Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 04, 2018 FBO #6159
SOURCES SOUGHT

Y -- FOLSOM POWER PLANT HVAC & FIRE ALARM UPGRADES

Notice Date
10/2/2018
 
Notice Type
Sources Sought
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Bureau of Reclamation Mid-Pacific Region Regional Office Division of Acquisition Services 2800 Cottage Way, Room E-1815 Sacramento CA 95825-1898 US
 
ZIP Code
00000
 
Solicitation Number
DOIRFBO190001
 
Response Due
10/15/2018
 
Archive Date
10/30/2018
 
Point of Contact
Cabral, John
 
Small Business Set-Aside
N/A
 
Description
This announcement is to small business, 8(a) Small Business, HUBZone Small Business, Woman-Owned Small Business and Service-Disabled Veteran-Owned Small Business concerns that may be interested in performing a contract for the Mid-Pacific Region of the Bureau of Reclamation. The work to be performed is described below. Based upon response to this announcement, the Government may determine to set this acquisition aside or proceed with an unrestricted solicitation. The applicable North American Industry Classification System (NAICS) Code is 238220 and the related small business size standard is $15M. This notice is not a request for proposal and the information presented in this announcement will not obligate the Bureau of Reclamation in any manner. The estimated cost of this project is between $1,000,000.00 and $5,000,000.00. The work is located at Folsom Dam, City of Folsom, California in Sacramento County. Interested parties should include the following information in their response: (a) Business name, address, cage code, size classification based on NAICS size standard, socioeconomic classification (i.e. HUBZone and/or 8(a)), and a point of contact; (b) A positive statement of your intention to submit an offer for this solicitation as a prime contractor; (c) Evidence of your experience performing work similar in type and scope to the work in this announcement within the last five years. The evidence should include: contract numbers, project titles, dollar amounts and points of contacts with telephone numbers. Please do not include more than three past projects; and (d) Include attachments cataloging the company's equipment assets, personnel resources and financial resources that demonstrate company responsibility and capability to perform required work. All interested parties are encouraged to respond to this notice, by e-mail to jcabral@usbr.gov not later than 1:00 PM PST on 10/15/2018. The information provided in this announcement is all information the Government has available at this time. There are no specifications, drawings, bid packages, or source lists available. Prospective contractors MUST be actively registered in the System for Award Management (SAM) database at http://www.sam.gov to be eligible for award. PRINCIPAL COMPONENTS OF WORK A. Fire Alarm Systems: 1. Provide new fire alarm system for the following locations: a. Folsom Powerplant. b. Standby Generator Building. c. Cable Tunnel between Folsom Powerplant and Switchyard. d. Switchyard UHA Building. 2. Remove and dispose of existing fire alarm system components at locations where new fire alarm system is installed. B. Stairwell Ventilation Control: 1. Replace ventilation controls for Emergency Exit Stairs, shown in drawing 485-D-2249. 2. Remove and dispose of existing NSCP1 Fan Control Panel. C. HVAC: 1. Remove and replace existing 15-ton water-cooled heat pump with new 20-ton water-cooled heat pump. 2. Remove and replace one (1) 3-ton water cooled computer room cooling with two (2) 5-ton water-cooled computer room cooling units. 3. Refurbish all HVAC system components as described in 23 00 00 Heating, Ventilation and Air-Conditioning (HVAC). D. Fire Doors: 1. Remove and dispose the following: a. One (1) double swinging door, door frame, and associated hardware and features between rooms 204 and 207. b. One (1) single swinging door, door frame, and associated hardware and features between rooms 204 and 205. 2. Furnish and install the following: a. One (1) fire-rated double swinging door, door frame, and associated hardware and features between rooms 204 and 207. b. One (1) fire-rated single swinging door, door frame, and associated hardware and features between rooms 204 and 205. E. Lighting Replacement: 1. Provide new lighting system in identified areas and remove and dispose of existing system components at locations where new system is installed. F. Acoustical Ceilings: 1. Investigate acoustical ceiling system structural supports for compliance with applicable codes and standards. Design, furnish, and install new structural supports as required. Remove and dispose, and/or modify existing structural supports as required. 2. Remove and dispose the following: a. Ceiling panels, suspension systems, and associated features in the following rooms: 1) Floor El. 165.00: a) Toilet Room 301, Janitor Room 302, Control Room 303, Toilet Room 304, CVO Control Room 305, Computer Room 306, Locker Room 307, and Hallway adjacent to Rooms 301, 302, and 307 (no room number). 2) Floor El. 180.00: a) Lobby Room 401, Vestibule Room 402, Men ¿s Toilet Room 403, Janitor Room 404, Women ¿s Restroom Room 405, Women ¿s Toilet Room 406, Breakroom / Kitchen Room 408, Storage Room 409, Communications Room 410, Auditorium Room 411, and Unnamed Area adjacent to Rooms 401, 404, 408, 410, and 411 (no room number). 3. Design, furnish, and install the following: a. Ceiling panels, suspension systems, and associated features in the following rooms: 1) Floor El. 165.00: a) Toilet Room 301, Janitor Room 302, Control Room 303, Toilet Room 304, CVO Control Room 305, Computer Room 306, Locker Room 307, and Hallway adjacent to Rooms 301, 302, and 307 (no room number). 2) Floor El. 180.00: a) Lobby Room 401, Vestibule Room 402, Men ¿s Toilet Room 403, Janitor Room 404, Women ¿s Restroom Room 405, Women ¿s Toilet Room 406, Breakroom/Kitchen Room 408, Storage Room 409, Communications Room 410, Auditorium Room 411, and Unnamed Area adjacent to Rooms 401, 404, 408, 410, and 411 (no room number). G. Painting Walls: 1. Repair and paint walls in the following rooms: a. Floor El. 165.00: 1) Toilet Room 301, Janitor Room 302, Control Room 303, Toilet Room 304, CVO Control Room 305, Computer Room 306, Locker Room 307, and Hallway adjacent to Rooms 301, 302, and 307 (no room number). b. Floor El. 180.00: 1) Lobby Room 401, Vestibule Room 402, Men ¿s Toilet Room 403, Janitor Room 404, Women ¿s Restroom Room 405, Women ¿s Toilet Room 406, Breakroom/Kitchen Room 408, Storage Room 409, Communications Room 410, Auditorium Room 411, and Unnamed Area adjacent to Rooms 401, 404, 408, 410, and 411 (no room number). H. Miscellaneous Electrical and Control Work: 1. Miscellaneous electrical and control work to accommodate system modifications included in this contract. I. Work for identified scope items includes at minimum: 1. Field investigation of systems and drawings. 2. System design and analysis. 3. Demolition. 4. Installation. 5. Furnish equipment and components. 6. System programing. 7. Testing and Commissioning. 8. Training.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/150ab271969a8f98f67088eecde79a98)
 
Record
SN05112596-W 20181004/181002230459-150ab271969a8f98f67088eecde79a98 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.