Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 12, 2018 FBO #5984
SOLICITATION NOTICE

99 -- Anderson Greenwood Model# 9390P02SSTA Pressure Relief Valve or its equivalent - Package #1

Notice Date
4/10/2018
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334419 — Other Electronic Component Manufacturing
 
Contracting Office
Department of Energy, Brookhaven National Laboratory (DOE Contractor), Brookhaven, PO Box 5000, Bldg. No. 355, Upton, New York, 11973
 
ZIP Code
11973
 
Solicitation Number
BG314291
 
Archive Date
4/13/2018
 
Point of Contact
Beth Gilman, Phone: 6313444144
 
E-Mail Address
gilman@bnl.gov
(gilman@bnl.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
Form 9 Commercial Terms Work on Site Terms REQUEST FOR QUOTATION FOR THE FOLLOWING ITEMS OR ITS EQUIVALENT: 4EA Anderson Greenwood Model# 9390P02SSTA Pressure Relief Valve w/ BFP and Field Test Connection: REQUIREMENTS: 1. Set Pressure to relieve - 0.400 Barg ( 5.745 psig ) across PRV with the tolerance +/- 3% or less, that corresponds to +/- 0.012 Bar ( +/- 0.173 psi ) or less of Set Pressure. An ability to adjust the Set Pressure down to 0.3 Barg keeping the same tolerances would be a plus. 2. Allowable Overpressure is 10% maximum above Set Pressure. That corresponds to 0.436 Barg ( 6.33 psig ) maximum allowable inlet pressure across PRV during the pressure relieving. 3. Reseat Pressure - 92... 95 % of Set Pressure. That corresponds to 0.365... 0.377 Barg ( 5.467... 5.294 psig ) across PRV. 4. PRV opening shall be SNAP ACTING mode. 5. The required Helium gas flow capacity - 342 kg/h ( 754 lb/h ) or more. Pressure Relief Valve calculation report is required. The applicable standard for the calculation shall be either API Standard 520, Part I - Sizing and Selection or ASME BPVC Section VIII, Division I, UG-125 to UG-137 - Pressure Relief Devices. 6. Ability to operate at the cryogenic temperatures down until 78 K ( -320 °F) is required. 7. Back Flow Preventer (BFP) is required for this pilot operated valve because the pressure in the Cavity cryostat may drop below the atmospheric pressure (vacuum region). 8. Field Test Connection for the field service and testing is required. 9. The O2 special cleaning is not required, the general cleaning in accordance to the manufacturer procedure is acceptable. 4EA Field service Equivalent Guidelines: The parts or model numbers are listed for reference purposes only. Any alternate products being offered shall have equivalent, or greater, performance parameters to those specified. Suppliers that are offering alternate products shall list the manufacturer, model, and part numbers for the product. When quoting an alternate product, please provide sufficient documentation to permit thorough evaluation of the equivalency of your offer to the product specified AMS-Form-009 - Representations and Certifications - Procurement Specific. Due to the value of this contract, DOE requires Business Representations and Certifications be completed for all procurements exceeding $10,000. PDF version attached: Please complete the attached form, referencing Purchase Order # 314291 on the form and all correspondence. You must complete the form as to avoid unnecessary completion of questions. Please return all nine (9) pages of the document. Insurance: Upon award, in accordance with Article 6 of the attached "BSA Supplemental Terms and Conditions for Work by Contractors On Site at Brookhaven National Laboratory", the contractor is required to furnish a Certificate of Insurance naming "Brookhaven Science Associates, LLC and the U.S. Government" as additional insureds. Prior to coming on site to perform work, the certificate must remain in effect for the duration of the subject contract and must be filed with BNL Procurement & Property Management Division Any resulting purchase order will be subject to the attached terms and conditions
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/BHL/BNL/BG314291/listing.html)
 
Place of Performance
Address: 902B Cornell Ave, Upton, New York, 11973, United States
Zip Code: 11973
 
Record
SN04884593-W 20180412/180410230949-15050c7bf765eee96d3c4479e78344ea (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |