H -- Annual certification of 48 Isolation rooms VAMC Memphis, TN - Attachment

Notice Date
7/28/2018
 
Notice Type
Attachment
 
NAICS
541380 — Testing Laboratories
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 9;1639 Medical Center Parkway;Suite 400;Murfreesboro TN 37129
 
ZIP Code
37129
 
Solicitation Number
36C24918Q9550
 
Response Due
8/6/2018
 
Archive Date
11/4/2018
 
Point of Contact
Christina (Tina) Smith
 
E-Mail Address
5-6395<br
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Page 2 of 2 This is a Sources Sought notice for SDVOSB/VOSB. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. Purpose and Objectives: Your responses to the information requested will assist the Government in determining the appropriate acquisition method. NAICS code: 541380 and sized standard is $15M. NOTE: Respondent claiming SDVOSB and VOSB status must be registered and CVE verified in VetBiz Registry www.vetbiz.gov. Project requirements: This requirement is for an annual contract to provide scheduled annual certification of 48 Isolation rooms owned by the VAMC Memphis. Provide semi-annual supply and exhaust readings in 5 (FIVE) rooms Provide annual certification of 34 Fume Hoods Perform semi- annual services to measure the total air flow, room volume, room pressure and the air changes per hour at the VAMC Memphis; Change HEPA filters and pre-filters in building 1A, 1 and 7 once a year and leak test the HEPA's once a year at the VAMC Memphis; and Perform annual certification on 1 biological safety cabinet. Certification of Isolation Rooms: The isolation rooms are used by the VAMC Memphis for patients with air or contact spreadable diseases. The rooms must be maintained in a negative air pressure status when a patient is in the room at minimal.0l with 12 air changes per hour. Contractor/ Vendor shall supply scheduled annual isolation room air flow readings ensuring there are 12 air changes per hour with a minimal of.01 negative air pressures in 48 rooms at VAMC Memphis. The contractor/vendor will invoice once a year. Contractor/ Vendor shall take semi-annual supply and exhaust readings in 5 (five) Nuclear Med rooms. Rooms must measure 6 air changes minimum or meet the current VA standard. Contractor shall perform annual certification on 1 (one) biological safety cabinet in microbiology room. Contractor/ Vendor's service shall consist of all labor, materials, equipment, travel, supervision, and quality control necessary to perform annual isolation room's air flow. Certification of Fume Hoods: These hoods are used by Research to perform test and other experiments. All Hoods must be certified in accordance with manufacturer specifications and ANSI/AIHA 29.5-2003. Contractor/ Vendor shall perform airflow Certification once a year in the month of November. The contractor/vendor will invoice upon completion of the tests. Contractor/ Vendor's service shall consist of all labor, materials, equipment, travel, supervision, and quality control necessary to perform annual air measurements of the fume hoods. The Contractor/ Vendor shall provide 2 (TWO) complete reports for each test to the Maintenance & Operations Supervisor at the VAMC Memphis. The Contractor Vendor must be a certified member of the Associated Air Balance Council (AABC). Anticipated period of performance: 01 October 2018 through 30 September 2019 plus four (4) one-year options. Information sought: Response to this announcement shall not exceed 10 pages and should include the following information: (1) A tailored capability statement indicating the firm s ability to provide a product and related services; (2) The respondents DUNS number, organization name, address, point of contact, and size and type of business (e.g., SDVOSB/VOSB, etc,) pursuant to the applicable NAICS code; (3) Information should be provided electronically in a Microsoft Word or Adobe PDF format. Please e-mail your response with the above information to Christina.Smith7@va.gov with the subject line "Sources Sought Notice # 36C24918Q9550 by Noon on 06 August 2018. Any questions should be emailed to Christina.Smith7@va.gov. Disclaimer and Important Notes. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization s qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality. No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/NaVAMC/VAMCCO80220/36C24918Q9550/listing.html)
 
Document(s)
Attachment
 
File Name: 36C24918Q9550 36C24918Q9550.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4512140&FileName=36C24918Q9550-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4512140&FileName=36C24918Q9550-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: VAMC Memphis;1030 Jefferson Ave.;Memphis, TN
Zip Code: 38104
 
Record
SN05011640-W 20180730/180728230041-e4220b159472af059265bf77c938834e (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.