Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 11, 2018 FBO #6013
MODIFICATION

Z -- Uninterruptible Power Supplies (UPS) PM

Notice Date
5/9/2018
 
Notice Type
Modification/Amendment
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
Social Security Administration Office of Acquisition and Grants 1540 Robert M. Ball Building 6401 Security Blvd Baltimore MD 21235
 
ZIP Code
21235
 
Solicitation Number
28321318Q00000284
 
Response Due
5/22/2018
 
Archive Date
6/6/2018
 
Point of Contact
CROWLEY, TERRY
 
Small Business Set-Aside
Total Small Business
 
Description
This amendment # 0001 to Solicitation # 28321318Q00000284 is necessary to answer Contractor questions and answers. Also to revise SOW with Battery information. 1) Need to know is if these batteries need to be delivered with inside delivery or if dock to dock delivery is acceptable? ANSWER: Dock to dock is acceptable if the shipment is no more than one day before installation. We have very limited storage space on the dock. Contractor employees must move the batteries to the equipment. 2)Provide the make and model number of batteries for each UPS listed in the solicitation: The original SOW listed the wrong quantity for the Eaton 9355. It is corrected on the updated SOW. Here is the battery information: ANSWER: Eaton 9355, 20kVA, Model # KB2013100000010, Serial #BF034KXX10, Manufactured Feb. 2012 3 strings of 18 batteries, battery model Eaton PWHR1234W2FR 8 strings of 18 batteries, battery model Eaton PWHR12120W3FR APC MGE Galaxy 4000, 40kVA, Model #72-173005-00, Serial # PP14-000063, Manufactured Oct. 2014 3 strings of 20 batteries, battery model C&D Technologies UPS12-490MR Eaton Power Xpert 9395, 300kVA, Model #9395-275, Serial #EJ513BAA05, Manufactured Aug. 2016 1 string of 40 batteries, battery model Data Safe 12XE1010F-FR Eaton Power Xpert 9395, 300kVA, Model #9395-275, Serial #EJ513BAA06, Manufactured Aug. 2016 1 string of 40 batteries, battery model Data Safe 12XE1010F-FR 3)In regard to frequency of maintenance for UPS & Batteries, industry standard is quarterly battery and semi-annual UPS PM service. In the solicitation, it states for contractor to submit with quote the scope & frequencies of PM service. Can the SSA standardize the frequency to all potential suppliers in order to receive fair price comparison? Without a standard maintenance frequency required, you may receive a lower tiered level of support for your critical operations. ANSWER: See the SOW Section 2.2. The standard is for high reliability applications as specified in ANSI/NETA Standard for Maintenance Testing Specifications for Electrical Power Equipment and Systems. 4) What is the brand of the existing UPS equipment? ANSWER: See the Statement of Work Section B-1 Description of the solicitation. 5) Identify the currently installed batteries by size (volt/amp) or model number? ANSWER: See question #1 above. 6) Do you have a loading dock? ANSWER: Yes. 7) Can the battery replacements be performed during normal business hours? ANSWER: Yes, if it can be done without interrupting power to the load. 8) Are all of the units at the same location? ANSWER: Yes, at 1221 Nevin Avenue, Richmond, CA. 9) Can you confirm the below equipment list is accurate and complete? And can we have the KVA sizes? ANSWER: See Section B-1 Description of the Statement of Work. 10) Can you please advise on the quantity and model # for the batteries associated with each UPS? ANSWER: See Section B-1 Description of the Statement of Work. 11) Can you advise if there are any wet cell batteries included in this equipment listing? ANSWER: There are no wet cell batteries in this equipment. 12) Are you looking for semi-annual maintenance on all batteries? ANSWER: See the Statement of Work, 2.2 PREVENTIVE MAINTENANCE 13) Certifications are usually only for Manufacturer Technicians ? ANSWER: For the purposes of Section 1.3 REGULATORY COMPLIANCE, certified to perform the work means having met the requirements of Federal, State and local authorities and any requirements established by the ANSI standard. 14) Currently APC Schneider has declared the Galaxy UPS you have to be end of life . This means APC Schneider will no longer manufacturer replacement parts, usually 2-3 years later these models will need to be totally replaced. Is this true? ANSWER: We are not aware of this. SEE ATTACHED REVISED SOLICITATION TEXT - SECTION B - 1 DESCRIPTION FOR REVISED BATTERY INFORMATION. THIS SOLICITATION IS EXTENDED THROUGH TUESDAY, MAY 22, 2018, 5:00PM CST.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/SSA/DCFIAM/OAG/28321318Q00000284/listing.html)
 
Record
SN04917388-W 20180511/180509231115-aa1f92b84936dd96b17f2f8c78a27b01 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.