65 -- HEMOSPHERE ADVANCED MONITORING PLATFORM - Attachment

Notice Date
6/19/2017
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;VISN/18PHX;777 E. Missouri, Suite 300;Phoenix AZ 85014
 
ZIP Code
85014
 
Solicitation Number
VA25817Q0556
 
Response Due
6/29/2017
 
Archive Date
8/28/2017
 
Point of Contact
LOUIS R WADE
 
E-Mail Address
5-4475<br
 
Small Business Set-Aside
N/A
 
Description
Statement of Work 3 Statement of Work VIGILANCE II MONITOR Phoenix Veterans Administration Health Care Services 650 E. Indian School Road Phoenix, AZ 85012 1.0 Background: 1. This request for the purchase of 3 Vigilance Monitors. This purchase will replace 3 of Vigileo machines which are being phased out by the company this year, therefore they are currently unsupported. Phoenix VA ICU has been using the older version of these machines since 2009 for hemodynamic monitoring of the most complex ICU patients. The ICU staff is confident and competent in the use of the monitoring system and will require minimal training for the new features of the newer version. The purchase of these machines is in line with maintaining quality and safe care to critically compromised Veterans. 2. The EV 1000 Platform is an arterial-based hemodynamic (minimally invasive) monitoring device that includes continuous monitoring of at least: cardiac output, cardiac index, stroke volume, stroke volume index, systemic vascular resistance, systemic vascular index, and SVV to guide patient therapy related to multiple shock states, post-surgical patients, etc. It is the Vigilance Monitor that will provide the continuous cardiac output monitoring in the diagnosis of pulmonary hypertension and sepsis. All these hemodynamic parameters are necessary in the diagnosis and treatment of critical Veteran patients. 2.0 SPECIFICATIONS: Vigilance II Monitor Input/Output Analog Inputs (3) Selectable full-scale: 0 to 1V, 0 to 5V, 0 to 10V; >100 kohms input impedance; Bandwidth = 5 Hz; Resolution: 12 bits ±1 LSB of full scale Analog Output (1) Selectable full-scale range: 0 to 1V, 0 to 10V; Bandwidth = 10 Hz; Resolution = 8 bits; ECG Monitor Input Input voltage range 0 to 10V full scale; Channel Bandwidth = 0.5 to 40 Hz; Resolution = ±1 BPM; Accuracy = ±1 BPM; Range = 30-250 BPM; Digital I/O (2) RS232 programmable serial ports; Maximum data rate = 19.2 kilobaud USB Port One V1.1-compatible type A connector Electrical Voltage 100 to 240 Vac; 50/60 Hz Power consumption 40 watts maximum Fuse Two 1-amp, 250-volt, Time Lag, Low Breaking Capacitance, 5x20 mm 3.0 TASKS: Covers Physical and Liquid Damage to the Equipment (limited) Associated Optical Module Cable Failures Replaced at No Charge Guaranteed Next Day Replacement of Covered Equipment All Parts, Labor and Shipping Costs Covered 24/7/365 Technical & Product Phone Support Year of Manufacturers Warranty Upgraded to Total Protection at No Additional Cost Complete Terms and Conditions Available 4.0 Delivery and Shipping Information: The contractor shall provide the following for shipment and delivery of equipment: All items shall be shipped to the following location: Carl T Hayden VAMC 650 E Indian School Rd Phoenix, AZ 85012 5.0 TRAVEL: The contractor is responsible for all travel-related costs associated with any on-site delivery. 6.0 DELIVERABLES: Deliverable No. Item Quantity Delivery Date 0001 VIG2 - Vigilance II CCO/Oximetry/CEDV Monitor, 110v/ ED-VIG2 Three (3) Within 30 Days of receipt of award. 0002 OM2 OXIMETRY OPTICAL MODULE/ ED-OM2 Three (3) Within 30 Days of receipt of award 0003 70CC2 - Patient CCO Cable/ ED-70CC2 Three (3) Within 30 Days of receipt of award. 0004 VIG2AP - Adapter Plates/ED-VIG2AP Three (3) Within 30 Days of receipt of award. 0005 VIG2 ROLL STAND/ ED-VIG2S Three (3) Within 30 Days of receipt of award. 0006 VIG2TPSRV12 - TOTAL PROTECTION SERVICE VIGILANCE II MONITOR - 1 ADDITIONAL YEAR - PER MONITOR PER YEAR/ED-VIG2TPSRV12 Three (3) Submitted with bid. 0007 SHIPPING TO DESTINATION - Phoenix AZ 85012/FREIGHT Submitted with bid. 7.0 CONFIDENTIALITY AND NONDISCLOSURE: This item does not hold any patient information therefore a security package is not required. In accordance with Appendix A, Handbook 6500.6 Checklist blocks 7, the C&A requirements do not apply to this requirement, and Security Accreditation Package is not required. Due to the non-technical nature of this requirement, in reference to no. 7 there is no information to be protected. If vendor needs access during delivery, assembly or installation, the contractor shall be escorted by a VA employee at all times to ensure there is no exposure to VA sensitive information. 8.0 GOVERNMENT FURNISHED EQUIPMENT: N/A 9.0 HIPPA Compliance: N/A
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PhVAMC/HMC/VA25817Q0556/listing.html)
 
Document(s)
Attachment
 
File Name: VA258-17-Q-0556 VA258-17-Q-0556.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3595627&FileName=VA258-17-Q-0556-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3595627&FileName=VA258-17-Q-0556-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Phoenix Carl T. Hayden VA Medical Center;650 E. Indian School Rd.;Phoenix AZ
Zip Code: 85012
 
Record
SN04549046-W 20170621/170619234601-7036a8dcaccf322b47e364c504f13d21 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.