. Government will not pay for any information or administrative costs incurred in response to this RFI; all costs associated with responding to this RFI will be solely at the interested vendor s expense. Not responding to this RFI does not preclude participation in any future RFQ, if any is issued. Any information submitted by respondents to this RFI is strictly voluntary. All submissions become Government property and will not be returned. Requirement The James H. Quillen VA Medical Center requires two Self-Contained Trash Compactor with Hydraulic Ram. Equipment: Part Number Description Quantity Building 205 Compactor Self - contained trash compactor with hydraulic ram 1 Building 160 Compactor Self - contained trash compactor with hydraulic ram Enclosure rear dock, feed with barn doors and interlocks with a dock height of 48 1 Misc Delivery, Installation, Training, Maintenance Training, One-year warranty on provided equipment 2 General description:   Compactor, self-contained, complete with power unit 3- phase power, Tri-voltage Option preferred one of which Must be 480 volts, Container Full and 80% full warning lights, remote push buttons on 15 cord, multi-cycle timer, auto counter start, ¼ rail understructure, Container section at least 7 Gauge floor, Walls & top, compactor head section ½ floor and ¼ walls, Hydraulic Hose protectors.   Building 205 low opening fits Building 160 loads from dock General Drawing of both with under our trash chute with barn doors measurements in inches Salient Characteristics: Building 205 Compactor Standard Specifications must meet or exceed: Discharge Opening- 37.2" X 60  to 41 x 58 6"X 2" x ¼ long sills 4 X 6" Solid Steel Nosecone rollers with I/4 Plate brackets 3" Structural channel Crossmember on 16" Centers 8" dimeter X 10" long front and Rear ground rollers 7 Gauge floor, roof, front sheet, side sheets, read door sheet Clear opening 37.2" X 60" Cycle time 39 Seconds Total normal force 39566 pounds Total Maximum force 43964 pounds Ram penetration 11 inches Motor 10 HP Pump 12 GPM Normal Hydraulic pressure 1800 psi Maximum Hydraulic Pressure 2000 psi Cylinder Stoke 37 inches Cylinder Bore (Dual Cylinder) 4 inches Cylinder rod (dual Cylinders) 2 inches Hydraulic reservoir Capacity 25 gallons Primed and Pained any Standard Color 1-year warranty, two copies of maintenance and operator manuals Disposal and removal of old unit after empty and free of trash, Hauling/Freight offload, set-up and test. Building 160 Compactor The compactor for building 160 must meet all the above and include:   (Load option description), enclosure rear dock; Feed with barn doors and interlocks with a dock height of 48 to 54 actual height is 54. 1-year warranty, two copies of maintenance and operator manuals Disposal and removal of old unit after empty and free of trash.   Hauling/Freight offload, set-up and test Please note that requirements defined to date may change before a final solicitation is released. RFI requirements are as follows: Please acknowledge if your company is an authorized provider of the Varian Servers and support services. Submit responses and related information via email to chaz.bowling@va.gov by 11:00 AM CST, March 25, 2019. Proprietary/Confidential material shall be clearly marked on every page that contains such. Include the name, phone number, and email address of the lead from your organization. VA reserves the right not to respond to any or all emails or materials submitted. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (20-MAR-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/NaVAMC/VAMCCO80220/36C24919Q0207/listing.html)
 
Place of Performance
Address: Department of Veterans Affairs;James H Quillen VA Medical Center;Corner of Lamont & Veterans Way;Mountain Home
Zip Code: 37684
Country: USA
 
Record
SN05255113-F 20190322/190320230019 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |