DOCUMENT
66 -- Veterinary Medical Unit Equipment 01 (VMU) Southeast Louisiana Veterans Healthcare System 2400 Canal Street New Orleans, LA 70119 - Attachment
- Notice Date
- 1/8/2018
- Notice Type
- Attachment
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Southeast Louisiana Veterans HCS;Network Contracting Office 16;1555 Poydras Street STE 1308;New Orleans LA 70112
- ZIP Code
- 70112
- Solicitation Number
- 36C25618Q0190
- Response Due
- 1/17/2018
- Archive Date
- 4/26/2018
- Point of Contact
- C. Robert Oravetz
- E-Mail Address
-
k
- Small Business Set-Aside
- Veteran-Owned Small Business
- Description
- This is a notice to all offerors that FedBizOpps Combined Synopsis Solicitation 36C25618Q0190 is being amended to add/change the following: Change Sections 2.5.3, 2.5.4, and 2.6 in Statement of Work to read the following. (Changes to these sections are highlighted in yellow) 2.5.3 Description: Anesthesia, Gas, Isoflurane, W/Induction Chamber, 4 each, configured in Research building rooms: 4P318C. Suggested Manufacturer Brand Name: Parkland Scientific, Model V3000PK, or equivalent. Specifications/Salient Characteristics: Approximate sizes may vary from unit to unit Table Top Anesthesia Stand w/ flowmeter & O2 Flush Isoflurane Vaporizer Small Dual Induction Kit w/ 6"x8"x4" Chamber & Dual diverter valves (approximate size) Large Dual Induction Kit w/ 8"x12"x4" Chamber & Dual diverter valves (approximate size) Small Rodent Non-Rebreathing Circuit with Nose Cone & diaphragm Hoses & connectors for nose cone (No chamber needed). Scavenger circuits w/ replaceable evacuation filter cartridge No less than 4 to 6 Way splitter manifolds 2.5.4 Description: Table Top Isoflurane Anesthesia System, Veterinary, 4 each, configured in Research building rooms: 4P318C, 4P321, 4P322, 4P333. Suggested Manufacturer Brand Name: Parkland Scientific, Model V3000PS, or equivalent. Specifications/Salient Characteristics: Approximate sizes may vary from unit to unit Table Top Anesthesia Stand w/ flowmeter & O2 Flush Isoflurane Vaporizer Small Rodent Non-Rebreathing Circuit with Nose Cone & diaphragm Hoses & connectors for nose cone (No chamber needed). Scavenger circuits w/ replaceable evacuation filter cartridge Oxygen Supply Hose 6' w/ DISS Connectors 2.6 DELIVERY AND CONFIGURATION/INSTALLATION 2.6.1 DELIVERY 2.6.1.1 Contractor shall deliver all equipment to the Southeast Louisiana Veterans Health Care System (SLVHCS), Central Energy Plant building, 2401 Tulane St, New Orleans, LA 70119 beginning on May 1st, 2018. 2.6.1.2 Deliver materials to job in manufacturer's original sealed containers with brand name marked thereon. 2.6.1.3 Package to prevent damage or deterioration during shipment, handling, storage and installation. Maintain protective covering in place and in good repair until removal is necessary. 2.6.1.4 Deliver specified items only when the site is ready for installation work to proceed. 2.6.1.5 Store products in dry condition inside enclosed facilities. 2.6.1.6 Any government requested delayed delivery up to 90 days after initial award delivery date, shall be at no additional cost to the Government. 2.6.1.7 A pre-delivery meeting will be conducted 60 days prior to initial award delivery date for verification of delivery and installation dates. If a meeting is not held delivery and installation dates may be established through e-mail communication between authorized government and contractural representatives. 2.6.1.8 Delivery and Installation will be coordinated through the COR. 2.6.2 CONFIGURATION/INSTALLATION 2.6.2.1 All equipment shall be floor mounted by contractor upon delivery unless otherwise noted above. 2.6.2.2 Install/Configure all equipment to manufacturer s specifications maintaining Federal, and Local safety standards 2.6.2.3 Installation/Configuration must be completed by June 15th, 2018. All work shall be completed between 8:00 a.m. and 4:30 p.m. Monday Friday. All federal holidays, excluded. Federal holidays are available at the Federal Holiday OPM Site. 2.6.2.4 If there is an operational conflict with installation, night or weekend installation may be required. Government will provide a 72 hours' notice of change of installation hours. 2.6.2.5 The contractor shall coordinate all deliveries, staging areas, installations, and parking arrangements with the COR. 2.6.2.6 The Contractor shall remove all related shipping debris and cleanup any construction associated with delivery and installation of the specified items. Contractor shall remove all packaging from the SLVHCS premises. The Contractor shall be responsible for any damage to the building that occurs due to Contractor error or neglect.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/NOrVAMC/VAMCCO80220/36C25618Q0190/listing.html)
- Document(s)
- Attachment
- File Name: 36C25618Q0190 36C25618Q0190_4.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4003154&FileName=36C25618Q0190-004.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4003154&FileName=36C25618Q0190-004.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 36C25618Q0190 36C25618Q0190_4.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=4003154&FileName=36C25618Q0190-004.docx)
- Record
- SN04784204-W 20180110/180108231612-e15b24e4321c0c179cde5c78eedca92a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |