Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 12, 2018 FBO #6075
DOCUMENT

66 -- CTX Flow cytometer Upgrade - Attachment

Notice Date
7/10/2018
 
Notice Type
Attachment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
00504;Department of Veterans Affairs;Contracting Section;7201 I-40 West Suite 100;Amarillo TX 79106
 
ZIP Code
79106
 
Solicitation Number
36C25718Q9690
 
Response Due
7/17/2018
 
Archive Date
9/15/2018
 
Point of Contact
Lula Hill
 
Small Business Set-Aside
N/A
 
Description
The North Texas VA Health Care System is seeking sources capable of meeting the requirement listed below. The acquisition will be accomplished using commercial item procedures in accordance with FAR Part 13. The North American Industry Classification System (NAICS) are 334516 and 339113. Any firms who wish to identify their interests and capability to provide this service must notify the Contract Specialist no later than NOON PM Central Time, July 17, 2018. Notification shall be e-mailed to Lula Hill, at lula.hill3@va.gov. Provide Cage Code and or DUNS number. DISCLAIMER This Source Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Notice that is marked as proprietary will be handled accordingly. In accordance with the Federal Acquisition Regulation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Notice. SCOPE: Statement of Work for Flow Cytometer Upgrade Vendor will provide an upgrade for the existing Attune NxT Flow Cytometer that includes a Red Laser and AutoSampler that meets the outlined specifications below. Specifications Red Laser: Attune ® NxT Red Laser Upgrade Kit that is designed to expand the 637 nm excitation capabilities of the Attune ® NxT Acoustic Focusing Cytometer. Must enables the detection of APC, Alexa Fluor ® 700, and APC-tandem dyes for immunophenotyping, as well as many other functional reagents such as CellTrace ® Far Red for cell proliferation, LIVE/DEAD ® Fixable Far Red or Near IR dyes for viability, Vybrant ® DyeCycle Ruby dye for live cell cycle analysis, and far red exciting fluorescent proteins. AutoSampler: Key features Compatible with many different plate formats, including 96-well, 384-well, and deep-well plates Intelligent probe design minimizes clogging and carryover (<1%) and helps prevent damage to the instrument Mixes sample by aspiration to enable homogeneity of the sample and to maintain cell viability Performs automated cleaning when the instrument is shut down Helps maintain consistent data while easily switching between use of the autosampler and individual tubes Consistent data across different collection rates Physical characteristics Footprint (H x W x D): approximately 16 x 11 x 11 in. (40 x 29 x 29 cm) Weight: approximately 35 lb (16 kg) Operating temperature: 50 95 °F (15 30 °C) Operating humidity: <80% noncondensing Electrical requirements: 100 240 VAC, 50/60 Hz, <300 W Processing time <45 minutes for 96-well plate using High Throughput mode <60 minutes for 96-well plate using Standard mode, 2 wash cycles <180 minutes for 384-well plate using High Throughput mode <240 minutes for 384-well plate using Standard Software/computer requirements Attune ® NxT Cytometric Software Version 2.0 or higher Windows ® 7 Operating System Compatible plate types 96 deep-well (flat, round, and V-bottom) 96-well standard depth (flat, round, and V-bottom) 384-well standard depth (flat, round, and V-bottom) 384 deep-well (flat, round, and V-bottom) Mixing cycles Each well mixed via full aspiration (not shaking) Wash cycles User-defined number of wash cycles, dependent on plate-processing protocol and time to acquire plates Minimum sample volume required 50 L for 96-well plates Minimum dead volume 30 L Fluidics requirements Onboard fluidics tanks: 800 mL total Capable of running four 96-well plates in Standard mode with two washes per well Carryover <0.5%
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAAHCS/VAAHCS/36C25718Q9690/listing.html)
 
Document(s)
Attachment
 
File Name: 36C25718Q9690 36C25718Q9690_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4470887&FileName=36C25718Q9690-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4470887&FileName=36C25718Q9690-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;Laboratory;4500 S Lancaster Rd;Dallas
Zip Code: TX
 
Record
SN04984656-W 20180712/180710230931-237900c204ddae788a8cec0fe6b62988 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.