SOURCES SOUGHT
66 -- Keysight Oscilloscope & Upgrade - Sources Sought NB671000-18-03651
- Notice Date
- 7/3/2018
- Notice Type
- Sources Sought
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B130, Gaithersburg, Maryland, 20899-1410, United States
- ZIP Code
- 20899-1410
- Solicitation Number
- NB671000-18-03651
- Archive Date
- 7/27/2018
- Point of Contact
- Aron Krischel, Phone: 3034973032
- E-Mail Address
-
aron.krischel@nist.gov
(aron.krischel@nist.gov)
- Small Business Set-Aside
- N/A
- Description
- Sources Sought NB671000-18-03651 for Mixed Signal Oscilloscope and Keysight Oscilloscope Upgrade Sources Sought NB67100-18-03651 Mixed Signal Oscilloscope and Upgrade of Keysight Oscilloscope TITLE: Sources Sought for Mixed Signal Oscilloscope and Upgrade of Keysight Oscilloscope The National Institute of Standards and Technology is seeking sources capable of fulfilling the below specifications. If your company has the capabilities, request you email any capability documentation to Aron Krischel, Contracting Officer at aron.krischel@nist.gov. Also, if your company can fulfill this requirement through a GSA schedule, please indicate that in your response. Your responses are due NLT July 12, 2018, 2 PM (Mountain Standard Time). I. BACKGROUND INFORMATION Public Safety Communications Research (PSCR) laboratories provide research, development, testing, and evaluation to foster nationwide public safety communications interoperability. To be able to accurately test, monitor, and measure LMR and LTE signals within National Institute of Standards and Technology (NIST) standards, PSCR requires a mixed-signal oscilloscope. In addition, PSCR requires the activation of upgrade options on its existing government-owned oscilloscope. II. DESCRIPTION The contractor shall provide one (1) mixed-signal oscilloscope, Keysight 6000 X-Series, and additional upgrade options for PSCR-owned oscilloscope, Keysight 3000T X-Series, serial number SG56310019, in accordance with the specifications below. III. SPECIFICATIONS The contractor shall provide the described instruments that conform to the following: A. One (1) Mixed-Signal Oscilloscope 1. Minimum Measurement Specifications (a) Channels: 4 Analog, 16 Digital (b) Memory Depth: 4 Million Points (c) Bandwidth: 1 Gigahertz (GHz) (d) Analog to Digital Converter Bits (ADC): 8 bits (e) Dual Waveform Arbitrary Generator, 20 Megahertz (MHz) 2. Minimum Display Capabilities (a) Internal Display Type: Touchscreen (b) Internal Display Size: 12 Inches 3. Measurement Options (a) Audio Serial Triggering and Analysis – Perpetual License (b) Power Analysis – Perpetual License (c) USB 2.0 Low and High-Speed Measurement – Perpetual License (d) Mask Limit Testing – Perpetual License (e) Inter-Integrated Circuit (I2C) Embedded Serial Triggering – Perpetual License (f) Serial Peripheral Interface (SPI) Bus Triggering – Perpetual License (g) Frequency Response Analyzer – Perpetual License (h) Manchester/Non-Return to Zero (NRZ) Protocol Triggering and Analysis – Perpetual License 4. Vector Signal Analysis (VSA) Software Compatibility (a) Compatible with government’s existing Keysight 89600 VSA Software 5. Warranty (a) Three (3) Year Warranty 6. Initial Calibration (a) Factory Calibration with Uncertainties and Guardbanding (b) Certification of Calibration with results of all required tests/measurement data 7. Calibration Plan (a) Three Year Calibration with Uncertainties and Guardbanding (1) One calibration per year B. Test and Measurement Option Upgrades for Existing Keysight DSOX3034T Oscilloscope, Serial #SG56310019 1. Upgrade to 16 Channel Digital/4 Channel Analog Mixed Signal Analyzer 2. Audio Serial Triggering and Analysis – Perpetual License 3. Power Analysis – Perpetual License 4. Mask Limit Testing – Perpetual License 5. Inter-Integrated Circuit (I2C) Embedded Serial Triggering – Perpetual License 6. Serial Peripheral Interface (SPI) Bus Triggering – Perpetual License 7. Frequency Response Analyzer – Perpetual License 8. Manchester/Non-Return to Zero (NRZ) Protocol Triggering and Analysis – Perpetual License 9. Wavegen Signal Generator – Perpetual License IV. DELIVERY Contractor shall provide all products no later than 120 days after receipt of order (ARO). V. DELIVERABLES KEYSIGHT DESCRIPTION PRODUCT # QTY Mixed Signal Oscilloscope 6000 X-Series MXOX6004A 1 SW Application Bundle for 6000 X-Series DSOX6APPBNDL 1 Return to Keysight Warranty: 3 Years Included w 6000 X 1 Calibration + Uncertainties + Guardbanding: Initial Included w 6000 X 1 Certificate of Calibration plus test data N/A 1 Calibration + Uncertainties + Guardbanding: 3 Years MSOX6000-AMG 1 Rackmount Kit for 6000 X-Series N2111A 1 SW Application Bundle for 3000T X-Series DSOXT3APPBNDL 1 Oscilloscope MSO upgrade for 3000T X-Series DSOXT3MSO 1 VI. ACCEPTANCE / INSPECTION Prior to acceptance and final payment, the product will be functionally tested and verified to ensure conformance with the specifications. VII. WARRANTY Three (3) years on product. VIII. CALIBRATION The contractor shall deliver the product calibrated (see III.A.6. above) and shall update calibration once per year for three (3) years (see III.A.7. above) to commence one (1) year after delivery.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/NB671000-18-03651/listing.html)
- Record
- SN04978670-W 20180705/180703231044-202dfb758cd2b5193b5b2ac771f72da9 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |