SOURCES SOUGHT
J -- Gas Leak Sources Sought
- Notice Date
- 7/2/2018
- Notice Type
- Sources Sought
- NAICS
- 221210
— Natural Gas Distribution
- Contracting Office
- Department of the Air Force, Air Mobility Command, 436th CONS, 639 Atlantic Street, Dover AFB,, Delaware, 19902-5639, United States
- ZIP Code
- 19902-5639
- Solicitation Number
- SouresSoughtGas
- Archive Date
- 7/26/2018
- Point of Contact
- Andrea Hurlburt, Phone: 3026775012
- E-Mail Address
-
andrea.hurlburt@us.af.mil
(andrea.hurlburt@us.af.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- The purpose of this SOURCES SOUGHT is for INFORMATION PURPOSES ONLY to see if companies are able to provide the below services for Dover AFB, DE: Provide natural gas distribution system emergency and routine repairs and maintenance as needed. The contractor shall provide all management, tools, supplies, equipment and labor necessary to repair underground and exterior natural gas piping and related appurtenances to include valves, regulators and meters for Dover AFB in a manner that will ensure the serviceability and safe operation of the natural gas system. All maintenance and repairs to include inspections and testing shall be performed in accordance with AFI 32-1067 and industry standards to include Department of Transportation (DOT) Pipeline and Hazardous Material Safety Administration (PHMSA) (Guidance Manual for Small Natural Gas Systems) as well as Occupational Safety and Health Administration (OSHA) safety guidelines. Excavation safety to include the use of shoring as needed is mandatory. Additionally, prior to any excavation work the contractor will ensure an AF 103 was processed by the Water Fuels Systems Maintenance (WFSM) section to ensure any other underground utilities in the area have been located and marked. The contractor must have a copy of the AF 103 on site while digging. Authorized repairs to pipe leaks ranging from ½ inch to 6-inches in diameter will be made at the direction of the Contracting Officer Representative, Water Fuels Systems Maintenance (WFSM) Foreman or other person of authority within the Civil Engineer Squadron (CES) designated as such. The natural gas system on Dover AFB consists mainly of High Density Polyethylene (HDPE) pipe. Typical repairs to HDPE piping shall be made with electrofusion equipment and fittings designed for such equipment. Upon request an annual line leak survey shall be performed and a report finalized and forwarded to the CES WFSM Foreman for record keeping. Any gas leaks discovered shall be reported in accordance with the DOT PHMSA, Guidance Manual for Small Natural Gas Systems.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AMC/436CONS/SouresSoughtGas/listing.html)
- Place of Performance
- Address: Dover AFB, Dover, Delaware, 19902, United States
- Zip Code: 19902
- Zip Code: 19902
- Record
- SN04977250-W 20180704/180702231113-b4d4cee8601a63d1323438885f7cd185 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |