MODIFICATION
D -- AMEND - SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A 1.0GB ETHERNET BETWEEN BLDG 166 RM 118, 7781 SPRINGFIELD JAMESTOWN RD, SPRINGFIELD, OH AND BLDG 23, RM 164, 3990 EAST BROAD STREET, COLUMBUS, OH.
- Notice Date
- 11/8/2018
- Notice Type
- Modification/Amendment
- NAICS
- 517311
— Wired Telecommunications Carriers
- Contracting Office
- Procurement Directorate - DITCO-Scott
- ZIP Code
- 00000
- Solicitation Number
- HC101318QA575
- Response Due
- 11/23/2018
- Archive Date
- 10/31/2019
- Point of Contact
- Edward Midkiff,;Angelina Hutson,618-229-9496
- Small Business Set-Aside
- N/A
- Description
- AMENDMENT 0003 IS ISSUED TO INCLUDE TECHNICAL INFORMATION PERTINENT TO THIS REQUIREMENT THAT MUST BE ADDRESSED IN QUOTES TO BE FOUND TECHNICALLY ACCEPTABLE. THESE TECHNICAL SPECS WERE NOT PART OF THE ORIGINAL SOLICITATION AND AMENDMENTS 0001 AND 0002. ALL QUOTES MUST BE REVISED TO ENSURE COMPLIANCE WITH THE ADDED SPECIFICATIONS: TELECOMM PROVIDER MUST PROVIDE TOTAL FIBER MILES AND ROUND TRIP DELAY (RTD) FROM THE CUSTOMER 'A' LOCATION TO THE CUSTOMER 'Z' LOCATION. THE RTD MUST BE AT 10MS OR BETTER. - VENDOR MUST PROVIDE LIGHT LEVEL READINGS (SIGNAL STRENGTH IN DBM) ON EXTENSION FROM COMMERCIAL POP TO GOVERNMENT SERVICE DELIVERY POINT (SDP) AT THE 'A' AND 'Z' LOCATION PRIOR TO CIRCUIT TURN OVER TO THE GOVERNMENT ENSURING LEVELS ARE WITHIN SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -3 TO -9 DBM. - VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO INSTALLATION AT THE 'A' AND 'Z' LOCATIONS. - VENDOR MUST CONTACT DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP UPON RECEIPT OF A VALID ORDER TO ESTABLISH THE COORDINATION AND ACTIVATION PROCESS. (C) 618-220-8627 (D) 770-8627 TESTING MUST BE SATISFACTORY PRIOR TO TURN OVER TO THE GOVERNMENT FOR ACCEPTANCE TESTING. TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564 (02/2016) ETHERNET SERVICE ACTIVATION - SIMPLE CIR VALIDATION TEST WITH EMIX PATTERN ADDFH. - ETHERNET FRAME SIZE MUSTBE CONFIGURED TO SUPPORT MAXIMUM TRANSMISSION UNIT (PHYSICAL MTU) OF 9100 OCTETS (BYTES) JUMBO FRAMES. MINIMUM TECHNICAL SPECIFICATIONS: SPECIFIC FORMAT TO BE USED IS: LINE RATE: 1.25 GIGABITS/S, +- 100 PPM LINE CODE: OPTIC 1. TEST AND ACCEPTANCE: 1GB ETHERNET CIRCUITS SHALL PASS A FULLY DOCUMENTED SATISFACTORY 72 HOUR SOAK TEST BY DISA GOC AT SCOTT AFB, IL. PRIMARY: (C) 618-220-8627 (D) 770-8627 2. TESTING PARAMETERS AND THRESHOLDS: THE FOLLOWING TESTING PARAMETERS SHALL BE MEASURED DURING TEST AND ACCEPTANCE TESTING. ERROR PERFORMANCE SHALL BE MEASURED AND RECORDED OVER THE DURATION OF A CONTIGUOUS 24 HOUR TESTING INTERVAL AND SHALL BE MEASURED AND RECORDED PER DEFINITION IN ITU-T-Y.1564. 3. ERROR PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN 99.5% OR BETTER. FRAME LOSS SHALL BE EQUAL TO ZERO WHEN TESTING AT 1.0 GIGABIT HIGHEST FRAME RATE, AND SHALL MEET ITU-T-Y.1564 STANDARDS. 4. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER THAN 24 HOURS. 5. ROUND TRIP DELAY (RTD): RTD SHALL BE MEASURED OVER THE 1GB CIRCUIT AND SHALL BE LESS THAN OR EQUAL TO 10 MILLISECONDS. 6. ROUND TRIP DELAY VARIANCE (JITTER) SHALL BE NO MORE THAN 3MS. ***** VENDORS MUST INCLUDE REQUESTED INFORMATION IN QUOTES, MAPS/BLOCK DIAGRAMS. VENDORS MUS VALIDATE QUOTES. EXPIRED QUOTES WITH MISSING AND INCORRECT INFORMATION WILL NOT BE EVALUATED. THE QUOTES DUE DATE IS EXTENDED TO 16 NOV 18. SERVICED ATE IS REVISED TO 01 APR 18.*****
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DISA/D4AD/DITCO/HC101318QA575/listing.html)
- Record
- SN05147279-W 20181110/181108230710-4fead68970b09e2a84a83147854fc957 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |