MODIFICATION
J -- )Communication Tower Inspections - Responses to Questions
- Notice Date
- 7/13/2018
- Notice Type
- Modification/Amendment
- NAICS
- 811213
— Communication Equipment Repair and Maintenance
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, AFLCMC - Hanscom, 9 Eglin Street, Hanscom AFB, Massachusetts, 01731, United States
- ZIP Code
- 01731
- Solicitation Number
- F2B3AQ8149A012
- Archive Date
- 8/9/2018
- Point of Contact
- Brian M. Monahan, Phone: (7812250144, Christian Salinas, Phone: (781) 225-0198
- E-Mail Address
-
brian.monahan.3@us.af.mil, christian.salinas@us.af.mil
(brian.monahan.3@us.af.mil, christian.salinas@us.af.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Responses to Contractor Questions PLEASE NOTE THAT THE GOVERNMENT HAS RECEIVED QUESTIONS FROM CONTRACTORS THAT IT ANSWERS AS FOLLOWS: 1. Do you have any information of the quantity and type of towers that will be inspected? Answer: A: The total amount of towers to be inspected are 7 all located on Hanscom AFB. B: 5 are steel 2 are utility pole/wood type with pole steps all have communication antenna attachments all steal towers are new construction and less than 3 years old. C: Two of the seven are not yet on line being erected currently and will have weather related instruments attached as well as communication antenna. 2. Do you have any past inspections on the existing towers? Answer: No towers have had any structural inspections done to them after the initial construction. 3. Do you want the guyed tower anchors dug to block for an inspection of the whole anchor shafts? When was the last dug to block anchor inspection done? Answer: We would want the tower anchors inspected to verify the structural integrity of the anchor and guy. No inspections have been done since the initial construction. 4. Do you want a structural analysis done on each tower to verify that the current weight can be supported by the existing tower? Answer: We would not require an engineering structural analysis to be done on each tower to verify that the current weight can be supported by the existing tower. If recommended after your inspections and noted within your report we would ask for a cost for the structural analysis to be performed to the tower in question. 5. Any certain time of the year do you want the inspections to be performed? Answer: A spring, summer or fall timeframe for inspections are fine we would ask that the same time within the year be used throughout the length of the contract.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/ESC/F2B3AQ8149A012/listing.html)
- Place of Performance
- Address: Various sites on base., Hanscom AFB, Massachusetts, United States
- Record
- SN04991931-W 20180715/180713231155-1a67320c174f36fecfd435917050e8a9 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |