SOLICITATION NOTICE
N -- Removal/Disposal of Boiler, Mach series C2000H
- Notice Date
- 2/16/2018
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Health and Human Services, Indian Health Service, Navajo Area Office, PO Box 9020, Window Rock, Arizona, 86515
- ZIP Code
- 86515
- Solicitation Number
- KHCRD-18
- Point of Contact
- Rosie Daugomah, Phone: 9286974024
- E-Mail Address
-
rosie.daugomah@ihs.gov
(rosie.daugomah@ihs.gov)
- Small Business Set-Aside
- N/A
- Description
- This project will replace a defective Harsco Industrial; Patterson-Kelly C2000H MACH gas fired boilers within the Navajo Reservation at Kayenta, Arizona. The Hospital is located off US Highway 1 60, 7/2 mile south of MP 394.3. This is a new hospital facility. There are (5) Patterson-Kelly Boilers which one boiler is leaking. This project requires vendor's expertise for a turnkey project to Engineer, Remove, Furnish, and install new boiler. Kayenta Service Unit is at a remote location; the nearest town is a two-hour drive. Contractor must be knowledgeable with current system in place and knowledgeable to integrate control to existing DDC system. This project will replace a defective Harsco Industrial; Patterson-Kelly C2000H MACH gas fired boilers within the Navajo Reservation at Kayenta, Arizona. The Hospital is located off US Highway 1 60, 7/2 mile south of MP 394.3. This is a new hospital facility. There are (5) Patterson-Kelly Boilers which one boiler is leaking. This project requires vendor's expertise for a turnkey project to Engineer, Remove, Furnish, and install new boiler. Kayenta Service Unit is at a remote location; the nearest town is a two-hour drive. Contractor must be knowledgeable with current system in place and knowledgeable to integrate control to existing DDC system. Contractor must be knowledgeable and experience of harsco Industrial; Patterson-Kelly C2000H MACH gas fired boiler installation at the hospital. Existing working four boiler must operate during removal and installation of defective boiler. Contractor must insure a safe and factory recommended installation and testing to replace Patterson-Kelly C2000H Mach Boilers at the Health Care Center and Maintenance Facility. Contractor must provide all tools and it is responsibility for contractor to reconnect all plumbing systems and controls. KHC will retain removed boiler and parts. Specification of existing gas-fired heating boiler: Model: C-2000H Serial No. H845-1 3-9964 Input Rating Max. 2,000,000 BTU/hr Output Rating. 7,920,000 BTU/hr Input Rating Mm. 400,000 BTU/hr Mm Relief Valve Cap. 1920 lbs/hr Electrical 1 20V, 60Hz, 1 Ph Venting Category II or IV Fuel. Natural Gas Gas Pressure (Max / Mm.) 1 4..0 inches WC / 3.5 inches WC Total Amperage 1 2 Amps
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/IHS/IHS-Navajo/KHCRD-18/listing.html)
- Place of Performance
- Address: Kayenta Health Center, U.S. Highway 160, South MP 394.3, Kayenta, Arizona, 86033, United States
- Zip Code: 86033
- Zip Code: 86033
- Record
- SN04826238-W 20180218/180216230817-eb95f7e46fac064c8634e136d48dfda8 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |