Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 02, 2018 FBO #6004
DOCUMENT

61 -- Uninterruptable Power Sources APC Battery and Rack Mount System 506-18-2-392-0018 - Attachment

Notice Date
4/30/2018
 
Notice Type
Attachment
 
NAICS
335911 — Storage Battery Manufacturing
 
Contracting Office
Department of Veterans Affairs;Ann Arbor Healthcare System;Network Contracting Office 10;2215 Fuller Road;Ann Arbor MI 48105
 
ZIP Code
48105
 
Solicitation Number
36C25018Q0657
 
Response Due
5/3/2018
 
Archive Date
5/18/2018
 
Point of Contact
Terry Van Allen
 
E-Mail Address
2-6173<br
 
Small Business Set-Aside
Veteran-Owned Small Business
 
Description
eBuy/GSA Request for Quote This is a combined synopsis/solicitation for APC (Brand Name Only) commercial items under NAICS 335911 (or similar coding), prepared in accordance with FAR Subpart 12.6, as supplemented with additional information included in this notice for the Veterans Administration Ann Arbor, MI 48105. Responses should include the following information: (1) Business Name and Address, (2) Point of Contact Name and Phone Number and E-mail Address, (3) GSA/FSS Contract Number, (4) DUNS and NAICS codes, (5) Business type--SERVICE DISABLED VETERAN OWNED or VETERAN OWNED SMALL BUSINESS. Please note that the requirement is a waived NAICS code under the non-manufacturer rule, so this solicitation is a set-aside for Service Disabled Veteran Owned Small Business and Veteran Owned Small Business under FAR 19.102, and VAAR 852.219-10 and 852.219-11. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-83. All responsible sources may submit a proposal which shall be considered by the contracting officer. Please include warranty information with your offer. Delivery is needed 30 days ARO. FOB Destination. Items will be shipped to: VA Medical Center, 2215 Fuller Road, Ann Arbor, Michigan 48105-2330. Quotes shall be submitted to Terry Van Allen, Contracting Specialist, at terry.vanallen@va.gov no-later- than Thursday, May 3, 2018 at 11:59 pm, Eastern Time. For information regarding this solicitation please contact Terry Van Allen at terry.vanallen@va.gov. To be technically acceptable, items must be TAA Compliant. Please see the general requirement below and the detailed requirements on the following pages: ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT PRICE AMOUNT 0001 0002 APC: Uninterruptable Power Sources (UPS) Compatible Rack Mount Systems 10 15 DETAILED DESCRIPTIONS AND SPECIFICATIONS: Procurement of 10 each Uninterruptable Power Sources (UPS) with 15 compatible rack mount system to replace failing equipment. These UPS systems must be a direct replacement of current failing system without modification to either system. Items are integrated into the VA system at the Ann Arbor location. The required APC Brand (make & model) meets this requirement and need, below. Item Description Prod # APC Smart-UPS SRT 5000VA 208V IEC UPS SRT5KXLT-IEC Rack PDU, Basic, 1U, 16A, 208/230V, (12) C13 Rack power distribution AP9565 UPS: Minimal Output Specifications Output power capacity: 4.25 KWatts / 5.0 kVA Max Configurable Power (Watts): 4.25 KWatts / 5.0 kVA Nominal Output Voltage: 208V Output Voltage Distortion: Less than 2% Output Frequency (sync to mains): 50/60Hz +/- 3 Hz Other Output Voltages: 240 Load Crest Factor: 3: 1 Topology: Double Conversion Online Waveform type: Sine wave Output Connections: (2) IEC Jumpers (Battery Backup) (4) IEC 320 C19 (Battery Backup) (4) IEC 320 C13 (Battery Backup) Bypass: Internal Bypass (Automatic and Manual) Minimal Input Specifications Nominal Input Voltage: 208V Input frequency: 40 - 70 Hz (auto sensing) Input Connections: NEMA L6-30P Cord Length: 10ft ( 3.05meters ) Input voltage range for main operations: 160 - 275V Input voltage adjustable range for mains operation: 100 - 275 (half load)V Number of Power Cords: 1 Other Input Voltages: 240 Minimum Battery Specifications Battery type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leak proof recharge time: 1.5hour(s) Battery Volt-Amp-Hour Capacity: 840 Minimum Communication & Management Specifications Interface Port(s): RJ-45 10/100 Base-T, RJ-45 Serial, Smart-Slot, USB Control panel: Multi-function LCD status and control console Audible Alarm: Audible and visible alarms prioritized by severity Emergency Power Off (EPO): Yes Maximum Physical Specifications Maximum Height 17.0inches ( 432mm, 43.2cm ) Maximum Width 5.1inches ( 130mm, 13.0cm ) Maximum Depth 28.32inches ( 719mm, 71.9cm ) Rack Mount System: Overall Requirement: Compatible with procured UPS Maximum Physical Specifications Maximum Height: 1.75inches ( 44mm, 4.4cm ) Maximum Width: 20.75inches ( 527mm, 52.7cm ) Maximum Depth: 3.5inches ( 89mm, 8.9cm )
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAAAHCS506/VAAAHCS506/36C25018Q0657/listing.html)
 
Document(s)
Attachment
 
File Name: 36C25018Q0657 36C25018Q0657.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4266845&FileName=36C25018Q0657-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4266845&FileName=36C25018Q0657-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;VA Ann Arbor Healthcare System;2215 Fuller Road;Ann Arbor, Michigan
Zip Code: 48105
 
Record
SN04905158-W 20180502/180430230822-21a179a930e6a1bced2dc89778f00f54 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.