Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 11, 2018 FBO #5893
SOURCES SOUGHT

B -- Energetic Materials Sensitivity and Reactivity Testing Services

Notice Date
1/9/2018
 
Notice Type
Sources Sought
 
NAICS
541380 — Testing Laboratories
 
Contracting Office
Department of the Army, Army Contracting Command, ACC - RI (W52P1J), 3055 Rodman Avenue, Rock Island, Illinois, 61299-8000, United States
 
ZIP Code
61299-8000
 
Solicitation Number
W52P1J-18-T-3013
 
Point of Contact
Valerie S. McDonald, Phone: 3097820467, Vicki L. Ahlgrim, Phone: 3097823220
 
E-Mail Address
valerie.s.mcdonald.civ@mail.mil, vicki.l.ahlgrim.civ@mail.mil
(valerie.s.mcdonald.civ@mail.mil, vicki.l.ahlgrim.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
Tooele Army Depot has a requirement for on-site performance of sensitivity and reactivity testing services of propellant, explosives and pyrotechnic (PEP) materials and/or articles. Testing will include laboratory-scale, small scale and full scale. Testing shall be directed and witnessed by explosive test personnel approved/certified by the Associate Administrator of the U.S. Department of Transportation (DOT), Pipeline and Hazardous Materials Safety Administration (PHMSA) to examine and make recommendations concerning explosives/energetic material in accordance with 49 CFR 173.56(b)(1). Interested offerors should be aware that Material Characterization Testing is required; the Department of Transportation certification requirement is ten years experience for the conduct of the described testing. **REQUIRED EQUIPMENT, AS LISTED BELOW, FOR THE FULL RANGE OF REQUIRED TESTS SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE LOCATED AT THE TOOELE ARMY DEPOT TESTING SITE FOR THE DURATION OF ANY CONTRACT AWARDED** THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE REQUIRED STORAGE ACCOMMODATIONS FOR THE REQUIRED EQUIPMENT.** **THE GOVERNMENT WILL NOT FACILITIZE THE CONTRACTOR FOR THE COSTS OF THE REQUIRED EQUIPMENT OR FOR THE STORAGE ACCOMMODATIONS FOR THE REQUIRED EQUIPMENT.** Any contract awarded for the required services will be a 'requirements-type' contract as described at FAR 52-216-21. For any test equipment designed and fabricated by the contractor for use under task orders issued against any requirements contract for the required services, the contractor will make available to the Government, and grant the Government the right to use without restriction, all drawings, specifications, or other data necessary for fabrication and operation of said equipment. Equipment Required: *Allegany Ballistics Laboratory (ABL) Friction Machine -Test apparatus that simulates friction stimuli and generates inprocess characteristic curves for explosive materials. Also valid for UN Test Series 3 Friction Testing. *ABL Friction Machine Tooling- Inventoried/spare friction plates/wheels in order provide fluid non- stop testing for large projects. *Modified Bureau of Mines (MBOM) Impact Machine- Test apparatus that simulates impact stimuli and generates inprocess characteristic curves for explosive materials. Also valid for UN Test Series 3 Impact Testing. *MBOM Impact Machine Tooling- Inventoried/spare impact anvils/inserts for various tooling (Type 12, MBOM, BOE) in order provide fluid non-stop testing for large projects. *ABL Electrostatic Discharge (ESD) Machine- Test apparatus that simulates ESD stimuli and generates inprocess characteristic curves for explosive materials. *ABL ESD Machine Tooling- Inventoried/spare sample holder/needles in order provide fluid non-stop testing for large projects. *BAM Friction Machine- Test apparatus that simulates friction stimuli and generates relative comparison data for explosive materials. Also valid for UN Test Series 3 Friction Testing. *BAM Friction Machine Consumables- Inventoried/spare plates/pins in order provide fluid non stop testing for large projects. *Cabinets, tables, lockers, explosive magazine- Prep Bay 3 - storage cabinets, lockers, prep tables, day explosive magazine. *High Speed Camera System- GoDetect - high speed camera detection system, proprietary current trigger, photoelectric sensors on equipment, custom camera mounts for equipment. *Roller Tool Boxes w/ Tools- (2) large roller tool boxes filled with tools, power tools, temperature gun, weather meter, assortment of tools. *Bay 2 - Sensitivity Lab- Construction of sensitivity lab (HVAC, sheetrock, paint, humidity control, Air Evacuation Fan, rollup garage door, grounding system). *Prep Tables- Table for ESD Machine, material prep tables. *Microtome- Used to cut cast propellant to specified thickness. *TV's- (3) TV's & mounts for remote viewing of testing. *High Voltage Voltmeter Voltmeter for calibrating ESD machine (10K volts). *Gas Analyzer- CO, CO2, Nox gas detection system (including custom enclosures for equipment) for sensitivity testing. Thermal Lab *SBAT/VTS- Simulated Bulk Auto-Ignition Apparatus & Vacuum Thermal Stability includes Data Acquisition's (DAQ's). *Ovens- Programmable ovens for Thermal Stability Testing (UN Series 3/4). *Thermal Lab Construction- Roofing, paint, slide-up door, circulation fans (completion of building). *Bldg. 1378- HVAC System. *Koenen Apparatus- UN Series 1/2 test apparatus. *Koenen Consumables- Inventoried/spare collars, orifices, and Koenen tubes in order provide fluid non-stop testing for large projects. *Time/Pressure Apparatus- UN Series 1/2 test apparatus and ancillary equipment. *Koenen Metal Enclosure- Enclosure to house Koenen apparatus during testing. *Metal Enclosure- Exclusion from Class 1 enclosure for measuring smoke output. *UPS- Units Uninterrupted Power Supplies (6). *Laptops- (4) for SBAT/VTS, Ovens. *DAQ Modules- (3) Data Acquisition for ovens. External Fire Area/Bermed Area *Concrete Pad- 50'x50' concrete pad for external fires. *Burn Pan- 8'x8' burn pan. *Burn Pan 12'x12' burn pan. *Portable Sony Handycams- (6) Sony Handycam Cameras for testing videos. *Power Over Ethernet (POE) Cameras- (4) Power over ethernet (POE) cameras for long term video recording (8 TB). *Liberty DAQ System- Data Acquisition System (100,000 S/sec, 8 channels). *Pencil Probes- Side on overpressure sensors [(6) 0-50 psi, (8) 0-500 psi]. *Heat Flux Sensors- (6) heat flux sensors. *Heat Flux DAQ/Computers- Data Acquisition System and computers for Heat Flux measurement. *Conditioning Chamber- Conditioning Chamber for specialized temperature control testing. *Concrete Blocks- Portable Concrete blocks for barriers (18). *Fiber Optic Cable Runs- Fiber Optic Cable to Berm/External Fire Area. *Firing Lines- Firing Lines to Berm/ External Fire Area. *Witness Screen Stands- Stands to hold external fire witness screens. *Oscilloscope- Oscilloscope. *Pin Mixer- Pin Mixer for SLSGT and similar. *Network Hardware Network Gear (switches, cell signal booster kit, remote operation system/laptop, etc.). 12-Meter Drop Tower Area *Concrete Pad- standard drop tower pad (6'x6'x3'). *Steel Plate- 3' steel plate for standard drop tower pad. *Grove Crane- Crane for heavy/large items. *Crane Protective Enclosure- protective enclosure for crane in the event of an explosion. *Concrete Pad- 24' x 8' concrete pad (precast) - crane location. *Steel Plates- steel plates for concrete pad - crane location. *Winch- winch for raising smaller packages. *Poles- telephone poles for 12-meter height test. Explosive Magazines *Magazine A- A compatibility Group Explosive Magazine. *Magazine B- B compatibility Group Explosive Magazine. *Magazine C- C compatibility Group Explosive Magazine. *Magazine D,E- G compatibility Group Explosive Magazines (2). *Boosters- Pentalite/ Comp B Booster Inventory for testing. *Initiation Detonators- #8 caps, electric matches, drop tower detonators. Connex's *Pipe- Large quantity of UN Gap, NOL Gap, Critical Height, Critical Diameter, ANE Gap pipes, etc. *Witness Plates- UN Gap, NOL Gap, small scale burn witness plates. *TC Wires- Spools full of thermocouple wires. *Coax Cable- Spools full of coax cable (2000 feet). *O.1 Test Kit- Oxidizing Solids Kit. *Dangerous When Wet Kit- glassware & necessary hardware for 'Dangerous When Wet' test. *External Fire Witness Screens- (3) sets of witness screens. *Drop Tower Kit- Quick release devices. *Crane Rigging- Slings, Sling Rings, Clevis', cables/hooks. *Heating Stoves- Custom stoves for firework testing. *Misc.- Ladders, post pounder, sledge hammer, rakes, shovels, t-posts, spare cables/ wires, spare ropes. This notice neither constitutes a Request for Proposal, nor does it restrict the Government to an ultimate acquisition approach. It should not be construed as a commitment by the Government for any purpose nor will the Government pay for information solicited. Responses to this Sources Sought notice will be used by the Government to make appropriate acquisition decisions. Responses must include the following: 1) Company name and address 2) Business size classification (Small, Small Disadvantaged (SDB), 8(a), Woman-owned Small Business (WOSB), Veteran Owned Small Business (VOSB), Service Disabled Veteran Owned Small Business (SD-VOSB), Historically Underutilized Business Zone (HUBZone) small businesses including the number of employees and the number of years in business. 3) Interested offerors shall provide a summary of their capabilities and detailed description of past performance (within the past 3 years) of similar efforts to Valerie McDonald at valerie.s.mcdonald.civ@mail.mil.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/deb47f07d8e02493c551f0f9cff7ffcd)
 
Place of Performance
Address: 1 Tooele Army Depot, Tooele, Utah, 84074, United States
Zip Code: 84074
 
Record
SN04785496-W 20180111/180109231657-deb47f07d8e02493c551f0f9cff7ffcd (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)