DOCUMENT
65 -- Intra Aortic Balloon Pump - Attachment
- Notice Date
- 6/30/2017
- Notice Type
- Attachment
- NAICS
- 423450
— Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
- Contracting Office
- Department of Veterans Affairs;NETWORK 23 CONTRACTING OFFICE;708 S. Third St., Suite 200E;Minneapolis MN 55415
- ZIP Code
- 55415
- Solicitation Number
- VA26317R0859
- Response Due
- 7/7/2017
- Archive Date
- 9/5/2017
- Point of Contact
- Daniel Reinke
- Small Business Set-Aside
- N/A
- Description
- 2 This is a sources sought announcement only. This is not a solicitation announcement. The purpose of this announcement is to gain knowledge of current market conditions relative to NAICS 423450. The Department of Veterans Affairs (DVA), Network Contracting Office 23 (NCO 23), on behalf of Minneapolis VA Health Care System, Minneapolis, MN is seeking to identify any vendor capable of to provide new furniture along with instillation. Background: Prior to issuing a solicitation, and pursuant to the Veterans First Contracting Program, the VA is trying to ascertain if there are any qualified Service Disabled Veteran Owned Businesses (SDVOSB) or Veteran Owned Small Businesses (VOSB) with the capability of providing the below services: (Respondents are not limited to SDVOSB/VOSB concerns; the Government seeks to identify all potentially interested sources): SCOPE: Intra-Aortic Balloon Pump for the Surgery department The Intra-Aortic Balloon Pump to be added to Minneapolis VAHCS shall have the following parts: Item # Part Number/Description Qty 1 MAQUET | CARDIOSAVE HYBRID | EA CARDIOSAVE Hybrid and one (1) year warranty Product includes CARDIOSAVE Blood Pressure Transducer Adapter Cable CARDIOSAVE ECG Trunk Cable - 5 lead û AAMI CARDIOSAVE ESIS Lead Wires 50" û 5 Lead (Op Rm) - AAMI Helium - 3 refillable tanks, 104L Ex 1 2 MAQUET | POWER SUPPLY, REMOVABLE | EA 1 3 MAQUET | CS AC Line Cord | EA 1 4 MAQUET | Cardiosave non-ESIS Lead Wires 50" 5 lead (Gen Purpose) - AAMI EA 1 5 MAQUET | Cardiosave ECG Trunk Cable - 5 lead - AAMI EA 1 6 MAQUET | Cardiosave Blood Pressure Transducer Adapter Cable | EA 1 7 MAQUET | Cardiosave Trainer | EA 1 8 MAQUET | Cardiosave Biomedical Training | EA 1 General Requirements The Intra-Aortic Balloon Pump to be added to MVAHCS shall have the following requirements: Intra-Aortic Balloon Pump (IABP) Battery backup >45min Simulator/trainer available Fiberoptic catheters 150+ bpm tracking rate Transportable Small footprint RS-232 output / interface with ICIP capable MICU/SICU Multiple trigger modes Electrosurgical interference filtering/processing External input for slaving to patient monitors Automatic calibrations of fiberoptic waveforms desirable Automatic and user selectable assist modes Advanced algorithms for patient management Quick initial setup Biomed training Place of Performance Equipment shall be delivered to the Minneapolis VAHCS, One Veterans Drive, Minneapolis, MN 55417 Responses to these sources sought must include the following information. 1. General Information of your company name, address, contact person name, phone number, fax number, e-mail address(s) and DUNS number and company website if available. 2. Socio-economic status of business (i.e. SDVOSB/VOSB) Responses to this market survey shall be e-mailed to the attention of Daniel Reinke, at fax number daniel.reinke@va.gov. No telephone responses will be accepted. Responses must be received no later than 3:30PM CDT July 7, 2017. No solicitation document is available at this time; this notice is to acquire information only. Vendors interested in providing an offer will have to respond to a solicitation announcement that shall be published separately.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/MiVAMC618/MiVAMC618/VA26317R0859/listing.html)
- Document(s)
- Attachment
- File Name: VA263-17-R-0859 VA263-17-R-0859.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3627892&FileName=VA263-17-R-0859-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3627892&FileName=VA263-17-R-0859-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA263-17-R-0859 VA263-17-R-0859.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3627892&FileName=VA263-17-R-0859-000.docx)
- Record
- SN04566018-W 20170702/170630235831-c76592cca76286c89f807318fe988395 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)