Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 22, 2018 FBO #6116
DOCUMENT

65 -- Power Injector - Attachment

Notice Date
8/20/2018
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;NETWORK 23 CONTRACTING OFFICE;Contract Officer;4801 Veterans Drive;St. Cloud MN 56303
 
ZIP Code
56303
 
Solicitation Number
36C26318Q9866
 
Response Due
8/27/2018
 
Archive Date
9/11/2018
 
Point of Contact
Wendy Hoeschen
 
E-Mail Address
wendy.hoeschen@va.gov
(wendy.hoeschen@va.gov)
 
Small Business Set-Aside
N/A
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), NCO 23- St Cloud is requesting procurement information for Medrad Mark 7 power injection system or equal for the Omaha VA Health Care System located in Omaha NE. The VA is in search of SDVOSB/VOSB organizations that are capable of servicing the Omaha VA Health Care System, Omaha NE s need to procure the following: The power injection system must meet the following needs: Small foot print for increased mobility, easy to position. Real time flow rate control to control contrast delivery across different procedure types including, CT, angiography, MRI, and Molecular imaging. Both fixed and variable flow rates with single injector system. Operator safety, ability to control injection procedure from a distance, reducing operator radiation exposure. Power Specifications: Flow Rates: 0.1-45.0 mL/s in 0.1 mL/s increments (single and phased) 0.1-59.9 mL/m in 0.1 mL/m increments (single mL/m) 1.0-10.0 mL/s in 0.1 mL/s increments (variable) Volume: 1-150 mL in 1 mL increments Pressure Limit (150 mL syringe): 100-1200 psi in 1 psi increments 689-8273 kPa in 1 kPa increments Rise Time: 0.0-9.9 seconds in 0.1 s increments Delay time: 0.0-99.9 seconds in 0.1 s increments Fill Speed: Manual 1-20 mL/s in 1 mL/s increments, Auto: 1-10 mL/s in 1 mL/s increments Fill Volume: 1-150 mL in 1 mL increments Syringe Size: 150 mL Protocol Memory: 39 Protocols (4 default, 35 storable) Injection Memory: Approximately 50 Injections Physical specifications: Ergonomic handle for easier maneuvering Front Load Syringe for easy insertion and clean removal Arc design for extended reach Pedestal style system with small footprint Sterile Hand Controller which allows for real-time control of flow rate Syringe and High Pressure Connecting System allows for one-handed connections
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/SCVAMC656/SCVAMC656/36C26318Q9866/listing.html)
 
Document(s)
Attachment
 
File Name: 36C26318Q9866 36C26318Q9866.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4551894&FileName=36C26318Q9866-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4551894&FileName=36C26318Q9866-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: 4101 Woolworth Ave;Omaha NE
Zip Code: 68105
 
Record
SN05045679-W 20180822/180820231220-ccfae391385207d1340baf831703faf4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers