DOCUMENT
J -- EtO Sterilizer Maintenance - Attachment
- Notice Date
- 3/21/2018
- Notice Type
- Attachment
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- Department of Veterans Affairs;Great Lakes Acquisition Center (GLAC);115 S 84th Street, Suite 101;Milwaukee WI 53214-1476
- ZIP Code
- 53214-1476
- Solicitation Number
- 36C25218Q0762
- Response Due
- 3/26/2018
- Archive Date
- 4/25/2018
- Point of Contact
- Lori Eastmead
- E-Mail Address
-
Government Email
(Lori.Eastmead@va.gov)
- Small Business Set-Aside
- N/A
- Description
- The Great Lakes Acquisition Center (GLAC) in Milwaukee, WI is searching for vendors with the capability to provide maintenance services on the Eto Sterilizers, located at the William S. Middleton VA Hospital, Madison, WI. The vendor must be able to meet all the minimum requirements stated in the statement of work (listed below). Interested responsible sources must submit a summary of their capabilities to this office by 1000 CST on Monday, March 26, 2018, to include detailed description of the firm s experience in maintaining equipment, DUNS number, name and phone number of a point of contact in case further information is needed. Summaries must be submitted via email to Lori.Eastmead@va.gov. This RFI is issued solely for information and planning purposes to determine availability of qualified vendors and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. The procurement will be completed under NACIS 811219. Please note that this is not a request for proposal and the Government is seeking information for market research purposes only. The Government may or may not issue solicitation documents. Look for any further information in FedBizOpps (FBO). Telephone inquiries will not be returned. EtO STERILIZER MAINTENANCE SERVICES STATEMENT OF WORK GENERAL This contract is for the William S. Middleton Memorial Veterans Hospital, 2500 Overlook Terrace, Madison, Wisconsin, hereinafter referred to as the VA. SCOPE Equipment Covered: Equipment: EtO Sterilizer #4 Manufacturer: 3M Model: Steri-Vac 8XL S/N: 351076 Equipment: EtO Sterilizer #5 Manufacturer: 3M Model: Steri-Vac 8XL S/N: 350237 Equipment: EtO Abator #4 Manufacturer: 3M Model: 50 AN S/N: 300026 Equipment: EtO Abator #5 Manufacturer: 3M Model: 50 AN S/N: 300092 Preventative Maintenance: Complete PMs on all equipment according to manufacturer recommendations for the time periods shown below. The zone charge should be included with the PMs. The vendor shall provide an annual PM schedule to the COR within 10 business days of contract award. The vendor shall provide all labor, materials, travel, supervision, tools, test equipment, cleaning materials and facilities required for complete preventative maintenance. PM reports shall be provided to COR after each maintenance is performed and the technician will physically check out the COR or SPS designee before leaving the VA. If the vendor utilizes electronic reporting, the vendor shall provide the COR with the website link, access code, and password needed to retrieve reports within 10 business days of contract award. Repair Services: Complete repair services are included in this contract for the time periods shown below. The VA COR or designee will contact the service vendor to request repairs on equipment. The vendor shall provide all labor, materials, travel, supervision, tools, test equipment, cleaning materials and facilities required for complete repairs. The technician will certify the equipment as functional prior to leaving, provide a service report to the COR after the service, will physically check out the COR or SPS designee before leaving the VA. If the vendor utilizes electronic reporting, the vendor shall provide the COR with the website link, access code, and password needed to retrieve reports within 10 business days of contract award. Response Time: Technicians are required to respond on-site for emergency repair services within four (4) hours of receiving the call. For non-emergency repair services, the response time is twenty-four (24) hours. An emergency repair service is defined as having two (2) or more pieces of the equipment in need of repair simultaneously. All other repair services are considered non-emergency. Technician Certifications: Technicians must be certified and have up-to-date certifications on all equipment they are working on. Proof of Technician Certification shall be provided to the COR. Manufacturer Parts: Manufacturer parts or parts authorized by the manufacturer are the only parts to be used for PMs and repairs. If the part being used is not a manufacturer part, the technician shall provide manufacturer s authorization to the COR with the service report. The vendor must also have full access to all manufacturer parts and able to obtain those parts with the same lead time as the manufacturer itself. The vendor shall provide documentation of a contract with the manufacturer for all potential parts needed for the covered equipment. PAYMENTS The Contractor shall be paid, upon submission of proper invoices or vouchers, the prices stipulated herein for services rendered and accepted, less deductions, if any, as herein provided. Payments will be made quarterly in arrears. Invoices MUST INCLUDE, at a minimum, the following information: Contract Co., Purchase Order No., Item(s) covered (to include serial # s as applicable) and covered period of service. Only one original invoice will be required for each request for payment.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAGLHS/VAGLHCS/36C25218Q0762/listing.html)
- Document(s)
- Attachment
- File Name: 36C25218Q0762 36C25218Q0762.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4167032&FileName=36C25218Q0762-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4167032&FileName=36C25218Q0762-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C25218Q0762 36C25218Q0762.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4167032&FileName=36C25218Q0762-000.docx)
- Place of Performance
- Address: William S. Middleton VA Hospital;Department of Veterans Affairs;2500 Overlook Terrace;Madison, WI