MODIFICATION
Z -- Repair South Switching Station - Solicitation 1
- Notice Date
- 4/10/2018
- Notice Type
- Modification/Amendment
- NAICS
- 237130
— Power and Communication Line and Related Structures Construction
- Contracting Office
- Department of the Air Force, Air Education and Training Command, 502d Contracting Squadron, 1655 Selfridge Avenue, JBSA Lackland, Texas, 78236-5253, United States
- ZIP Code
- 78236-5253
- Solicitation Number
- FA301618R0028
- Response Due
- 5/10/2018 2:00:00 PM
- Archive Date
- 5/25/2018
- Point of Contact
- Paul J Kraus, Phone: 2106528599, Jon L. Sanders, Phone: 2106529103
- E-Mail Address
-
paul.kraus.1@us.af.mil, jon.sanders.2@us.af.mil
(paul.kraus.1@us.af.mil, jon.sanders.2@us.af.mil)
- Small Business Set-Aside
- Woman Owned Small Business
- Description
- Atch 12, Detailed Cost Estimate Breakdown Example Atch 11, Contractor Responsibility Questionnaire Atch 10, Financial Information Questionnaire Atch 9, DD Form 1354 Atch 8, Project Location Atch 7, Local Information Atch 6, Progress Schedule Atch 5, HAZMAT Letter Atch 4, AETC Form 47 Atch 3, Base Access Request Atch 2, Wage Determination Atch 1, Statement of Work Request for Proposal REQUEST FOR PROPOSAL This acquisition will be set aside 100% for a woman owned small business. The North American Industry Classification Code (NAICS) for this requirement is 237130 with a size standard of $36.5M. In accordance with FAR Part 4.1102 and DFARS 252.204-7004, Alternate A, System for Award Management (SAM), contractor must be registered in SAM prior to award. Offerors may obtain information on registration at https://www.sam.gov. The objective of this project is to Repair South Switching Station; Project Number TYMX111031, JBSA-Randolph, TX. General Scope of Work: Repair South Switching Station, Bldg 847 JBSA - Randolph, TX. Design and construct new building to replace an outdated south switching station, B847. The South Switching Station is one of the primary means to distribute electrical service to the South side of JBSA-Randolph. The switching station is in need of replacement due to the age of the equipment, cable condition, and the increase of the electrical loads. Contractor shall construct the new South Switching Station building and electrical equipment to replace the existing South Switching Station in accordance with all applicable criteria. Contractor shall develop a typical switching station floor plans (Architectural, Electrical, Mechanical, Fire Protection, Civil Site Plan, Communication Technology plans, etc.). The Contractor shall construct a new masonry building (approx. 60-ft long x 30-ft wide) with a basement and a ground floor to house the new medium voltage switchgear, in accordance with all applicable criteria. The basement level floor shall be constructed to accommodate all extended feeder conductors for all medium voltage feeders. The new building shall have at least the following rooms in the ground floor: electrical equipment room, electrical room. Communication room, basement access room, and a storage room. The new building shall match the architectural looks of the other buildings in the area (Spanish Colonial Revival architecture), to include exterior lighting, clay tile roof, and historic façade. Provide an overhead roll-up door with enough space to fit the new 15KV switchgear equipment through it and access to the exterior with a paved driveway (similar to loading dock) to allow a vehicle to drive up to the new door. The new building shall be constructed within the same area or vicinity of the existing switching station. The Contractor shall provide the following features in the new building: HVAC system, interior and exterior lighting, emergency lighting, electrical power, fire alarm, Lightning Arrestor system, remote fire sprinkler system and connection, sump pump, Uninterruptible Power Supply (UPS), Manual Transfer System (MTS), generator connections, EMCS system compatibilities and connection, communication, driveways and include all items for a complete and usable system. The Contractor shall submit 35%, 65%, 95%, 100%, and Final design packages for Government comment/approval. The 502D Contracting Squadron, JBSA-Randolph, TX intends to award a contract with a 375 calendar day period of performance. The estimated magnitude of the entire contract is between $1,000,000 and $5,000,000. Note: The above description of work is for the purpose of general information only and is not intended to include and describe every feature or item of work or to define the scope of work. Offerors are responsible for routinely checking the FBO website for any possible solicitation amendments that may be issued. This notice does not commit the Government to award a contract. No collect calls or facsimile transmissions will be accepted. Any costs incurred as a result of a response to this announcement shall be borne by the firm and will not be charged to the Government for reimbursement.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AETC/LackAFBCS/FA301618R0028/listing.html)
- Place of Performance
- Address: Joint Base San Antonio-Randolph, Bldg 847, JBSA-Randolph, Texas, 78150, United States
- Zip Code: 78150
- Zip Code: 78150
- Record
- SN04884718-W 20180412/180410231017-20a9b468bc95835f6bdb59495ed190f8 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |