DOCUMENT
66 -- 36C258-18-AP-0379 PRE Optometry Equipment CLIN 0002-EMERGENCY - Attachment
- Notice Date
- 9/19/2018
- Notice Type
- Attachment
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- 4135 South Power Road;Mesa,AZ 85201
- ZIP Code
- 85201
- Solicitation Number
- 36C25818Q9715
- Response Due
- 8/31/2018
- Archive Date
- 10/30/2018
- Point of Contact
- Columbus Campbell - 928-717-7548
- Small Business Set-Aside
- Veteran-Owned Small Business
- Description
- 1 NAVAHCS Statement of Work Specialty & Diagnostics Optometry Equipment The Northern Arizona VA Healthcare System has a need to replace aging optometry/ophthalmology equipment: This requirement is forTWO difference pieces of equipment that together provide a clinical evaluation solution and all will be connected via an interface to Vista Imaging. Retinal Camera, Optical Coherence a Visual Field Analyzer and software to manage data from three standalone analyzers. Software must retrieve images and data from the 3 analyzers to allow clinicians to view images/data at various workstations. The software must be able to provide the appropriate format for the images/data to be placed in the patient s medical record i.e. CPRS. The software must be able to be installed on a virtual server and DICOM conformant. Installation must be done by the manufacturer for warranty purposes. Training will also be conducted by manufacturer. Quantity one (1) Retinal Camera Specifications: Non-mydriatic Correctable optics with digital sensor Interfaceable Quick image transfer via network Integrated patient database, including multiple options for image comparison and review 24 or greater integrated Megapixel Sensor Auto-focus Advanced Positioning Small Pupil Mode 3.3 mm or less Built-in medical grade sensor for calibration for retinal images Advanced color separation filters including Fundus Auto Fluorescence filter to maximize views of Retinal Pathologies and diseases states. Quantity one (1) Visual Field Analyzer Specifications: Fixation Control Video eye monitor Blind spot monitor Gaze tracking Head tracking Vertex monitoring Visual field index: Summary measurement of the patient s visual field status, expressed as a percent of a normal age-adjusted visual field. Liquid trial lens: Using Liquid pressure, delivers each patient s refractive correction. Available correction range is -8 to +8 diopters. Spherical correction only. Smart Touch screen interface Fixation monitoring system to allow for systematic and pin point fixation inspection System that allows the doctor to compare visual field status and progression to data collected from glaucoma subjects and provide clinicians with statistically significant changes as well as rate of change to predict future vision quality - guided analysis. A system that provides a kinetic graphical interface with full 180degree testing range. Dimension: 46 L x 52 W x 58 H (cm) which is exactly equivalent to: 18.11 L x 20.47 W x 22.83 H (inch) Electrical Requirement: 100-120v- 50/60 Hz, 4.0A Internal Storage: 500 Gb Operating System: Windows 7-64 bit DICOM conformant Ability to import all raw data and algorithms of any previous Humphry Field Analyzer (HFA) into the instrument. Ability to combine multiple HFA databases from multiple instrument in clinic into 1 HFA database on the current server Ability to integrate and create a modality work list Information Security and Privacy considerations: Does the equipment store, transmit or print sensitive information? YES All new equipment, nothing refurbished. -4860 ext 3327 Deliver to: NAVAHCS 500 Highway 89N Prescott, AZ 86301 Warehouse, Bldg 20 Attn Rhonda Binaghi
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANAHCS649/VANAHCS649/36C25818Q9715/listing.html)
- Document(s)
- Attachment
- File Name: 36C25818Q9715 36C25818Q9715_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4599859&FileName=36C25818Q9715-001.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4599859&FileName=36C25818Q9715-001.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C25818Q9715 36C25818Q9715_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4599859&FileName=36C25818Q9715-001.docx)
- Record
- SN05096498-W 20180921/180919231128-44993fca1cd913efb7e1fe44699b883a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |