47 -- Insulation Blankets - Attachment

Notice Date
8/7/2018
 
Notice Type
Attachment
 
NAICS
327993 — Mineral Wool Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 4;James E. Van Zandt VA Medical Center;2907 Pleasant Valley Blvd.;Altoona, PA 16602
 
ZIP Code
16602
 
Solicitation Number
36C24418Q9528
 
Response Due
8/14/2018
 
Archive Date
10/13/2018
 
Point of Contact
Jennifer Cutshall, Contract Specialist
 
E-Mail Address
Jennifer.Cutshall2@va.gov
(Jennifer.Cutshall2@va.gov)
 
Small Business Set-Aside
N/A
 
Description
The following is a Sources Sought/Request for Information notice. This posted notice is not a Pre-Solicitation or Solicitation document. The government is not currently soliciting bids, quotes or proposals at this time; however, reserves the right to do so at a later date. The VA Pittsburgh Healthcare System, University Drive Campus, Pittsburgh, PA, 15240 has a future requirement for removable insulation blankets for steam valves, pressure reducing valves, flash tank and strainers. The insulation blankets will provide energy savings and comply with safety standards for uninsulated steam components throughout the facility. Contractor will provide the entire identified component and valve blankets that meet the specifications for type, material, construction, affix/attach and fit. Contractor will provide delivery, installation and fitting services to completely install the insulation blankets at this site/facility. Contractor will provide as built drawings for replacement specifications. Contractor will provide specification and drawing submittals for approval. Site visit is required to determine proper measurements, typing, size and quantity. Removable Insulation Blanket Specifications - Applications Below 500 °F/260 °C GENERAL INFORMATION 1.1 Removable Insulation Blanket is for a Custom Designed Reusable Insulation System 1.2 Typical Applications for Removable Insulation Blankets include flanges, valves, pumps, instrumentation, manifolds, piping, exhausts, man ways, extruders, turbines, vessels and tanks. 1.3 All material specification is based on Manufactures Data Sheets and is provided without any liability to the customer 2.0 DESIGN 2.1 Removable Insulation Blankets are custom designed for each individual item 2.2 Material specifications are either specified by the contractor who will determine material specifications based on application and temperature rating. 2.3 A close contour fit is essential for proper thermal performance and neat appearance. Depending on size or weight the insulation blanket, may require multiple piece construction. 2.4 All fabrication drawings and specification are permanently maintained on file by the manufacturer for replacement or reoccurring orders. MATERIAL SPECIFICATION 3.1 HOT SIDE: Silicone Impregnated Fiberglass Fabric 17.5 Oz./Sq. Yd. Estimated Maximum Temperature: 500 °F/260 °C 3.2 INSULATION FILLER: Glass mat, type E needled fiber. 1 Thick, 9-11 LB/CF. Estimated Maximum Temperature: 1200 °F/648 °C 3.3 COLD SIDE: Silicone Impregnated Fiberglass Fabric 17.5 Oz./Sq. Yd. Estimated Maximum Temperature: 500 °F/260 °C 3.4 SEWING THREAD: PTFE/Teflon Impregnated Fiberglass Sewing Thread,.018 inches diameter. Estimated Maximum Temperature: 600 °F/315 °C 3.5 SECUREMENT: 1 304 Stainless Steel D-Ring and 1 Silicone Impregnated Fiberglass Fabric Straps with 1 HI AIR ® hook and loop for securement. Estimated Maximum Temperature: 350 °F/176 °C. Kevlar/Fiberglass knitted rope, diameter. Estimated Maximum Temperature: 380 °F/193 °C. 3.6 IDENTIFICATION TAG: 304 Stainless Steel, 1.5 x 3.5. 4.0 METHOD OF CONSTRUCTION 4.1 Sewn Construction is the method used for this application. Hog ring Construction is not applicable. 4.2 Double lock stitch with a minimum 6 to 8 stitches per inch. Blankets shall be sewn with two parallel rows using thread in section 3.4. 4.3 Materials in sections 3.1, 3.3 and 3.4 are sewn inside out and turned right side out before filling with insulation. All seams are inside stitches with the exception of the final closing seam will be an outside stitch. Insulation fillers 1- ½ or thicker will have a gusset, to ensure the full thickness throughout. 4.4 Longitudinal closers use a minimum 2 overlapping flap on the adjoining blanket section with a full length hook and loop strip oriented securement. All circumferential blankets shall use D-rings and Straps with hook & loop sewn on the tips. This application specified a knitted rope, in addition to standard securement methods. 4.5 Removable Blanket will have a permanently attached 1.5 x 3.5 SS Tag with embossed application or project information. QUANTITY AND DESCRIPTION: SPS STEAM STATION QTY SIZE DESCRIPTION 2 2-1/2 Valves With Bonnets 1 3 Valve With Bonnet 1 4 Valve With Bonnet 1 5 Valve With Bonnet 1 2-1/2 Strainer LOW PRESSURE DUEL STEAM STATION QTY SIZE DESCRIPTION 3 2-1/2 Valves With Bonnets 2 3 Valves With Bonnets 1 4 Valve With Bonnet 1 5 Valve With Bonnet 1 2-1/2 Strainer 1 3 Strainer 2 4 Strainers MEDIUM PRESSURE STEAM STATION QTY SIZE DESCRIPTION 1 4 Pressure Reducing Valve 2 3 Pressure Reducing Valves 2 2-1/2 Pressure Reducing Valves 2 3 Valves With Bonnets 1 4 Valve With Bonnet 1 6 Valve With Bonnet 1 10 Valve With Bonnet 1 4 Strainer 1 6 Strainer HIGH PRESSURE STEAM STATION QTY SIZE DESCRIPTION 1 2-1/2 Pressure Reducing Valve 1 3 Pressure Reducing Valve 1 3 Valve With Bonnet 2 4 Valves With Bonnets 1 5 Valve With Bonnet 2 6 Valves With Bonnets 2 4 Strainers 1 5 Strainer 1 6 Strainer 1 Flash Tank HOT WATER PUMPS QTY SIZE DESCRIPTION 12 4 Valves With Bonnets 3 4 Strainers 6 4 Expansion Joints MISC. QTY SIZE DESCRIPTION 2 5 Valves With Bonnets 1 6 Valve With Bonnet 1 8 Valve With Bonnet ALL INTERESTED PARTIES MUST ALSO HAVE AN ACTIVE REGISTRATION IN THE SYSTEM FOR AWARD MANAGEMENT (SAM) DATABASE. TO REGISTER, PLEASE VISIT WWW.SAM.GOV. Responses to this notice shall include a capability statement along with the following information : Company Name Address Point of Contact Phone Number Email Address DUNS Number CAGE Code Tax ID Number Note: In accordance with the U.S. Supreme Court decision regarding Kingdomware, service disabled veteran owned (SDVOSB) and veteran owned (VOSB), who are interested in this procurement and consider themselves to have the resources and capabilities necessary to provide these services shall be verified in VetBiz Registry as follows to be considered: http://www.vip.vetbiz.gov/ Process in 38 U.S.C. 8127(d) whereby a contracting officer of the Department shall award contracts on the basis of competition restricted to small business concerns owned and controlled by veterans, if the contracting officer has a reasonable expectation that two or more small business concerns owned and controlled by veterans will submit offers, and that the award can be made at a fair and reasonable price that offers the best value to the United States. For purposes of this VA specific rule, a service-disabled veteran-owned small business (SDVOSB) or a veteran-owned small business (VOSB), must meet the eligibility requirements in 38 U.S.C. 8127(e), (f) and VAAR subpart 819.7003 and be listed as verified in the Vendor Information Pages (VIP) database. Please provide answers to all questions below regarding your firm s Socio-Economic status pursuant to North American Industrial Classification Code (NAICS) 327993, Small business size standard 1,500 employees. 1. Is your business a small business under NAICS 327993? YES ______ NO ______ 2. Is your firm a Veteran-Owned Small Business? YES ______ NO ______ 3. Is your firm a Service-Disabled Veteran-Owned Small Business? YES ______ NO ______ 4. Is you firm a certified HUB Zone firm? YES ______ NO ______ 5. Is your firm a Woman Owned business? YES ______ NO ______ 6. Is your firm a Large Business? YES ______ NO ______ 7. What is your GSA Schedule Number? Schedule Number: ___________________ Expiration Date: _____________________ Please provide a capability statement as well as any relevant literature addressing your organizations ability to supply the required items. Also, please include a point of contact name, phone number and email address. Note: Questions regarding this notice should be addressed to Jennifer Cutshall via email only. Faxes and phone calls will not be accepted. Please submit all responses to this notice via e-mail to: Jennifer Cutshall Contract Specialist Jennifer.Cutshall2@va.gov Responses to this Sources Sought Notice are required by no later than Tuesday, August 14, 2018 at 12:00 pm EST.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PiVAMC646/PiVAMC646/36C24418Q9528/listing.html)
 
Document(s)
Attachment
 
File Name: 36C24418Q9528 36C24418Q9528.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4528745&FileName=36C24418Q9528-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4528745&FileName=36C24418Q9528-000.docx

 
File Name: 36C24418Q9528 36C24418Q9528 FBO Sources Sought.pdf (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4528746&FileName=36C24418Q9528-001.pdf)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4528746&FileName=36C24418Q9528-001.pdf

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN05025331-W 20180809/180807231731-4434acf3ba4cdfc0a6ab7e2862554564 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.