DOCUMENT
H -- FY19 Base +4 Patient Overhead Lift QA Service - Attachment
- Notice Date
- 8/8/2018
- Notice Type
- Attachment
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- Anthony R. Mitchell;Department of Veterans Affairs;Overton Brooks VA Medical Center (90C);510 East Stoner Avenue;Shreveport LA 71101
- ZIP Code
- 71101
- Solicitation Number
- 36C25618U0210
- Response Due
- 8/16/2018
- Archive Date
- 9/15/2018
- Point of Contact
- Chris Nelson 228-523-4337 chris.nelson@va.gov
- Small Business Set-Aside
- N/A
- Description
- SOURCES SOUGHT SYNOPSIS DESCRIPTION: This Sources Sought Synopsis shall be used to determine the availability of potential sources having the skills and capabilities necessary to perform/provide Annual requirements for all patient overhead lifts and rail systems at Biloxi campus and CBOC s for the Gulf Coast Veterans Health Care System (GCVHCS), in accordance with the terms and conditions stated within the Statement of Work (SOW). Services shall be performed at 400 Veterans Ave., Biloxi, Mississippi, 39531-2410. All interested vendors are invited to provide information to contribute to this market survey/sources sought synopsis including, commercial market information. This is not a solicitation announcement. This is a Sources Sought Synopsis only. Questions should be submitted by email to anthony.mitchell4@va.gov. Provide only the requested information below. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hubzone, 8(a), small, small disadvantage, woman owned small business, or large business) relative to NAICS 811219 Precision equipment calibration (size standard of $20.5 million), PSC/FSC Code: H165 Quality Control Services/Medical, Dental and Veterinary. Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to sources sought synopsis, a solicitation announcement may be published on the FBO website. Responses to sources sought synopsis are not considered adequate responses to the solicitation announcement. All interested offerors must respond to the solicitation announcement in addition to responding to sources sought announcement. Please demonstrate the contractor's ability to perform services of this nature as the course of its daily business operations. Services shall be performed in accordance with industry standards and practices by qualified personnel. Responses must be emailed to anthony.mitchell4@va.gov no later than NOON CST, August 16, 2018. Your response should include both the STATEMENT OF CABABILITY and BUSINESS SIZE AND SOCIO-ECONOMIC STATUS information as explained below. Please place Attention: Patient Overhead Lift, in the subject line of your email. This notice is to assist the Veterans Affairs (VA) in determining sources only. A solicitation is not currently available; therefore, DO NOT REQUEST A COPY OF A SOLICITATION THAT DOES NOT EXISTS. If a solicitation is issued it will be announced later, and all interested parties shall respond to that solicitation announcement separately from the responses to this announcement. REQUESTED INFORMATION: (1) STATEMENT OF CABABILITY: (1) Submit a brief [five (5) pages or less] capability statement explaining your capability to perform required Annual Inspections and Weight Testing & Maintenance of 207 GH2 Ceiling Lift Systems and an additional 105 GH2 Trolley systems, at Gulf Coast Veterans Health Care System (GCVHCS) 400 Veterans Avenue Biloxi, MS 39531-2410, in accordance with the terms and conditions stated within this document. Include the number of qualified personnel needed to accomplish this service. Include experience in performing these services for the Veterans Affairs (VA), other Government (Federal or State) agency, or for a private medical facility. Please specify your maximum capacity and your availability to start. (2) BUSINESS SIZE AND SOCIO-ECONOMIC STATUS: Indicate whether your business is large or small If small, indicate if your firm qualifies as a small, emerging business, or small disadvantaged business If disadvantaged, specify under which disadvantaged group and if your firm is certified under Section 8(a) of the Small Business Act Indicate if your firm is a certified Hub zone firm Indicate if your firm is a woman-owned or operated business Indicate if your firm is a certified Service-Disabled Veteran Owned Small Business (SDVOSB) or Veteran Owned Small Business (VOSB) Include the DUNS number of your firm. State whether your firm is registered with the System for Award Management (SAM) at http://www.sam.gov and/or the VetBiz Registry at http://vip.vetbiz.gov/. If not, please NOTE: any future solicitation could only be awarded to a contractor who is registered in the System for Award Management (SAM). To receive award based on VOSB or SDVOSB status you must be registered in the VetBiz Registry. SPECIFIED REQUIREMENT: The contractor shall communicate its capabilities to accomplish the following: (See next page) 1. Contracting Officer s Representative (COR) or Point of contact (POC) information: Engineering, 400 Veterans Ave., Biloxi 228-523-4337 2. Contract Title: Patient Overhead Lift Weight Testing and Certification 3. Background: This is an ongoing Annual requirement for all patient overhead lifts and rail systems on Biloxi campus and CBOC s for the GCVHCS. 4. Scope. Perform required Annual Inspections and Weight Testing & Maintenance of 207 GH2 Ceiling Lift Systems and an additional 105 GH2 Trolley systems, in accordance with annual instructions and check list below. 5. Specifications/Characteristics: Annual Instructions for GH2 Ceiling Lift Inspection 1) Rail System. Inspect all bracket fixings to wall and/or ceiling, rails and stabilizers for tightness. Inspect and retighten the end-stops and make sure they are secure with roll pins. Inspect at all rail connections to ensure correct positioning of the rail connectors and pins. Find the label where the max capacity of the rail is stated and perform a weight test with similar weight. Hang the rated load of the rail system and drive it through the entire system while visually controlling that any bracket gives up to the weight. If the installation does not have the label, use the hoist capacity and the distance between supports as a guide and perform a weight test with a weight equivalent to 1.5 the selected max capacity for 5 minutes at each bracket locating the weight as close as possible to the bracket. If there is a combi-lock, switch track or turn-table in the installation, it should be considered as connecting to a second system and must be test accordingly. After the weight test Inspect level of the rail system with a laser or a box level at least 6 feet long. Mark the rail system with one label stating clearly the max capacity and the next inspection date. Inspect that the rated load of the hoist is less than or equal to the rated load of the rail system. 2) Electrical Connections. Inspect for broken wires, striped insulation and ground connection. Inspect that all cables are secured. 3) Hoist. Remove all covers and inspect all the snap rings and or E-clips between trolley and hoist. Remember snap rings must not be re-used; E-clips can be reused. Insure the strap is properly fitted to the shaft of the hoist and there is a locking ring securing the strap. To do this you must move the print base out of the way. Perform a full lifting cycle with the rated load of the hoist and listen any abnormal sounds from the hoist and that the hoist can lift the load without any problem. This is, going up all the way until the hoist stops by the end stop switch and going down until the hoist stops by the end stop down. While going up pull the string for the emergency stop and make sure the hoist stops. Do the same in the down direction. After the emergency stop and while the hoist is off, pull the emergency lowering string and make sure the hoist is lowering at a low speed. Place a sticker which includes the next inspection date and inspector initials. 4) Strap Inspect the whole length of the strap for frayed, hard spots, broken stitches, cut threads and deformations. Inspect the connection of the strap and the hanger. Make sure the Allen screws are tight, if applicable. 5) Lifting Hanger Inspect the welding and sling attachments points for cracks and deformations. Inspect the space between hanger and swivel and make sure the hanger in not wobbling. 6) Combi-Locks, if applicable Make sure the safety locks open and close easily manually and electrically whichever is applicable. Make sure they do not open while the traverse is not present. Inspect for corrosion. Inspect attachment to rail. After annual weight testing and inspection of the GH2 Installed Ceiling Lift systems, contractor must provide a completed checklist of items listed below. Annual Inspection Checklist 1) Rail System. Inspect and retighten all bracket fixings to the ceiling or wall. Inspect and retighten all bracket fixings the rails. Inspect and retighten all stabilizers. Inspect and retighten the end-stops and Inspect they are secure with roll pins. Inspect all rail connections for correct positioning and roll pins. Perform a weight test with a ________pound load. Inspect level of rail system. Mark the rail system with max load. Inspect that the rated load of the hoist is less than or equal to the rated load of the rail system. Place a sticker with the next inspection date. 2) Electrical Connections Inspect that all cables are secured. Inspect for broken wires Inspect for frayed insulation 3) Hoist Inspect all locking snap rings and or E-clips between trolley and hoist. Inspect the strap is properly fitted to the shaft of the hoist. Inspect the emergency stop. Inspect the emergency lowering. Perform a full lifting cycle with rated load. Place a sticker with the next inspection date. 4) Strap Inspect the entire length of the strap for damage or wear. Inspect the connection of the strap and the hanger. 5) Lifting Hanger Inspect welding areas as applicable. Inspect sling attachment. Inspect the space between hanger and swivel. 6) Combi-lock if applicable. Inspect the safety locks. Clean inside rails where safety locks are located (Mounted). Inspect that safety locks perform properly (i.e. Open and close easily both electrically and manually. Inspect for corrosion on the safety locks. Check the safety locks do not open when the traverse is not present. 6. Delivery. Prior to any work being completed the vendor will coordinate with Engineering Service or Machine Shop Supervisor for dates, times and locations.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/ShVAMC/VAMCLAOBrooks/36C25618U0210/listing.html)
- Document(s)
- Attachment
- File Name: 36C25618U0210 36C25618U0210.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4532975&FileName=36C25618U0210-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4532975&FileName=36C25618U0210-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C25618U0210 36C25618U0210.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4532975&FileName=36C25618U0210-000.docx)
- Place of Performance
- Address: Department of Veterans Affairs;Gulf Coast Veterans Healthcare System;Engineering;400 Veterans Avenue;Biloxi
- Zip Code: 39531-2410
- Zip Code: 39531-2410
- Record
- SN05026459-W 20180810/180808231058-1d97bae09b7c8a035f0eb5eb2f3e22d3 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |