J -- Modification, Inspection, and Repair of Boilers for the VAMC Cheyenne WY 82001 - Attachment

Notice Date
2/20/2018
 
Notice Type
Attachment
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office;NCO 19, Services Team 3;1011 Honor Heights Drive;Muskogee OK 74401
 
ZIP Code
74401
 
Solicitation Number
9435
 
Response Due
2/25/2018
 
Archive Date
5/26/2018
 
Point of Contact
Lance Davis
 
Small Business Set-Aside
N/A
 
Description
Repair and Modifications of Boilers 1&2 at the Veterans Affairs Medical Center (VAMC) Cheyenne, Wyoming 82001 Brief Scope of Work (This is for information only) General: PLEASE NOTE: This is not routine boiler repair/replacement of boiler parts and/or service. Our VA Boilers have been written up for non-compliance by the State Boiler Inspector. Before the piping can be certified with an R stamp, a Historical Traveler document must be created to document all previous repairs and modifications. This work can be done only by industry specialist in Boiler Safety, modification and historical tracking to ensure that previous repairs and certification(s) of repairs are authenticated. If you feel your company can perform/complete this requirement please continue with RFI and respond accordingly. The purpose of this Scope of Work is to Repair, Modify, Inspect 2 Clever Brooks Boilers bringing them to a Compliant status by the State Boiler Inspector. Contractor will Certify all Repairs, Recover and Document all Repairs and Modifications by way of Traveler History Document. This Document will cover from installation (I have requested dates of installation for each boiler) to Certification, of the Boilers located at Bldg. 13 at the Cheyenne VA Medical Center (VAMC). Scope of Work: This application is to have our boiler piping properly certified and stamped to pass boiler inspection. Before the piping can be certified with an R stamp, a Historical Traveler document must be created to document all repairs and modifications. This work can be done only by industry specialist in Boiler Safety, modification and historical tracking to ensure that repairs and certification of repairs are authenticated. It is believed that these requirements are highly specialized in nature and are not readily available on the open market. This project is vital to Safety Standards and Operational compliance of the Boiler Plant located at the Cheyenne VA Medical Center. Gathering of documentation and on location visits to establish repair methodology and confirm code compliance. Gathering all documents from Cleaver Brooks. Each boiler will require two visits by the Authorized Inspectors Agent (AIA). Preform on location all repairs and modifications First day, isolate the piping, remove the valve, clean the area, perform interior inspection as required, clean the threaded areas and gather the correct material for installation. Day 2, install the pipe and flange and install new gasket at flange as may be required. Day 3, Hydro Test the boilers as a test Hydro prior to calling inspector for final Hydro. Day 4, final Hydro Testing and inspection with AIA, complete paper work. Day 5 install boiler tags, complete copies of paper work and binder, provide to customer. Supervisor as required 3 days total. Materials/Equipment: Pipe, Pipe compound, gaskets for flanges, fasteners as may be required, consumables, paper copies and binders supplied to customer, badge plates to be attached to boiler. Description of Supplies/Services Required to Meet the Agency s Needs: When the boilers were installed in 2000 they were not installed per Boiler code. To correct this non-compliance, the following has to be completed: Research and gather documents from Clever Brooks to assemble a certified Traveler for each boiler to document the history of modifications and repairs to each boiler. Each Boiler will be required to undergo inspections and testing by Authorized Inspectors Agent (AIA). Boiler repairs will require 2 certified boiler repairmen for 5 Days and an Inspector for 2 days. Sole Source Justification We believe the complexity and technical aspects involved to certify past boiler repairs and to re-certify the boilers for use creates a very limited pool of firms capable of doing the work. Many of the special-duty shops have P stamps and can build boilers, but very few have R stamps that can retro-certify past boiler repairs. 4. Contractor Qualifications: Must be ASME Boiler and Pressure Vessel Certified and accredited as repair Specialist. 5. Requirements: Contractor will be required to provide all materials, supplies, equipment, tools labor and supervision necessary to provide for every aspect of the project. 6. Utility Shutdowns: A. No utility shutdown may occur without express written consent of the COR. B. Except in emergency cases, any interruption, or potential interruption of power to the Cheyenne VAMC will require a minimum of two weeks written notice prior to the shutdown. Extended shutdowns may have to occur on weekends. 7. Security Requirements: All Contractor personnel shall check in daily with the VA Police Office to obtain a Contractor s Identification Badge. The badge must be worn visibly upon their person, between the height of the waist and shoulders. The badges shall be returned at the completion of service each day. Two forms of current federal, state issued identification are required to obtain a badge. 8. Safety: All work is to be performed in accordance with all Federal, State, OSHA, and Cheyenne VAMC safety standards. Location of performance Cheyenne Health Care System 2360 East Pershing Blvd. Cheyenne, WY 82001 IMPORTANTR NOTE: This RFI (Request for Information) is for information only; no award will be made off of this RFI. Please communicate via e-mail to Lance.Davis2@va.gov by COB February 25, 2018 as to your company s ability to perform service per this brief Scope of Work. If interested please provide the following: Please state your company s business size Please provide DUNS number Do you have a FSS/GSA contract that includes this service Provide FSS/GSA contract number if applicable
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/9435/listing.html)
 
Document(s)
Attachment
 
File Name: 9435 9435.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4096554&FileName=9435-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4096554&FileName=9435-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Cheyenne Health Care System;2360 East Pershing Blvd.;Cheyenne WY
Zip Code: 82001
 
Record
SN04828068-W 20180222/180220231248-b319b11075c5ebc8959eae3f0081ec16 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.