MODIFICATION
Z -- REPAIR BLDG. 6131 - Amendment 2
- Notice Date
- 4/10/2018
- Notice Type
- Modification/Amendment
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of the Army, National Guard Bureau, 127 MSG/MSC, MI ANG, 43200 MAPLE STREET, BLDG 105, SELFRIDGE ANG BASE, Michigan, 48045-5213, United States
- ZIP Code
- 48045-5213
- Solicitation Number
- W912JB-18-R-9002
- Point of Contact
- Steven Stocking, Phone: 5862394881, Timothy Frasier,
- E-Mail Address
-
steven.a.stocking3.mil@mail.mil, timothy.d.frasier.mil@mail.mil
(steven.a.stocking3.mil@mail.mil, timothy.d.frasier.mil@mail.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Amendment to solicitation to include RFI deadline change and SOW changes. The required performance has changed from REPAIR BLDG. 6131PROJECT NO. CYTL182383 The Contractor shall perform the following 1. Replace weather stripping on all doors. 2. Install and seal "L" shaped flashing in existing 8'-5" x 7'-4" double door in East elevation tower. 3. Remove all existing window caulking and replace it with new caulking and backer rods. 4. Seal all cracks and pipes openings in CMU walls. 5. Caulk all failed control joints in CMU. 6. Caulk bottom side of window sill flashing overhang. 7.Seal all structural steel penetrations through masonry at cab (observation tower). 8. Replace all masonry weeps with PVC style." 09 Replace exterior thresholds embedded in silicone sealant. 10. Remove wall paper Rm. 305. Remove mold damaged drywall and replace drywall and paint all the walls within. 11. Installvinyl siding (vinyl shingles) with insulation over cement board siding panels in south façade of the building. Dimensions: 35.5' x 11'. Total area 391 SF. 12. Dam proof south east elevation below grade where rooms are below grade. The projects magnitude is between $25,000,000 and $100,000,000; to REPAIR BLDG. 6131PROJECT NO. CYTL182383 The Contractor shall perform the following 1. Provide lump sum for all works included. 2. Replace weather stripping on all doors. (10 Doors) 3. Remove all existing window caulking and replace it with new caulking and backer rods. Approx. 500 LF 4. Seal all cracks and pipes openings in CMU walls. Approx. 200 LF 5. Caulk all failed control joints in CMU. 6. Caulk bottom side of window sill flashing overhang. (see building drawings) 7. Seal all structural steel penetrations through masonry at cab (observation tower). 8. Replace all masonry weeps with PVC style. (approx. 100 Each) 9. Replace exterior thresholds embedded in silicone sealant. (approx. 10 each)10. Remove wall paper Rm. 305. Remove and dispose mold damaged drywall and replace drywall and paint all the walls within. Approximate area 200 SF. 11. Install carpet tile and base 350 SF total area.12. Install gauge 24 hot deep galvanized metal siding with insulation over double metal door in east façade of the building. Dimensions: 8'-5" x 7'-4". The projects magnitude is between $25,000,000 and $100,000,000;.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA20-2/W912JB-18-R-9002/listing.html)
- Place of Performance
- Address: Gamp Grayling ANGB, MI, United States
- Record
- SN04884792-W 20180412/180410231034-10ed9b375c8a633c7a2e183508318fa3 (fbodaily.com)