DOCUMENT
65 -- ArcCHECK 4D Isotropic Delivery QA - Attachment
- Notice Date
- 11/6/2018
- Notice Type
- Attachment
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 6;100 Emancipation Drive;Hampton VA 23667
- ZIP Code
- 23667
- Solicitation Number
- 36C24619Q0073
- Response Due
- 11/9/2018
- Archive Date
- 1/8/2019
- Point of Contact
- See Attachment
- E-Mail Address
-
cole.culley@va.gov
(cole.culley@va.gov)
- Small Business Set-Aside
- N/A
- Description
- Page 1 of 1 SOURCES SOUGHT: The Department of Veterans Affairs, VISN 6 Network Contracting Office (NCO) is conducting Market Research through this sources sought notice to help determine the availability of Businesses, registered under NAICS code 334510, capable of providing an 4D Isotropic Delivery QA to include the following components: 1220000-0Z ArcCHECK 4D Isotropic Arc Delivery QA Cylindrical detector array designed for rotational delivery QA and conventional IMRT QA, with 21cm in diameter and 21cm long. 1386 detectors, active area of 0.64mm ², update frequency of 50ms. Includes SNC Patient analysis software (Machine QA features are included, 25-meter power-data cable, USB cable, power supply (110/220 V), case, 1 year of hardware maintenance and 1 year of software maintenance. 1220000-1Z ArcCHECK ® CavityPlug Two piece PMMA (15 cm Diameter, 21 cm Length) cylindrical insert for ArcCHECK cavity. Outer plug accommodates range of inner plug options. Includes solid inner plug and single inner custom drilled plug of customer choice - please specify ion chamber type. If a vendor can provide an equal product, it must be equal to the ArcCHECK 4D Isotropic Arc Delivery QA. Additionally, the vendor shall provide detailed specifications for evaluation for proposed equal products. If the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered technically acceptable. The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than November 9, 2018, at 0700AM, EST to the attention of: Cole J. Culley, VA Medical Center, 27 Averill Avenue, Hampton, VA 23667. E-mail address: cole.culley@va.gov Please title all responses with the subject line: Sources Sought 36C24619Q0073: Active Breathing Coordinator Locations where deliveries are needed: VAMC Durham 508 Fulton Street Durham, NC 27705
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HaVAMC/VAMCCO80220/36C24619Q0073/listing.html)
- Document(s)
- Attachment
- File Name: 36C24619Q0073 36C24619Q0073.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4669428&FileName=36C24619Q0073-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4669428&FileName=36C24619Q0073-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C24619Q0073 36C24619Q0073.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4669428&FileName=36C24619Q0073-000.docx)
- Record
- SN05144799-W 20181108/181106231049-e59d139818749e3e90beeffd41778666 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |