SOLICITATION NOTICE
20 -- Booster Pump - Data Sheet - Salient Characteristics - Combined Synopsis Solicitation
- Notice Date
- 11/1/2018
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 333914
— Measuring, Dispensing, and Other Pumping Equipment Manufacturing
- Contracting Office
- Department of the Navy, Military Sealift Command, MSC Norfolk (N32205), Building SP-64, 471 East C Street, Naval Station Norfolk, Norfolk, Virginia, 23511, United States
- ZIP Code
- 23511
- Solicitation Number
- N3220519Q4362
- Archive Date
- 11/23/2018
- Point of Contact
- Samuel N. Queen, Phone: 7574435813
- E-Mail Address
-
Samuel.queen@navy.mil
(Samuel.queen@navy.mil)
- Small Business Set-Aside
- N/A
- Description
- Booster Pump/ See Salient Characteristics for more details. AMPCO ZC2-ZCH2 2' X 2' PUMP OR EQUIVALENTAPPLICATION DATAFLOW RATE: 64GPMTDH: 224NRSHR (FT): APPROX SPECIFIC GRAVITY: ASSUME 1.0TEMPERATURE: 60 DEGRESS FPUMP SELECTIONMATERIAL: NI/AL/BZASSEMBLY: CLOSE COUPLEDCONNECTION: # 150LB ANSI FLANGESPORT SIZES: 2' X 2'IMPELLER SIZE: 7.5'SEAL SELECTIONTYPE: T21 MECHANICAL SEALSIZE: 1.25'SEAT: CERAMICROTATING: CARBONELASTOMERS: BUNAMETALLICS: SSCOVER GASKET: LEXIDEMOTOR SELECTIONHP: 15HPFRAME: 254JMENCLOSURE: TEFCEFFICIENCY: PREMIUMRPM: 3500PH-HZ-VOLTAGE 3-60-230/460SF: 1.15MANUFACTURER: AMPCO (OR EQUIVALENT)ADDITIONAL MOTOR REQUIREMENTS:-SEVERE DUTY FEATURES TO MEET IEEE45-CAST IRON CONSTRUCTION-50 DEGREES C AMBIENT TEMPERATURE (MUST BE ON NAMEPLATE) -CONDUIT BOX EQUIPPED WITH TERMINAL BOARD -CLASS F INSULATION -115V SPACE HEATER WITH LEADS IN MAIN CONDUIT BOX -TEMPERATURE RISE CLASS BADDITIONAL PUMP REQUIREMENTS:-PROVIDE WITH JOHN CRANE MODEL 10 CYCLONE SEPARATOR IN MONEL CONSTRUCTION, AND FLUSH PIPING. CYCLONE SEPARATOR SHALL BE CAPABLE OF 5 MICRONS OR FINER SEPARATION -MOTOR BEARING LIFE EXPECTANCY 20,000 HOURS MINIMUM -MOTOR PROTECTION SHALL BE A MINIMUM OF IP23 -1/4'NPT VENT AND DRAIN CONNECTIONS ARE TO BE INCLUDED, CONNECTIONS SHALL BE DRILLED, TAPPED AND PROVIDED, WITH PLUGS.-1/8' NPT SUCTION AND DISCHARGE PRESSURE GAUGE CONNECTIONS ARE TO BE INCLUDED AT THE NOZZLES. CONNECTIONS ARE TO BE DRILLED AND TAPPED AND PROVIDED WITH PLUGS. Data Sheet AMPCO ZC2-ZCH2 2' X 2' PUMP OR EQUIVALENTAPPLICATION DATAFLOW RATE: 64GPMTDH: 224NRSHR (FT): APPROX SPECIFIC GRAVITY: ASSUME 1.0TEMPERATURE: 60 DEGRESS FPUMP SELECTIONMATERIAL: NI/AL/BZASSEMBLY: CLOSE COUPLEDCONNECTION: # 150LB ANSI FLANGESPORT SIZES: 2' X 2'IMPELLER SIZE: 7.5'SEAL SELECTIONTYPE: T21 MECHANICAL SEALSIZE: 1.25'SEAT: CERAMICROTATING: CARBONELASTOMERS: BUNAMETALLICS: SSCOVER GASKET: LEXIDEMOTOR SELECTIONHP: 15HPFRAME: 254JMENCLOSURE: TEFCEFFICIENCY: PREMIUMRPM: 3500PH-HZ-VOLTAGE 3-60-230/460SF: 1.15MANUFACTURER: AMPCO (OR EQUIVALENT)ADDITIONAL MOTOR REQUIREMENTS:-SEVERE DUTY FEATURES TO MEET IEEE45-CAST IRON CONSTRUCTION-50 DEGREES C AMBIENT TEMPERATURE (MUST BE ON NAMEPLATE) -CONDUIT BOX EQUIPPED WITH TERMINAL BOARD -CLASS F INSULATION -115V SPACE HEATER WITH LEADS IN MAIN CONDUIT BOX -TEMPERATURE RISE CLASS BADDITIONAL PUMP REQUIREMENTS:-PROVIDE WITH JOHN CRANE MODEL 10 CYCLONE SEPARATOR IN MONEL CONSTRUCTION, AND FLUSH PIPING. CYCLONE SEPARATOR SHALL BE CAPABLE OF 5 MICRONS OR FINER SEPARATION -MOTOR BEARING LIFE EXPECTANCY 20,000 HOURS MINIMUM -MOTOR PROTECTION SHALL BE A MINIMUM OF IP23 -1/4'NPT VENT AND DRAIN CONNECTIONS ARE TO BE INCLUDED, CONNECTIONS SHALL BE DRILLED, TAPPED AND PROVIDED, WITH PLUGS.-1/8' NPT SUCTION AND DISCHARGE PRESSURE GAUGE CONNECTIONS ARE TO BE INCLUDED AT THE NOZZLES. CONNECTIONS ARE TO BE DRILLED AND TAPPED AND PROVIDED WITH PLUGS.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/614dbf8c2c52986cdae3cfdec925d446)
- Record
- SN05140583-W 20181103/181101230751-614dbf8c2c52986cdae3cfdec925d446 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |