SOLICITATION NOTICE
66 -- Transdermal Fluorescence Detector and Excitation Devices
- Notice Date
- 1/6/2019
- Notice Type
- Combine Synopsis/Solicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Contracts Management Branch 6710B Rockledge Dr., Suite 1124, MSC7000 Bethesda MD 20892-7510
- ZIP Code
- 20892-7510
- Solicitation Number
- 75N94019Q00010
- Response Due
- 1/14/2019
- Archive Date
- 1/15/2019
- Point of Contact
- Verne Griffin, Business Opportunity Specialist, Phone 301-594-7730
- E-Mail Address
-
verne.griffin@nih.gov
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation and a separate written solicitation will not be issued. This solicitation number is RFQ-75N94019Q00010 and is issued as a Request for Quotation (RFQ). The solicitation /contract will include all applicable provisions and clauses in effect through Federal Acquisition Circular 2005-99. The North American Industry Classification (NAICS) Code is 344516 with a size standard of 500. This acquisition is being conducted using Simplified Acquisition Procedures in accordance with FAR Part 13. The National Institutes of Health (NIH), National Institute of Digestive, Diabetes & Kidney Diseases (NIDDK) has a requirement to procure Transdermal Fluorescence Detector and Excitation Devices.. The miniaturized instrument is built from four light-emitting diodes with an emission maximum for MB-102 at 450 nm (channel 1) and for MB-404 at 500nm (channel 2). The photo diodes detect the fluorescent light with a maximum sensitivity peak at 560 nm for MB-102 and at 580nm for MB-404. To select the appropriate wavelength for channel 1, three filter layers are placed in front of the photodiode (767 Oklahoma Yellow; 500 nm; Lee Filters). Optical properties for Channel 2 can be adjusted using optical filtration if necessary. After highly sensitive amplification and digitization (10 bit), the data is stored in the internal memory of the micro-controller. After the measurement the data set is downloaded to a PC (via USB), where the kinetic parameters are determined. The energy for the device is supplied by a small lithium polymer rechargeable battery (201212 from General Electronics Battery Co., Ltd.). NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (06-JAN-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/HHS/NIH/NICHD/75N94019Q00010 /listing.html)
- Record
- SN05187845-F 20190108/190106230015 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |