Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 06, 2018 FBO #5888
SOURCES SOUGHT

Z -- Chiller Replacement

Notice Date
1/4/2018
 
Notice Type
Sources Sought
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Agricultural Research Service - Eastern Business Service Center
 
ZIP Code
00000
 
Solicitation Number
1232SC18R0006
 
Archive Date
1/27/2018
 
Point of Contact
Joshua Dobereiner, Phone: 309-681-6410
 
E-Mail Address
josh.dobereiner@ars.usda.gov
(josh.dobereiner@ars.usda.gov)
 
Small Business Set-Aside
N/A
 
Description
THIS IS FOR MARKET RESEARCH PURPOSES ONLY, NOT A REQUEST FOR PROPOSAL OR SOLICITATION. The United States Department of Agriculture (USDA), Agricultural Research Service (ARS) is conducting market research to support the Eastern Regional Research Center requirement for a chiller replacement. USDA/ARS is seeking business sources, including small businesses, service-disabled veteran-owned small businesses, HUBZone small businesses, 8(a) certified companies and other than small businesses. The associated North American Industry Classification System (NAICS) Code is 238220, Plumbing, Heating and Air-Conditioning Contractors. The small business size standard is $15 million. The following information is provided to assist USDA/ARS in conducting market research to identify potential contractors for this effort: The government is seeking capability statements from businesses capable of meeting the below performance requirements: • Removal of existing 500 ton water chiller and replace with a new 500 ton magnetic drive chiller. • Modifications to the condenser water and chilled water piping to achieve the replacement. • Electrical work consisting of removing the existing chiller from the 4160V system and powering the new chiller from an existing 480V motor center. • Modification of the existing refrigerant monitoring system and adding an exhaust fan and ductwork to refrigerant evacuation system. Place of Performance: Eastern Regional Research Center 600 East Mermaid Lane Wyndmoor, PA 19038 Respondents shall furnish sufficient technical information necessary for the Government to conclusively determine that they are capable of meeting the technical requirements identified above. Firms believing they can meet the requirements are encouraged to respond electronically with no less than the following information: • Business name, DUNS number, business address, business website, business size status (i.e., SB, VOSB, SDVOSB, HUBZone SB, SDB, WOSB, LB), point of contact name, mailing address (if different from business address), phone number and email address; • Sufficient descriptive literature that unequivocally demonstrates that offered services will meet or exceed above specifications; • Descriptive material necessary for the government to determine whether the service offered meets the technical requirements; • If a large business, provide if subcontracting opportunities exist for small business concerns. The government is not responsible for locating or securing any information, not identified in the response. Interested Parties must respond with capability statements no later than 1:00 PM Central Standard Time on Friday, January 12, 2018. Capability statements shall be sent electronically to josh.dobereiner@ars.usda.gov. Notice of Intent: Responses to this sources sought announcement will assist the Government in determining whether or not any future requirement similar to this one should be set aside for small business, made available to full and open competition or procure through sole-source acquisition procedures. Disclaimer and Important Notes: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in FedBizOpps. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality: No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/b417d16545c8ef13f8ce8e72d5653aac)
 
Place of Performance
Address: 600 East Mermaid Lane, Wyndmoor, Pennsylvania, 19038, United States
Zip Code: 19038
 
Record
SN04781558-W 20180106/180104231018-b417d16545c8ef13f8ce8e72d5653aac (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.