Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 09, 2017 FBO #5769
DOCUMENT

66 -- Electrical Safety Analyzer - Attachment

Notice Date
9/7/2017
 
Notice Type
Attachment
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
Department of Veterans Affairs;NCO 16 (90C/NLR);2200 Fort Roots Drive, Bldg 41, Room 219;North Little Rock AR 72114 1706
 
Solicitation Number
VA25617N1454
 
Response Due
9/8/2017
 
Archive Date
11/7/2017
 
Point of Contact
Bailey M Long
 
E-Mail Address
7-1026<br
 
Small Business Set-Aside
N/A
 
Description
This is not a solicitation announcement. This is a sources sought notice only. The purpose of this notice is to gain knowledge of potential qualified sources and their size classification (service disabled veteran owned small business, veteran owned small business, hub zone, 8(a), small disadvantage business, woman-owned, small business, or large business) relative to NACIS 334515 (size standard 750 employees). Responses to this notice will be used by the Government to make appropriate acquisition decisions and are not considered adequate responses to a potential future solicitation announcement. The Central Arkansas Veterans Healthcare System is seeking sources that can supply four Electrical Safety Analyzers. The government intends to award a single contract to purchase the goods listed. Responses to this request should include a capability statement, and three (3) customer references to which you have provided similar products. Responses should also include company name, address, point of contact, size of business pursuant to the following questions: (1) is this service available under a federal supply schedule (GSA)? If yes, please provide the contract number. (2) Do you directly provide these services? (3) Is your business large or small? (4) If small, does your firm qualify as a small, emerging business, or small disadvantaged business? (5) If disadvantaged, specify under which disadvantaged group and if your firm is certified under Section 8(a) of the Small Business Act. (6) Is your firm a certified hub zone firm? (7) Is your firm a woman-owned or operated business? (8) Is your firm a certified Service-Disabled Veteran Owned Small or veteran owned small business? Responses to this notice shall be emailed to Bailey Long, email address bailey.long@va.gov. This notice will close and responses are due no later than 11:00 A.M. EDT September 8, 2017. Telephone responses will not be accepted. Responses must be received via e-mail. This notice is to assist the VA in determining sources only. A solicitation is not currently available, if a solicitation is issued it will be announced at a later date. Statement of Work/Salient Characteristics for Electrical Safety Analyzer for the Biomedical Engineering Section Request four electrical safety analyzers to perform electrical safety and performance testing for medical equipment. At a minimum, the electrical safety analyzers must include the following characteristics to be considered acceptable for purchase. 120 volt operating voltage (90 V ac to 132 V ac RMS) Voltage Available Test Selections Mains, Accessible, and Point to Point Mains Range(s) 120 V model: 90 V ac to 132 V ac RMS Accuracy ± (2 % of reading + 2 LSD) Accessible Range 0 V ac to 300 V ac RMS Accuracy ± (2 % of reading + 2 LSD) Point to Point Range 0 V ac to 300 V ac RMS Accuracy ± (2 % of reading + 2 LSD) Earth Resistance Resistance Tests Earth Resistance and Point to Point Two-Terminal Mode Test Current Range & Accuracy >200 mA ac : 0 ohms to 2 ohms ± (2 % of reading + 0.015 ohms) 10 to 25 A ac typical : 0 ohms to 0.2 ohms ± (2 % of reading + 0.015 ohms) 0.2 ohms to 2.0 ohms ± (5 % of reading + 0.015 ohms) Four-Terminal Mode Test Current Range & Accuracy >200 mA ac : 0 ohms to 2 ohms ± (2 % of reading + 0.005 ohms) 10 to 25 A ac typical: 0.0 to 0.2 ohms ± (2 % of reading + 0.005 ohms 0.2 to 2.0 ohms ± (5 % of reading + 0.005 ohms) Equipment Current Mode AC RMS Range/Accuracy 0 A to 20 A : ± 5 % of reading ± (2 counts or.2A, whichever is greater) Duty Cycle 15 A to 20 A, 5 min on/5 min off 10 A to 15 A, 7 min on/3 min off 0 A to 10 A continuous Leakage Current Modes * AC + DC (True RMS) AC only DC only Crest factor = 3 Ranges 0 µA to 199.9 µA 200 µA to 1999 µA 2 mA to 10 mA Frequency Response Accuracy DC to 1 kHz : ± (1 % of reading + 1 µA or 1 LSD, whichever is greater) 1 kHz to 100 kHz : ± (2 % of reading + 1 µA or 1 LSD, whichever is greater) 100 kHz to 1 MHz : ± (5 % of reading + 1 µA or 1 LSD, whichever is greater) MAP Voltage Additional residual leakage up to 4 µA @ 120 V ac, and 8 µA @ 240 V ac Leakage Tests Earth (ground wire) Chassis (enclosure) Patient (lead to ground) Patient Auxiliary (lead to lead) Mains on Applied Part (lead isolation) Differential Leakage Ranges 50 µA to 199 µA 200 µA to 1999 µA 2 mA to 20 mA Accuracy ± 10 % of reading ± (2 counts or 20 µA, whichever is greater) Insulation Resistance Ranges/Accuracy 0.5 M-ohms to 20 M-ohms : ± (2 % of reading + 2 counts) 20 M-ohms to 100 M-ohms : ± (7.5 % of reading + 2 counts) Source Test Voltage 500 V dc, 250 V dc Insulation Resistance Tests Mains-PE, AP-PE, Mains- PE, Mains-NE (non-earthed accessible conductive part) and AP- NE (non-earthed accessible conductive part) Maximum Load Capacitance 1 µF ECG Performance Waveforms Accuracy ± 2 % ± 5 % for amplitude of 2 Hz Square wave only, fixed @ 1 mV Lead II configuration Waveforms / Rates ECG Complex (BPM) : 30, 60, 120, 180, and 240 Ventricular Fibrillation Square wave (50 % duty cycle) (Hz) 0.125 and 2 Sine wave (Hz) 10, 40, 50, 60, and 100 Triangle wave (Hz) 2 Pulse (63 ms pulse width) 30 and 60 Power Ratings Mains Voltage Outlet 120 V ac : 230 V ac Mains Voltage Inlet Power Range 90 V ac to 132 V ac RMS : 180 V ac to 264 V ac RMS Maximum Current 20 A : 16 A (50, 60 Hz) Other required items Operator s Manual (CD Rom or hard copy) Getting started guide (hard copy) Test Lead Set Test Probe Set Alligator Clip Set
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VACAHCS598/VACAHCS598/VA25617N1454/listing.html)
 
Document(s)
Attachment
 
File Name: VA256-17-N-1454 VA256-17-N-1454_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3780933&FileName=VA256-17-N-1454-001.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3780933&FileName=VA256-17-N-1454-001.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Overton Brooks VA Medical Center;510 E. Stoner Ave.;510 E. Stoner Ave.;Shreveport, LA
Zip Code: 71101
 
Record
SN04667011-W 20170909/170907233042-a780067a618b2f86ea9526543e243122 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.