Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 12, 2018 FBO #5894
SOLICITATION NOTICE

44 -- Compressor Bed

Notice Date
1/10/2018
 
Notice Type
Presolicitation
 
NAICS
332420 — Metal Tank (Heavy Gauge) Manufacturing
 
Contracting Office
Department of Energy, Sandia Corp. (DOE Contractor), Sandia National Laboratories, PO Box 5800, MS: 0115, Albuquerque, New Mexico, 87185
 
ZIP Code
87185
 
Solicitation Number
KT012018-00
 
Archive Date
2/10/2018
 
Point of Contact
Kayla Terry,
 
E-Mail Address
kterry@sandia.gov
(kterry@sandia.gov)
 
Small Business Set-Aside
N/A
 
Description
This is an inquiry only. At this time, National Technology and Engineering Solutions of Sandia, LLC (NTESS) does not have a firm requirement or budget for the products or services requested herein. Please furnish the name, title, email, and phone number of the person(s) designated by your company with decision authority to discuss your response. STATEMENT OF WORK Four pressure vessels shall be fabricated from either A-286 or Nitronic 50. Minimum of Two of the vessels must be rated to 900 bar and the other two rated to 300 bar (or all four may be rated to 900 bar depending on lead time and cost). Operating temperature shall be between 10°C and 175°C. The maximum weight of each vessel is 300 lbs. The internal geometry of the vessel should be 6.5" ID with an inside length of 17.5". A 0.25" thick Teflon liner shall insulate all sides of the internal cavity. Helical tubing shall be inserted in the cavity, thus requiring two holes through the pressure vessel lid. These tube penetrations require a static seal design. A third lid penetration shall be required for gas inlet connection. DESIGN DETAILS 4 vessels: 2 rated to 900 bar, 2 rated to 300 bar; operating temperature shall be between 10°C and 175°C; Maximum weight of each vessel is 300 lbs. PRESSURE VESSEL Material options: A-286 or Nitronic 50 Internal dimensions: 6.5" ID, 17.5" internal length Two static seal penetrations for 0.75" diameter tubing One gas inlet penetration/connection PRESSURE SEALS Lid seals to be determined by manufacturer Seals for the.075 tubing: Recommendation is Bal Seal high pressure/High temperature static seal spring loaded with backup ring; Other seal designs per manufacturer suggestion will be considered Gas Inlet Penetration: Assume medium pressure cone and thread connection unless other suggestion per manufacturer
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/SNL/SN/KT012018-00/listing.html)
 
Record
SN04786232-W 20180112/180110231053-0dfe23620086cd7822b2ee9f2f87970b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.