DOCUMENT
65 -- Electromyography (EMG) Wireless System - Attachment
- Notice Date
- 11/6/2017
- Notice Type
- Attachment
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 20;5115 NE 82nd Ave, Suite 102;Vancouver WA 98662
- ZIP Code
- 98662
- Solicitation Number
- 9076
- Response Due
- 11/10/2017
- Archive Date
- 11/20/2017
- Point of Contact
- Gregory Watson
- Small Business Set-Aside
- N/A
- Description
- Page 3 of 3 Special Notice Request for Information Only The Department of Veterans Affairs, NCO20 is looking for sources of the following. STATEMENT OF WORK/SALIENT CHARACTERISTICS Department of Veterans Affairs Seattle VA Medical Center Overview: Seattle VAMC requires Prospective contractors to provide the following Delsys Trigno Wireless EMG + IMU System:. Brand Name or Equal per FAR 52.211-6 Brand Name or Equal to DELSYS INC. CLIN 001 1 EA DS:Wireless System:(T01D-16 IM): Trigno Wireless EMG + IMU System: Trigno Digital Base Station, 16*Trigno EMG + IMU Sensor, 2*Trigno Sensor Adhesive Interface (pkg. 80), Trigno Power Adapter, USB Cable (5 ft.), Delsys Software DVD (1 EMGworks 4.X Pro License) & User's Guide. CLIN 002 8 EA SP:W01C Trigno Snap-Lead EMG Sensor CLIN 003 4 EA SP:W01J Trigno Miniature Head Sensor CLIN 004 4 EA SP:W01K Trigno +/- 5V Analog Adapter CLIN 005 2 EA SP:W01G Trigno Load Cell Adapter Sensor CLIN 006 1 EA DS:Trigger Module:(U02) Trigger Module Package: Trigger Module (Bagnoli/Trigno) & Product Guide. CLIN 007 1 EA SC:P06 Trigno Sensor Charge Station CLIN 008 1 EA SC:P05 Trigno Power Adapter Objective: Our objective is to provide Seattle VAMC with necessary equipment to provide the best care for our veterans. Salient Characteristics The Government requires the following characteristics to be met: The wireless EMG system must satisfy the following requirements: EMG System Integrated tri-axis accelerometers: Operating range: 40m Minimum number of sensors: 16 Inter-sensor delay: 0 secs EMG signal range: ±5V Baseline noise: < 0.5mV RMS Motion artifact suppression Snap-on sensors Clamp style connector leads Built-in accelerometer Range: 40 m Battery life: 8 hours Mini sensors Operating range: 20m Power consumption: <65 mW Size: <30x15x10 mm Baseline noise: <0.75 uV (rms), r.t.i. Analog adapters Compatible with Biodex and Humac systems Transmission: 2.4 GHz Adapters for load cells Support a wide variety of load cells Variable gain settings Range: 40 m Battery life: 8 hours Compatible with the existing software and hardware Vicon Motion Capture System This is not a request for competitive quotes; however, any firm that believes it can meet these requirements vendor may give written notification to the Contracting Officer within 7 days from the date of the publication of this synopsis. Any response to this notice must show clear and convincing evidence that competition would be advantageous to the Government. Only authorized representatives of the manufacturer will be considered. Equipment must be new, no used or refurbished equipment accepted. Responses are due by 11/10/2017 1:00 pm EST. In accordance with FAR and VAAR Part 8 and/or 13, this notice document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-95, 19 Jan 2017. The North America Industry Classification System Code (NAICS) is 334516. Business Size Standard is 1000 Employees. Contracting Office Address: Department of Veterans Affairs NCO 20 Acquisitions 5115 NE 82nd Ave Suite 203 Vancouver, WA 98662 Contracting POC Gregory Watson 360-553-7602 gregory.watson2@va.gov DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PoVAMC/VAMCCO80220/9076/listing.html)
- Document(s)
- Attachment
- File Name: 9076 9076.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3892532&FileName=9076-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3892532&FileName=9076-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: 9076 9076.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3892532&FileName=9076-000.docx)
- Record
- SN04732794-W 20171108/171106231251-f11bb8f07fe42306baf73508d0358c79 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |