DOCUMENT

65 -- (C)(660) Optical Measurement System for Research - Attachment

Notice Date
8/2/2018
 
Notice Type
Attachment
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office;NCO 19;6162 South Willow Drive, Suite 300;Greenwood Village CO 80111
 
ZIP Code
80111
 
Solicitation Number
36C25918Q9775
 
Response Due
8/9/2018
 
Archive Date
10/8/2018
 
Point of Contact
Brooke Barker
 
Small Business Set-Aside
N/A
 
Description
This is a SOURCES SOUGHT request only. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The Government is NOT committed to award a contract pursuant to this announcement. This notice is published for market research purposes only. This notice is open to qualified business sources of all sizes. Information is sought regarding: The availability and capability of all qualified business sources; Whether qualified business sources are Service-Disabled Veteran Owned Small Businesses (SDVOSB) or Veteran-Owned Small Businesses (VOSB), small businesses, or large businesses; Vendor shall be and Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system such that the OEM warranty and service provided are maintained by the OEM. Provide verification when submitting quote; If the items are available via VA NAC, GSA Advantage, and/or open market; Size classification relative to the North American Industry Classification System (NAICS) code 334510 for the proposed acquisition. Requests for a solicitation will not receive a response. The purpose of this sources sought synopsis is to gain knowledge of potential qualified sources. The Government is seeking potential sources for the Optotrak Certus system described below or equal product(s). The equal item(s) shall meet or exceed the required item(s). For equal item(s): submit detailed documentation, (i.e. descriptive literature, specifications, illustrations, pictures) stating why/how the item(s) meet or exceed each brand name item (address all stated salient characteristics). All items shall be in a new, never used condition. Required items: PART # DESCRIPTION QTY 1 8800865 Optotrak Certus Position Sensor Full Focus. Includes: Optotrak Certus Position Sensor, Base Stand, and Communications Cable 7.62m 1 2 8801016 Optotrak Certus S-Type System Control Unit (SCU) with power cable. Wired control unit for Optotrak Certus with 3 strober ports, ethernet interface, and external synchronization port 1 3 8800949 USB interface kit. Connect Optotrak to a PC using USB 1 4 8800991 Optotrack Digitizing Kit. Includes: Digitizing Probe, Tool Strobe, and Strobe Cable 1 5 2401032 Ball Tip Fowler 1mm Test Indicator Ball Tip 2 6 800916 Optotrak Certus Smart Marker (pack of 5) 3 7 8700551.000.01.001 Smart Cluster Pre-built rigid bodies for Optotrak 12 8 7500633.004 Cable assembly Smart Marker interconnect Cable, 30cm (pack of 15) 1 9 7500633.005 Cable assembly Smart Marker interconnect Cable, 50cm (pack of 15) 1 10 8700497.000.01.001 Optotrak Certus Wireless Strober or equal. Use Smart Markers with Optotrak w/o being wired to the SCU 2 11 7500634.001 Cable Assembly Wireless Strober/Transmitter to SCU Interconnect Cable, 8m 2 12 7500635.001 Cable Assembly Wireless Strober to Battery Interconnect Cable, 30cm 1 13 8800747.001.003 Marker Strober Kit, S-Type, Optotrak Certus, boxed 1 14 7500547 Strober Cable S-Type, 8m 2 15 8800768 Cubic Reference Emitter Kit Certus. Use multiple position sensors in a common co-ordinate system 1 The Optotrak Certus will be used at the Salt Lake VA Medical Center Research Service. Laboratory mechanical testing of osseointegrated implant systems can be performed on systems like an MTS or Instron machine, and/or a FANUC robot, already in use by the Research Service. Each of those systems can move the work pieces and record the forces applied to them. An optical measurement system is required to add the ability to provide data on work piece displacement and deformation during testing. The Optotrak Certus system is plug-and-play with the existing mechanical testing systems within the Research Service. Custom software is already written to interface the Optotrak with an existing MTS, Instron and FANUC robot in the laboratory, to collect motion data synchronized to the respective mechanical system. Choosing another motion analysis system would require all fundamental control and data collection software to be rewritten for a different platform. This would halt the progress of experiments until new software could be written and validated for each machine. Responses due by Thursday, August 9, 2018 at 0800 Mountain Time to: brooke.barker@va.gov
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/36C25918Q9775/listing.html)
 
Document(s)
Attachment
 
File Name: 36C25918Q9775 36C25918Q9775.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4523800&FileName=36C25918Q9775-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4523800&FileName=36C25918Q9775-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN05017205-W 20180804/180802231016-298453b54c706eb90fc0c4303eaea62c (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.