Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 14, 2018 FBO #6077
DOCUMENT

F -- Cooling Tower Cleaning, Disfenction and Testing of Ligionella Disease. - Attachment

Notice Date
7/12/2018
 
Notice Type
Attachment
 
NAICS
541380 — Testing Laboratories
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 2;James J. Peters VA Medical Center;130 West Kingsbridge Road;Bronx NY 10468-3904
 
ZIP Code
10468-3904
 
Solicitation Number
36C24218Q9499
 
Response Due
7/23/2018
 
Archive Date
8/2/2018
 
Point of Contact
Joel M Paula
 
E-Mail Address
4
 
Small Business Set-Aside
N/A
 
Description
The purpose of this solicitation is to provide cleaning, disinfection, and legionella test after completion to the following cooling towers: Chiller Plant Towers 1&2, 3&4, 5&6, 7&8 EMD Generators Cooling Towers 1&2 All labor, supervision, and required chemistry are included in this scope. The process will include onsite supervision by vendor of all stages of cleaning and refill to ensure the establishment of proper chemical residuals at the end of the process. Contractor to provide before and after electronic documentation, a written report, and a cooling tower cleaning certificate. A legionella test at the end of the process is also to be done to each tower. Tower Cleaning Procedure: The purpose of this section is to present the steps necessary to clean a cooling tower while preventing injuries and accidents and protecting contractor employees from hazards associated with the task. Employees must have proper training regarding tower cleaning practices. PHASE 1 PRE-DISINFECTION Begin the cleaning by adding a biocide to elevate the chlorine level to OSHA standards. Then add a biodispersant to increase the effectiveness of the biocide. Provide protective equipment to workers who perform the disinfection to prevent their exposure to chemicals used for disinfection and aerosolized water possibly containing Legionella bacteria. This procedure calls for a shock treatment with 10PPM free residual chlorine 24 hours previous to the cooling tower mechanical cleaning. PHASE 2 MECHANICAL CLEANING OF THE COOLING TOWER The VA will assist contractor in isolation and draining each cell of the cooling tower. Once the system is locked out, begin the actual cleaning process by using a high pressure power washer to clean the entire tower, internal and external. This phase is done to remove as much of the micro-bio and debris as possible, without the risk of damaging equipment, and have it collect in the tower basin. Provide protective equipment to workers who perform the mechanical cleaning. Inspect all water contact areas for sediment, sludge, and scale. Using brushes and/or low pressure water hose, thoroughly clean all cooling tower water contact areas including basin, sump, fill, spray nozzles, and fittings. Use high pressure water cleaner to thoroughly clean the drift eliminators and fan inlet screens. Remove loose deposits from the sump and cooling tower basin. PHASE 3 FINAL DISINFECTION AND PASSIVATION Fill the system with water, add chlorine to achieve free chlorine level of 10mg/L Circulate water for one hour, open blowdown valve and flush the entire system until the water is free of turbidity. PHASE 4 DOCUMENTATION Supply a CD with time stamped before and after pictures. Supply a written report, detailing all comments and recommendations gathered from the task of cleaning the cooling towers. Supply a certificate that attests that the cooling towers have been professionally cleaned and disinfected in accordance with the OSHA recommendations Take and supply the results of Legionella tests for each tower cell
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BroVANAP/VAMD/36C24218Q9499/listing.html)
 
Document(s)
Attachment
 
File Name: 36C24218Q9499 36C24218Q9499_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4475474&FileName=36C24218Q9499-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4475474&FileName=36C24218Q9499-000.docx

 
File Name: 36C24218Q9499 S02-SOLICITATION.pdf (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4475475&FileName=36C24218Q9499-001.pdf)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4475475&FileName=36C24218Q9499-001.pdf

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04989979-W 20180714/180712231423-880df6b5ef6961ebaaf0efb995da0bd6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.