Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 10, 2019 FBO #6257
SOLICITATION NOTICE

69 -- NURSING ANNE SIMULATOR EQUIPMENT

Notice Date
1/8/2019
 
Notice Type
Synopsis
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 4
 
ZIP Code
19104
 
Solicitation Number
36C24419Q0214
 
Response Due
1/11/2019
 
Archive Date
3/12/2019
 
Point of Contact
Rashaun Thomas
 
Small Business Set-Aside
N/A
 
Description
FedBizOpps Presolicitation Notice * * * * * * * CLASSIFICATION CODE SUBJECT CONTRACTING OFFICE'S ZIP-CODE SOLICITATION NUMBER RESPONSE DATE (MM-DD-YYYY) ARCHIVE DAYS AFTER THE RESPONSE DATE RECOVERY ACT FUNDS SET-ASIDE NAICS CODE CONTRACTING OFFICE ADDRESS POINT OF CONTACT (POC Information Automatically Filled from User Profile Unless Entered) DESCRIPTION See Attachment AGENCY'S URL URL DESCRIPTION AGENCY CONTACT'S EMAIL ADDRESS EMAIL DESCRIPTION ADDRESS POSTAL CODE COUNTRY ADDITIONAL INFORMATION GENERAL INFORMATION PLACE OF PERFORMANCE * = Required Field FedBizOpps Presolicitation Notice Rev. March 2010 69 NURSING ANNE SIMULATOR EQUIPMENT 19104 36C24419Q0214 01-11-2019 60 N 339112 Department of Veterans Affairs Network Contracting Office 4 Rashaun Thomas VA Pittsburgh healthcare System 15240 Rashaun.thomas@va.gov Contract Specialist Page 3 of 8 VETERANS AFFAIRS MEDICAL CENTER, PITTSBURGH, PA GENERAL INFORMATION FOLLOWED BY A TENTATIVE STATEMENT OF WORK NOTICE: This is not a solicitation but rather a Request for Information (RFI) (Sources Sought) to determine capability of potential sources and is for information and planning purposes only. Veterans Health Affairs, Network Contracting Office 4, is issuing this request for information/sources sought notice in order to identify capable firms to provide Nursing Anne Simulators, Brand Name or Equal for the Pittsburg, PA VA Medical Center. The units must be rated for commercial use and within hospital specification standards. This sources sought is brand name or equal. Responses must be submitted by COB January 11th, 2019 by 12:00PM Eastern Standard Time (EST). Submit responses to the information requested above via email to rashaun.thomas@va.gov. All SDVOSB and VOSB firms that respond shall include proof of CVE certification via www.vip.vetbiz.gov. All small business firms that respond shall include proof of small business status via their Representations and Certifications in accordance with (FAR 4.1102 Policy). All firms that respond must be registered in the System for Award Management via https://sam.gov/SAM/. All firms who respond must submit their Duns & Bradstreet number via https://www.dnb.com/. Any firms holding an GSA schedule contract from https://www.ebuy.gsa.gov/advantage/ebuy/start_page.do must submit the GSA contract number. All firms who respond must submit their tax ID number. While SDVOSB/VOSB contractors are preferred, all capable contractors are welcome to respond to this source sought notice for market research purposes, and shall include as part of their response a brief capability statement that covers the information in the following tentative statement of work. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., socioeconomic set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses. This sources sought will accept any recommendations for Product Service Code or NACIS codes. STATEMENT OF WORK Objectives: The overall goal of simulation is to provide education and deliberate practice opportunities to the learner in a safe, non-judgmental learning environment. The Nursing Anne simulator supports nursing education and training in the following areas; orientation, health assessment, medical surgical skills and team training, annual competency assessment, and nutrition. The Nursing Anne Simulator specifications include and shall adhere to the following requirements: Medication Administration of eardrops Oral via NG tube Bilateral pre-ported IV arms with capability for intravenous bolus or push through intravenous infusion when attached to a fluid bag Optional female multi-venous IV training arm with capability of IV cannulation placement Bilateral deltoid, ventral gluteal, dorsal gluteal and thigh injection sites Palpable anatomy to aid in site selection includes anterior superior iliac crest, pubic symphysis and greater trochanter Vaginal canal allows for insertion of vaginal suppositories or medications Anal opening will accept real and simulated rectal suppositories Hygiene: Wig for hair care procedures Ear canal for practice of irrigation and cleaning Oral care and hygiene Removable upper denture for oral and denture care Bed baths and skin care Patient simulator shall allow manipulation into dorsal recumbent position for perineal care Perineal care, including separation of the labia for cleansing Skin Integrity and Wound Care: Patient positioning for prevention of pressure ulcers Bandage and binder application Nasal packing Dressing and dressing changes Toes spread for bandaging Patient Handling: Full articulation for realistic patient handling procedures Head can be flexed into chin to chest position and remain flexed until repositioned Sits unassisted and bends at waist to tripod position Protective positioning Patient transfer techniques Range of motion exercises Nutrition: Accurate anatomical landmarks for insertion of NG Tube to correct measurement (nose to earlobe to xiphoid process) Lavage and gavage Invisible port in upper left abdomen for pre-placement of a PEG or J tube for feeding Internal reservoir with 500mL fluid capacity, external quick fill port, and optional external bag for large volume feeding. Urinary Elimination: Female genitalia with realistic anatomy, includes labia majora, labia minora, urethral opening, clitoris, and vagina Labia minora in naturally closed position, when opened exposes urethral opening Manipulation into supine position with knees flexed is possible Genitalia accepts straight or indwelling catheters Genitalia attaches to an internal system including an internal urinary reservoir for urinary catheterization with ability to pressurize reservoir for proper fluid return Intermittent closed catheter irrigation Urinary reservoir has external quick access port for ease in filling Bowel Elimination: Manipulation into Sims position for enema administration possible Genitalia attaches to external reservoir bag for enema administration Anal opening will accept real and simulated rectal suppositories Ascending colostomy stoma with through hole connects to fluid reservoir for irrigation procedure Three interchangeable stomas, include normal, dusky (non-perfusing), and infected Changing and emptying ostomy appliance Bowel Sounds: Four independently controlled auscultation areas for bowel sounds, centered around the umbilicus Volume control in each quadrant Bowel sounds are continuous repetitive sounds repeated infinitely: Normal, Hyperactive, Borborygmus, Hypoactive, No Sound Oxygenation & Perfusion: Realistic airway with uvula, epiglottis, vocal cords and esophagus Various oxygen delivery methods with visible chest rise including nasal cannula, masks, trach collar/mask, CPAP device Bag-mask ventilation Suctioning (Oral & Nasopharyngeal) Concealed port in neck for insertion of tracheostomy tube Trach care tracheal suctioning with fluid Ventilations with chest rise Lung Sounds: Anterior and posterior lung sounds synchronized with the set breathing rate (0-60 bpm) and chest rise on the manikin: Normal, Coarse crackles, Fine crackles, Pleural rub, Pneumonia, Rhonchi, Stridor, Wheezes, No Sound Lung sound and sound volume may be set individually for each lung left and right, upper and lower Anterior and posterior lung sound auscultation sites Heart Sounds: Synchronized with the ECG (QRS): Normal, Aortic stenosis, Austin Flint Murmur, Friction Rub, Mitral Valve Prolapse, Systolic Murmur, Diastolic Murmur, OS@70ms / Open Snap MS Non-perfusing rhythms will not generate heart sounds Resuscitation: CPR Capable Oral/Nasal Intubation Supraglottic Airway Insertion BVM Ventilation Head tilt/Chin lift Jaw thrust w/articulated jaw Sellick s Maneuver Chest compressions with maximum compression depth of 70mm ECG monitoring capabilities when used with SimPad PLUS, SimPad Classic or LLEAP, and ShockLink Defibrillation, cardioversion and pacing when used with ShockLink (training pads apex and sternum) Fluid, Electrolyte, and Acid-Base Balance: Invisible port below the clavicle for pre-placement of central line catheter for site care, dressing change, flushing lines, and continuous or intermittent infusion Internal central line reservoir with 500mL fluid capacity, with option to use an external reservoir bag for large volume infusions Fluid, Electrolyte, and Acid-Base Balance: Invisible port below the clavicle for pre-placement of central line catheter for site care, dressing change, flushing lines, and continuous or intermittent infusion Internal central line reservoir with 500mL fluid capacity, with option to use an external reservoir bag for large volume infusions Operation: Completely wireless and self-contained Internal electrical and pneumatic power Supplemental wired connectivity and power Wirelessly integrates with existing computer networks SimPad System (backwards compatible) SimPad PLUS System Laerdal Learning Application - LLEAP The contractor will provide the simulator and installation of said simulator and installation of software and licenses. B.3 TECHNICAL SPECIFICATIONS Nursing Anne Simulator Completely wireless and self-contained Internal electrical and pneumatic power Supplemental wired connectivity and power Wirelessly integrates with existing computer networks SimPad System (backwards compatible) SimPad PLUS System Laerdal Learning Application - LLEAP o Tablet PC Instructor Patient Monitor, Rugged Table Instructor PC Patient Monitor, Laptop LLEAP Instructor PC Patient Monitor, All-in-One Panel PC Instructor-Patient Monitor Wireless Headset Nursing Anne Simulator Specifications Size and Weight Dimensions (Patient Simulator only) 170 cm (5 7 ) Weight (Patient Simulator only) 31.75 kg (70 lbs) Patient Simulator Power External Power 12VDC, 3.3A Internal Battery 14.52 V, 5.2 Ah, 76Wh Battery Time 6 hours (default settings) Temperature Limits Operating Temperature 10 °C to 40 °C (50 °F to 104 °F) Storage Temperature -15 °C to 50 °C (5 °F to 122 °F) Battery Charging 19 °C to 30 °C (66 °F to 86 °F) Environment - Patient Simulator Only Relative Humidity 20% - 90% (non-condensing) RF Communication WLAN Frequency Ranges 2.4 GHz WLAN 5 GHz WLAN WLAN Operation Range 100 m (300 ft) outdoors Pressure Data (Compressor) Working Pressure 1.5 bar Working Temperature 0 ºC to 40 ºC (32 ºF to 104 ºF) Capacity of the vessel (V in l) 0.3 l Material Chart for Patient Simulator Clothes Cotton, Polyester Skins and airways Silicone, PVC (DEHP free) External hard plastics PP, PA, PC, PC/PET, PVC, ABS Inner plastics Silicone, TPU, TPE, PVC, Nitrile PA, PA+GF, PC, ABS, POM, HDPE, PET Metal components Aluminium, Brass, Steel End of Document NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (08-JAN-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/36C24419Q0214/listing.html)
 
Place of Performance
Zip Code: 15240
 
Record
SN05188936-F 20190110/190108230013 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.