Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 07, 2018 FBO #5979
DOCUMENT

J -- VA263-18-AP-3632 - Oxidant Monitoring - Fargo - Attachment

Notice Date
4/5/2018
 
Notice Type
Attachment
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
Department of Veterans Affairs;Network 23 Contracting Office (NCO 23);113 Comanche Rd.;Fort Meade SD 57741
 
ZIP Code
57741
 
Solicitation Number
36C26318Q0499
 
Response Due
4/10/2018
 
Archive Date
5/10/2018
 
Point of Contact
Stephen Holly
 
E-Mail Address
Stephen.Holly@va.gov
(stephen.holly@va.gov)
 
Small Business Set-Aside
N/A
 
Description
This announcement constitutes a Sources Sought Notice. This is not a Request for Quote (RFQ) or a Request for Proposal (RFP). This announcement is for information and planning purposes only and is not to be construed as a commitment by the government, implied or otherwise, to issue a solicitation or award a contract. Fargo VA Medical Center, 2101 Elm Street, Fargo, ND has a requirement for a Firm Fixed Price Service Contract to be performed at the VA Medical Center campus, Fargo, ND. The purpose of this notice is to determine interest and capability of potentially qualified businesses in particular Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and Veteran-Owned Small-Businesses (VOSB) relative to the North American Industry Classification code (NAICS) 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. To make an appropriate acquisition decision for this requirement, the Government will use responses to this sources sought synopsis. The type of solicitation issued and the manner of advertisement will also depend on the response to this sources sought synopsis. General Information The Fargo VA Medical Center (MVAMC) is currently seeking a company that can provide a maintenance program for operation of Chloramine Monitoring and/or Chlorine Dioxide Dosing Systems (Oxidant Panels) that are currently installed at the Fargo VA Health Care facility. Introduction and Scope of Work The purpose of this equipment service is to assist in meeting the current IC-25 VA Legionella Directive for mitigation of legionella in potable water. Description of Service This document covers the materials and service necessary, for a period of one year, to operate seven (7) Chloramine Monitoring and/or Chlorine Dioxide Dosing Systems (Oxidant Panels) that are currently installed at the Fargo VA Health Care facility. Servicer Servicer shall have the following qualifications. The Servicer is the actual Servicer of the equipment being serviced: Grundfos sourced components. The Servicer has successfully serviced similar equipment for at least 5 years. The Servicer has the required financial capability. The Servicer maintains a qualified technical engineering staff. The Servicer operates a physical plant and shall maintain competent service personnel to service the systems referenced here. Maintenance of Chloramine Monitoring Systems Servicer shall provide and maintain Membranes and Electrolyte Solutions in Chloramine Monitoring and Chlorine Dioxide Sensors. Servicer shall perform calibration of sensors. Servicer shall evaluate and program each system for proper operation. Maintenance of Chlorine Dioxide Feed Systems Servicer shall provide and maintain a five gallon container of Chlorine Dioxide; as described in part 3.00 paragraph B; within the secondary containment vessels located at each of the four feed locations. The Chlorine Dioxide shall be NSF/ANSI 60 approved and GSA Listed diluted solution (0.3%). See attached IC-25 VA Legionella Directive. Safety interlocks: The Servicer shall train the customer on controlled safety interlock to shut-down the entire system. The Servicer shall verify programming of equipment to cease Chlorine Dioxide feed if the level sensors exceed.8ppm as CLO2 in treated water. See attached IC-25 VA Legionella Directive. Chlorite: The Servicer shall train customer on Chlorite testing procedures. Start Up of Equipment for Chlorine Dioxide Feed Cycles Starting of feed systems for each Chlorine Dioxide Feed Cycle will be performed by Servicer. Specific Mandatory Task and Associated Deliverables Servicer shall perform up to eighteen (18) site visits to include monthly maintenance of the Oxidant Panels and start up of four Chlorine Dioxide feed cycles as defined in the Statement of Work(SOW). Submission requirements for responses to this sources sought notice: Interested vendors need to provide a letter of interest along with their capabilities statement. Where to send responses: ATTN: Stephen Holly Stephen.holly@va.gov Response Deadline: 10 April 2018, 1400 MST
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VABHHCS568/VABHHCS568/36C26318Q0499/listing.html)
 
Document(s)
Attachment
 
File Name: 36C26318Q0499 36C26318Q0499 Sources Sought.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4207194&FileName=36C26318Q0499-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4207194&FileName=36C26318Q0499-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veteran Affairs;VAMC Fargo, ND;2101 Elm Street;Fargo, ND
Zip Code: 58102-2417
 
Record
SN04879194-W 20180407/180405230947-01efcbd1fc2c775fbf63bf26aab506d8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.