DOCUMENT
65 -- Lifecare Patient Controlled Analgesia (PCA) Pumps BRAND NAME - Attachment
- Notice Date
- 7/7/2018
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Gulf Coast Veterans Health Care System;Network Contracting Office 16;400 Veterans Avenue;Biloxi MS 39531
- ZIP Code
- 39531
- Solicitation Number
- 36C25618Q9747
- Response Due
- 7/13/2018
- Archive Date
- 8/12/2018
- Point of Contact
- Danette Rene' Impey
- Small Business Set-Aside
- N/A
- Description
- This is a SOURCES SOUGHT NOTICE ONLY. This SOURCE SOUGHT NOTICE is for the purpose of Market Research. Response to this notice will be used for information and planning purposes. No proposals or quotes are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS or QUOTES and NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall NOT be construed as solicitation or as an obligation on the part of the Department of Veterans Affairs (VA). Responses to this notice is not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The Network Contracting Office (NCO) 16 is seeking preferably Service Disabled Veteran Owned Small Businesses, or Small Businesses (but will accept other than small business for market research purposes), capable of providing Patient Controlled Analgesia (PCA) Pumps, brand name only, for Pharmacy Service at the Veterans Health Care System of the Ozarks located at 1100 N. College Avenue, Fayetteville, AR 72703. See DRAFT Statement of Work for detailed description of Supplies. The NAICS code is 339112 Surgical and Medical Instrument Manufacturing and the Size Standard is 1,000 Employees. Responses must be received by no later than 12:00 p.m. Central Time, Friday, July 13, 2018. Responses shall be emailed to rene.impey@va.gov. Responses shall include Capabilities Statements, DUNS number, and whether the requirement is on GSA/FSS schedule or Open Market. Facsimile or Telephonic responses will not be accepted. Note: All interested parties are reminded to be registered, active and verified in the following to be considered for Award. SAM: https://www.sam.gov/portal/public/SAM/ VETBIZ: https://www.vip.vetbiz.gov/Public/Search/Default.aspx Vet 4212 (Veteran owned small Business are reminded of Reporting Requirements) https://www.dol.gov/vets/vets4212.htm DRAFT STATEMENT OF WORK (SOW) Patient Controlled Analgesia (PCA) Pumps 1. Contracting Officer s Representative (COR). Name: James Duncan Section: Pharmacy Service Address: 1100 N. College Ave., Fayetteville, AR 72703 2. Contract Title: Purchase Patient Controlled Analgesia (PCA) Pumps. 3. Background: There is currently a national shortage of controlled substances used for pain medication by the IV route. As part of routine care at the Veterans Health Care System of the Ozarks, we utilize patient controlled analgesia (PCA) pumps to administer pain medication intravenously in two primary areas, Palliative Care Unit, and Intensive Care Unit. To date, we use our primary IV pump system with attachable PCA pump modules for PCA administration. These modules will work with relatively few versions of PCA syringes. With the national shortage of these type pain medications, our sources for sterile re-packaging of these products are no longer able to provide supply to our facility. Pharmaceutical companies continue to manufacture medications for PCA administration in other syringe versions that are compatible with different PCA pumps. 4. Scope. To purchase three (3) PCA pumps that are compatible with the original manufacturer packaged syringe product available to us direct from our Pharmaceutical Prime Vendor (McKesson Wholesale). 5. Specifications/Characteristics: The specific products these pumps are required to accept are manufactured by Hospira Worldwide. Compatible product syringes must include: Morphine 1mg/ml 30ml PCA Syringe by Hospira Worldwide NDC: 000409-2029-02; Morphine 5mg/ml 30ml PCA Syringe by Hospira Worldwide NDC: 000409-6028-04; Meperidine 10mg/ml 30ml PCA Syringe by Hospira Worldwide NDC: 00409-6030-04. Pump specific requirements: Integrated barcode reader for confirming drug concentration; Full electronic health record interoperability; Wireless capability; Remote view infusion information possibility; On-pump programming and confirmation interface; Rechargeable on-board battery with at least 3 hours of continuous operation; Battery recharge to 80% in 16 hours; 105-130 Volt power requirement; Pump will operate on AC power when battery is discharged or charging; System alarms: Empty syringe, door open, infuser paused, low battery, dead battery, bar-code not read, check settings, occlusion, check syringe, check vial, check injector, pendant fault, decimal point not allowed, check PCA infuser set to relieve pressure, malfunction; Lockout interval range 5 to 120 minutes in 1-minute increments; Max infusion pressure 45 psig. Vendor will provide all materials as listed above with delivery to the facility, along with specified training. Dimensions (approximate): 8 Wide X 13 Height X 6 Deep; 10 lbs., including battery. 6. Training: Training included for 1-day of on-site training for end users. 7. Delivery: On or about August 15, 2018. Deliver to: Veterans Health Care System of the Ozarks ATTN: Warehouse 1100 N. College Avenue Fayetteville, AR 72703 8. Contractor Requirement Setup and delivery of specified pumps above with on-site training as indicated.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BiVAMC/VAMCCO80220/36C25618Q9747/listing.html)
- Document(s)
- Attachment
- File Name: 36C25618Q9747 36C25618Q9747.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4464624&FileName=36C25618Q9747-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4464624&FileName=36C25618Q9747-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C25618Q9747 36C25618Q9747.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4464624&FileName=36C25618Q9747-000.docx)
- Place of Performance
- Address: Veterans Health Care System of the Ozarks;ATTN: Warehouse;1100 N. College Avenue;Fayetteville, AR
- Zip Code: 72703
- Zip Code: 72703
- Record
- SN04982425-W 20180709/180707230022-93069cee858e64a137a937cb0e270a65 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |