Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 11, 2018 FBO #6074
SOLICITATION NOTICE

Z -- RPL of HVAC st Post Office, Bldg 332

Notice Date
7/9/2018
 
Notice Type
Presolicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of the Army, Army Contracting Command, MICC, MICC - Fort Hood, 761st Tank Battalion Ave., Room W103, Fort Hood, Texas, 76544-5025, United States
 
ZIP Code
76544-5025
 
Solicitation Number
W91151-18-B-0010
 
Archive Date
7/31/2018
 
Point of Contact
Mark C. Green, Phone: 2542884103
 
E-Mail Address
mark.c.green.civ@mail.mil
(mark.c.green.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
DESCRIPTION OF WORK: The work shall be located at building 332, located at the intersection of 761ST Tank Battalion Ave and 37TH St, Fort Hood TX. The exact location will be shown by the Contracting Officer. The building will be occupied during the performance of work under this contract. The purpose of this project is to replace the existing HVAC system (AHU, pumps, chiller and all associated accessories) with new HVAC system and upgrade the control system with new DDC control system in bldg. 332. The following drawings are included as part of the Solicitation. G-101 COVER SHEET C-101 SITE PLAN - UTILITIES A-101 FLOOR PLAN MD-101 DEMOLATION MECH. PLAN MD-102 ENLARGED MECH. ROOM - DEMO M-101 NEW MECHANICAL PLAN M-102 ENLARGED MECH. ROOM - NEW M-501 CHILLED WATER PIPING DIAGRAM M-502 HOT WATER PIPING DIAGRAM M-503 MECHANICAL DETAILS M-601 MECHANICAL SCHEDULE M-701 BOILER / CHILLER CONTROLS M-702 AIR HANDLING UNIT CONTROLS M-703 MECHANICAL CONTROLS (LON BUS CONTROLS) One set of solicitation documents, including plans, specifications, and miscellaneous data, will be furnished to the contractor in Adobe PDF format. After award, one set of Adobe PDF contract drawings and PDF specifications, and one set of MicroStation format drawings (if available) will be furnished to the Contractor on CD. Reference publications will not be furnished. Contractor shall immediately check furnished drawings and notify the Government of any discrepancies. A project construction sign will not be required for this project. Contractor shall keep all permits and other documents required to be on the job site in a 3-ring binder or posed on a bulletin board within the construction area. PERFORMANCE PERIOD: Barring any contingencies that arise during construction, the Government requires that this project be completed within 90 calendar days. An additional 30 days will be added to the project completion date to account for processing of award. Completion is defined as completion of all contractual obligations. IDENTIFICATION OF THE PROCUREMENT TEAM: Contracting Officer (ACO): The Contracting Officer has sole authority to obligate the Government. Contracting Officer's Representative (COR): The COR is appointed by the Contracting Officer and serves as the Government's technical representative and primary point of contact in the field following contract award. The COR will inspect various phases of work in progress to ensure the 3-phase inspection plan is in place and being adhered to. The COR will perform all inspection and acceptance on behalf of the Government for this project. Project Manager: The Project Manager developed and reviewed this requirement, and will participate in further developing the project through negotiation of a firm fixed price. The PM will serve as the technical liaison between the Government (fire and safety staff) and the contractor in clarifying work requirements, performance standards, and other technical requirements. Following contract award, the Project Manager is accessible only through coordination with the COR. Design Engineer: Design Engineer developed this requirement, and will participate in further developing and reviewing the project through negotiation of a firm fixed price with the Project Manager. The DE will serve as a technical liaison to the in clarifying work requirements, performance standards, and other technical requirements. Following contract award, the Design Engineer is accessible only through coordination with the COR to the PM.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/f420816051ae2090489a8880402ecad9)
 
Place of Performance
Address: Bldg 332 the post office, on U.S. Army Installation at Fort Hood, Killeen, Texas, 76544, United States
Zip Code: 76544
 
Record
SN04983686-W 20180711/180709231102-f420816051ae2090489a8880402ecad9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.