Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 28, 2018 FBO #5941
MODIFICATION

47 -- Sample Cooler - Amendment 1

Notice Date
2/26/2018
 
Notice Type
Modification/Amendment
 
NAICS
332919 — Other Metal Valve and Pipe Fitting Manufacturing
 
Contracting Office
Department of the Navy, Naval Sea Systems Command, Puget Sound Naval Shipyard (PSNSY) and IMF, 1400 Farragut Ave, Puget Sound Naval Shipyard, Bremerton, Washington, 98207-5005, United States
 
ZIP Code
98207-5005
 
Solicitation Number
N4523A18Q4100
 
Archive Date
2/20/2019
 
Point of Contact
Melissa R Jones, Phone: 3604764074, Isabelito M. Cabana, Phone: 3604764025
 
E-Mail Address
melissa.r.jones@navy.mil, isabelito.cabana@navy.mil
(melissa.r.jones@navy.mil, isabelito.cabana@navy.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Vendor Questions and Answers: also added to description block N4523A18Q4100 0001_73477012_Sample Cooler_RFQ Amendment Additional Description Information- Response to Vendor Questions: With reference to the above solicitation, just a few questions: 1. Material needed, pressure, temperature, special tests, connection types, coating. Answer: --Material needed: 300 Series Stainless Steel (tubing and shell) -- Design Pressure / Temperature: - Tube = 2000 psig @ 500°C - Shell = 200 psig @ 100°C -- Connection Type: - Tube = 3/8" OD tubing inlet / outlet, with 3/8" OD tubing throughout a spiral helical heat exchanger design - Shell = 3/4" NPTF or 1-1/16-12 MS female thread (O-ring Seal Boss), both inlet & outlet -- Sample inlet temperature: - <232°C compressed water; sample outlet needs to be <38°C. at atmospheric pressure. -- No special testing or special coating required. 2. Please provide the data sheets for these sample coolers. Answer: None provided 3. Also any inputs you could provide us on the attached parameters' sheet would be helpful. Answer: None provided 4. The sample is only water at temperature <232 deg. C. what will be its pressure? Answer: Cannot provide the use pressure; that is why design pressure was provided 5. What is cooling water temperature & pressure? Also what is chloride content in cooling water? Answer: Cooling water is ambient temperature. We do not regulate or sample for chlorides in the cooling water; it is whatever comes from standard municipal fresh water supply.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVSEA/N62799/N4523A18Q4100/listing.html)
 
Place of Performance
Address: 1400 Farragut Ave, Bremerton, Washington, 98314-5001, United States
Zip Code: 98314-5001
 
Record
SN04835259-W 20180228/180226231632-49c58b01ba94d0d163af6c40383e3d02 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.