Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 28, 2018 FBO #5969
DOCUMENT

23 -- MORGUE TRAILER - Attachment

Notice Date
3/26/2018
 
Notice Type
Attachment
 
NAICS
336214 — Travel Trailer and Camper Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 6;100 Emancipation Drive;Hampton VA 23667
 
ZIP Code
23667
 
Solicitation Number
36C24618Q0547
 
Response Due
3/30/2018
 
Archive Date
4/29/2018
 
Point of Contact
Jamie Sullivan
 
Small Business Set-Aside
Total Small Business
 
Description
The purpose of this amendment is to remove part numbers listed by some of the salient characteristics. The salient characteristics below reflect the change. Salient Characteristics Refrigerated morgue trailer must be white in color. Refrigerated morgue trailer must be capable of holding a minimum of 12 total remains. Refrigerated morgue trailer must come with 3 each 4 tier cadaver racks. Racks must be a minimum of 80.6 inches long 26.6 inches wide and 73 inches tall. Refrigerated morgue trailer must come with 12 Stainless steel Cadaver storage trays. 78 inches long 23 inches wide and 4 inches deep. Refrigerated morgue trailer Must be a minimum of 14 Feet long X 8-foot-wide X 7 foot 6 inches high and a maximum of 14 Feet long X 8-foot-wide X 8 foot (interior height) Refrigerated morgue trailer must include a minimum of a 48-inch-wide rear ramp door with ramp extension and gap cover. Refrigerated morgue trailer must have non-skid, one-piece marine grade rubber flooring. Refrigerated morgue trailer must have commercial grade composite sidewall and ceiling with 4 inches of closed cell spray foam insulation. Refrigerated morgue trailer must have tubular steel frame with vertical wall posts that are 16 inches on center for walls. Refrigerated morgue trailer must have one-piece flat top roof and be able to walk on. Refrigerated morgue trailer must be a minimum of.030 exterior skin. Refrigerated morgue trailer must maintain a minimum operating temperature of between 38-42 degrees Fahrenheit. Refrigerated morgue trailer must have an over the road commercial duel temperature refrigeration system. Running on 110 volts 30 AMP System. Refrigerated morgue trailer must have Vinyl Strip Curtains. Refrigerated morgue trailer must have an electric start Generac genset generator capable of running entire trailer. Rated 8000 watts Maximum output of 10000 watts. Refrigerated morgue trailer must have an aluminum vented generator cover. Refrigerated morgue trailer must have a maximum gross weight of 10,400 Pounds. Morgue trailer must include a minimum of a 3-year warranty on trailer and a minimum 1-year warranty on refrigeration and electrical. Refrigerated morgue trailer must have an undercoated main frame. Refrigerated morgue trailer must have DOT certified LED exterior lighting. Refrigerated morgue trailer must Duel electronic breaks with battery breakaway system. Refrigerated morgue trailer must have tandem Torflex EZ lube axles. Refrigerated morgue trailer must have standard spare tire. Refrigerated morgue trailer must have Speed clip rack / load securing system installed. Refrigerated morgue trailer must have a single point electrical distribution panel with intergraded 110-volt breakers 12-volt fuses and a 12-volt battery with 12-volt converter. Refrigerated morgue trailer must include 12-volt interior lighting and exterior loading lights.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HaVAMC/VAMCCO80220/36C24618Q0547/listing.html)
 
Document(s)
Attachment
 
File Name: 36C24618Q0547 36C24618Q0547_3.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4177951&FileName=36C24618Q0547-002.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4177951&FileName=36C24618Q0547-002.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Salisbury VAMC;1601 Brenner Ave;Salisbury
Zip Code: NC
 
Record
SN04867082-W 20180328/180326231421-1cff39341db880f0fa09ff739f7d63c4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.