DOCUMENT
61 -- Uninterruptable Power Sources APC Battery and Rack Mount System 506-18-2-392-0018 - Attachment
- Notice Date
- 4/30/2018
- Notice Type
- Attachment
- NAICS
- 335911
— Storage Battery Manufacturing
- Contracting Office
- Department of Veterans Affairs;Ann Arbor Healthcare System;Network Contracting Office 10;2215 Fuller Road;Ann Arbor MI 48105
- ZIP Code
- 48105
- Solicitation Number
- 36C25018Q0657
- Response Due
- 5/3/2018
- Archive Date
- 5/18/2018
- Point of Contact
- Terry Van Allen
- E-Mail Address
-
2-6173<br
- Small Business Set-Aside
- Veteran-Owned Small Business
- Description
- eBuy/GSA Request for Quote This is a combined synopsis/solicitation for APC (Brand Name Only) commercial items under NAICS 335911 (or similar coding), prepared in accordance with FAR Subpart 12.6, as supplemented with additional information included in this notice for the Veterans Administration Ann Arbor, MI 48105. Responses should include the following information: (1) Business Name and Address, (2) Point of Contact Name and Phone Number and E-mail Address, (3) GSA/FSS Contract Number, (4) DUNS and NAICS codes, (5) Business type--SERVICE DISABLED VETERAN OWNED or VETERAN OWNED SMALL BUSINESS. Please note that the requirement is a waived NAICS code under the non-manufacturer rule, so this solicitation is a set-aside for Service Disabled Veteran Owned Small Business and Veteran Owned Small Business under FAR 19.102, and VAAR 852.219-10 and 852.219-11. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-83. All responsible sources may submit a proposal which shall be considered by the contracting officer. Please include warranty information with your offer. Delivery is needed 30 days ARO. FOB Destination. Items will be shipped to: VA Medical Center, 2215 Fuller Road, Ann Arbor, Michigan 48105-2330. Quotes shall be submitted to Terry Van Allen, Contracting Specialist, at terry.vanallen@va.gov no-later- than Thursday, May 3, 2018 at 11:59 pm, Eastern Time. For information regarding this solicitation please contact Terry Van Allen at terry.vanallen@va.gov. To be technically acceptable, items must be TAA Compliant. Please see the general requirement below and the detailed requirements on the following pages: ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT PRICE AMOUNT 0001 0002 APC: Uninterruptable Power Sources (UPS) Compatible Rack Mount Systems 10 15 DETAILED DESCRIPTIONS AND SPECIFICATIONS: Procurement of 10 each Uninterruptable Power Sources (UPS) with 15 compatible rack mount system to replace failing equipment. These UPS systems must be a direct replacement of current failing system without modification to either system. Items are integrated into the VA system at the Ann Arbor location. The required APC Brand (make & model) meets this requirement and need, below. Item Description Prod # APC Smart-UPS SRT 5000VA 208V IEC UPS SRT5KXLT-IEC Rack PDU, Basic, 1U, 16A, 208/230V, (12) C13 Rack power distribution AP9565 UPS: Minimal Output Specifications Output power capacity: 4.25 KWatts / 5.0 kVA Max Configurable Power (Watts): 4.25 KWatts / 5.0 kVA Nominal Output Voltage: 208V Output Voltage Distortion: Less than 2% Output Frequency (sync to mains): 50/60Hz +/- 3 Hz Other Output Voltages: 240 Load Crest Factor: 3: 1 Topology: Double Conversion Online Waveform type: Sine wave Output Connections: (2) IEC Jumpers (Battery Backup) (4) IEC 320 C19 (Battery Backup) (4) IEC 320 C13 (Battery Backup) Bypass: Internal Bypass (Automatic and Manual) Minimal Input Specifications Nominal Input Voltage: 208V Input frequency: 40 - 70 Hz (auto sensing) Input Connections: NEMA L6-30P Cord Length: 10ft ( 3.05meters ) Input voltage range for main operations: 160 - 275V Input voltage adjustable range for mains operation: 100 - 275 (half load)V Number of Power Cords: 1 Other Input Voltages: 240 Minimum Battery Specifications Battery type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leak proof recharge time: 1.5hour(s) Battery Volt-Amp-Hour Capacity: 840 Minimum Communication & Management Specifications Interface Port(s): RJ-45 10/100 Base-T, RJ-45 Serial, Smart-Slot, USB Control panel: Multi-function LCD status and control console Audible Alarm: Audible and visible alarms prioritized by severity Emergency Power Off (EPO): Yes Maximum Physical Specifications Maximum Height 17.0inches ( 432mm, 43.2cm ) Maximum Width 5.1inches ( 130mm, 13.0cm ) Maximum Depth 28.32inches ( 719mm, 71.9cm ) Rack Mount System: Overall Requirement: Compatible with procured UPS Maximum Physical Specifications Maximum Height: 1.75inches ( 44mm, 4.4cm ) Maximum Width: 20.75inches ( 527mm, 52.7cm ) Maximum Depth: 3.5inches ( 89mm, 8.9cm )
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAAAHCS506/VAAAHCS506/36C25018Q0657/listing.html)
- Document(s)
- Attachment
- File Name: 36C25018Q0657 36C25018Q0657.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4266845&FileName=36C25018Q0657-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4266845&FileName=36C25018Q0657-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C25018Q0657 36C25018Q0657.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4266845&FileName=36C25018Q0657-000.docx)
- Place of Performance
- Address: Department of Veterans Affairs;VA Ann Arbor Healthcare System;2215 Fuller Road;Ann Arbor, Michigan
- Zip Code: 48105
- Zip Code: 48105
- Record
- SN04905158-W 20180502/180430230822-21a179a930e6a1bced2dc89778f00f54 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |