SOURCES SOUGHT
20 -- Fan Coil Units
- Notice Date
- 8/20/2018
- Notice Type
- Sources Sought
- NAICS
- 423730
— Warm Air Heating and Air-Conditioning Equipment and Supplies Merchant Wholesalers
- Contracting Office
- Department of Homeland Security, United States Coast Guard (USCG), USCG Surface Forces Logistics Center (SFLC), 2401 Hawkins Point Road, Building 31, Mail Stop 26, Baltimore, Maryland, 21226-5000, United States
- ZIP Code
- 21226-5000
- Solicitation Number
- 70Z04018Q6238Y00
- Archive Date
- 9/15/2018
- Point of Contact
- Kevin Lettich, Phone: 4107626725
- E-Mail Address
-
Kevin.j.Lettich@uscg.mil
(Kevin.j.Lettich@uscg.mil)
- Small Business Set-Aside
- N/A
- Description
- The Department of Homeland Security, United States Coast Guard (USCG) Surface Forces Logistics Center (SFLC) has a requirement providing material support in the form of fan coil units for multiple cutters at the US Coast Guard Yard Baltimore during a scheduled Midlife Maintenance Availability (MMA). All items must meet the specified item description and National Stock Number (NSN) contained in the solicitation package. 4130 01-464-3236 38450 V4 LVP-2.0KW-RH FAN COIL UNIT, NAVY STANDARD, V4, VERTICAL MOUNT, R.H. CONNECTIONS, NON-HI-SHOCK, MAGNETIC, SEALED MOTOR, 2.0 KW HEATER, LOW VOLTAGE PROTECTION, IN ACCORDANCE WITH MILPRF- 24775. OVERALL DEPTH 14 INCHES, OVERALL HEIGHT: 52 INCHES, OVERALL WIDTH: 36 INCHES, CASE MATERIAL STEEL, GALVANIZED, 24 COPPER TUBES, CONNECTION SIZE.625 INCHES IN OD. 4130 01-225-1077 38450 FCU-H4--2.0KW-LVP 38450 H4-LVP-2.0KW 38450 H420RP-G1 FCU H4 2.0 KW RH LVP FAN COIL UNIT, H4 NAVY STANDARD, HORIZONTAL MOUNT, R H. CONNECTIONS, NON-HI-SHOCK, 2KW HEATER, LOW VOLTAGE PROTECTION, IN ACCORDANCE WITH MIL-PRF-24775. OVERALL DEPTH 14 INCHES, OVERALL HEIGHT 52 INCHES, OVERALL WIDTH 36 INCHES. CASE METAL - STEEL GALVANIZED, COPPER TUBES, 24 TOTAL TUBES. CONNECTION SIZE:.625 INCHES IN OD. 4130 01-225-1085 38450 FCU-H3-1.75KW-LVP 38450 H3-LVP-1.75KW 38450 M24775-A3RH2A1 FAN COIL UNIT, NAVY STD, H3, HORIZONTAL MOUNT, R H. CONNECTIONS, NON-HI-SHOCK, 1.75KW HEATER, LOW VOLTAGE PROTECTION, IN ACCORDANCE WITH MIL-PRF-24775. OVERALL DEPTH 14 INCHES, OVERALL HEIGHT 52 INCHES, OVERALL WIDTH 27 INCHES. CASE MATERIAL: STEEL, GALVANIZED. 24 TUBES. CONNECTION SIZE:.500 INCHES IN OD. 4130 01-460-3377 38450 M-24775-A6RH(N/A) 1 38450 FCU-H6-0.0KW-LVP FAN COIL UNIT, NAVY STANDARD, H6, HORIZONTAL MOUNT, R.H. CONNECTIONS, NON-HI-SHOCK, MAGNETIC, SEALED MOTOR, NO HEATER, LOW VOLTAGE PROTECTION, IN ACCORDANCE WITH MIL-PRF-24775. OVERALL DEPTH 17 INCHES, OVERALL HEIGHT 52 INCHES, OVERALL WIDTH 39 INCHES, CASE MATERIAL STEEL, GALVANIZED, 32 COPPER TUBES, CONNECTION SIZE.625 INCHES IN OD. 4130 01-409-1423 38450 M-23798 B23XM 38450 DDG SZ23 TYIIIFCA FAN COIL UNIT, NAVY STANDARD, SIZE 23, TYPE III, NON-HI-SHOCK, 1EEE45 MARINE DUTY MOTOR, NO GRILLE, NO COVER PLATE, IN ACCORDANCE WITH MIL-PRF-23798, OVERALL DEPTH 32 INCHES, OVERALL HEIGHT 50 INCHES, OVERALL WIDTH 48 INCHES, CONNECTION SIZE 150# FLANGES IAW ANSI B16.24 CLASS 150 AND IAW DRAWING 225-WLB-514- 002 REV A. The Government anticipates making a single award for this effort. If you are claiming Small Business status, appropriate documentation is required. Please submit the following as it applies: a. If claiming 8(a) status, provide a copy of your 8(1) Certification from SBA. b. If claiming HUBZone status, provide a copy of your HUBZone Certification from SBA. c. If claiming SDVOSB status, provide documentation that shows a Service Disabled Veteran (SDV) unconditionally owns 51% of the business, controls the management and daily operations of the business, holds the highest officer position in the company, makes long-term decisions for the business and works at the business full-time during normal working hours. Documentation should also be provided to show that the SDV has a service-connected disability that has been validated by the Department of Defense, Department of Veteran Affairs. Finally, provide documentation that shows the business is small under the NAICS code 336611. d. If claiming VOSB status, provide documentation that shows the Veteran unconditionally owns 51% of the business, controls the management and daily operations of the business, holds the highest officer position in the company, makes long-term decisions for the business and works at the business full-time during normal working hours. The documentation should also show the business is small under the NAICS code 336611. e. If claiming EDWOSB status, provide documentation that shows the company is at least 51% owned by one or more women who are "economically disadvantaged" and primarily managed by an economically disadvantaged woman, controls the management and daily operations of the business, holds the highest officer position in the company, makes long-term decisions for the business and works at the business full-time during normal working hours. The documentation should also show the business is small under the NAICS code 336611. A woman is presumed economically disadvantaged if she has a personal net worth of less than $750,000 (with some exclusions), her adjusted gross yearly income averaged over the 3 years preceding the certification is less than $350,000 and the fair market value of all her assets is less than $6 million. f. If claiming Woman Owned Small Business (WOSB) status, provide documentation that shows the company is at least 51% owned and controlled by one or more women, controls the management and daily operations of the business, holds the highest officer position in the company, makes long-term decisions for the business and works at the business full-time during normal working hours. The women must be U.S. Citizens. The documentation should also show the business is small under the NAICS code 336611. g. If claiming Small Business status, provide documentation to show the business is small under. Concerns having the expertise and required capabilities are invited to submit complete and current information discussing their capabilities/past performance within 10 calendar days from the date this notice is posted. This is not a Request for Proposals; therefore, no pricing information shall be submitted at this time. Information shall be submitted via e-mail to the Contract Specialist, Kevin Lettich, at Kevin.J.Lettich@USCG.mil. The Government does not intend to pay for the information that is submitted. It is the responsibility of potential offerors to monitor this EPS system for future notices and changes. All responses will be considered by this agency.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/USCGELC/70Z04018Q6238Y00/listing.html)
- Record
- SN05046628-W 20180822/180820231554-f188ea16cf8b37e8b724431e040a33f3 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |