Y -- MMRP Repair Anacostia Electrical System, JBAB Washington, DC. - Attachment

Notice Date
5/20/2017
 
Notice Type
Attachment
 
NAICS
221122 — Electric Power Distribution
 
Contracting Office
N40080 NAVFAC Washington, PWD Joint Base Anacostia-Bolling 370 Brookley Ave Washington, DC
 
Solicitation Number
N4008017B9001
 
Response Due
5/30/2017
 
Archive Date
6/14/2017
 
Point of Contact
William Boyd III, 202-767-1702
 
Small Business Set-Aside
N/A
 
Description
The project is located at Joint Base Anacostia-Bolling (JBAB), Washington DC. The existing electrical distribution system for Joint Base Anacostia-Bolling is a four-feeder system served from the 15KV Switchgear housed in Building 168. Four PEPCO feeders #15631, 15632, 15633, and 15634 serve the switchgear in Building 168 and are then redistributed throughout the base. Adjacent to Building 168 is the Base electrical redistribution switchgear. Four Navy feeders are connected to this redistribution switchgear from the main switchgear in building 168. Each of the four PEPCO feeders serving the four Navy feeders #704, 705, 706A and 706B are distributed to the Base through separate switches in each of the switchgear section lineups. The existing radial feeder system has certain deficiencies that must be corrected in order to ensure that Base operations continue without service interruptions. The electrical substations located throughout the Base are composed of a feeder selector switch or a line-up of load interrupter switches and a transformer. A significant portion of the feeder selector and air switches are in poor working condition. Many of the internal connections are weather corroded and in some cases, the barrier boards are partially unusable. The majority of the existing feeder selector switches are square singular devices approximately 7 ™ wide by 7 ™ deep. The Replacement switches are to be SF-6 Gas Switches, varying in size. Each Substation will have at least one 3-way SF-6 Gas Switch. The main goals of the project are to provide a loop feeder selective system, demolition of the old electrical equipment, installation of new switches, and replacement of the collapsed duct-bank. Due to the necessity for continued operations on the Base, no substation can sustain an extended power outage. Therefore, generators and associated equipment must be provided to carry the load during any interruption of electrical power related to the project.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/e8cf7698588f39b68e85305d86e0158b)
 
Document(s)
Attachment
 
File Name: N4008017B9001_Source_Sought_MMRP_Repair_Anacostia_Electrical_System.pdf (https://www.neco.navy.mil/synopsis_file/N4008017B9001_Source_Sought_MMRP_Repair_Anacostia_Electrical_System.pdf)
Link: https://www.neco.navy.mil/synopsis_file/N4008017B9001_Source_Sought_MMRP_Repair_Anacostia_Electrical_System.pdf

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: 370 Brookley Ave
Zip Code: Joint Base Anacostia Bolling, Washington, DC
 
Record
SN04516423-W 20170522/170520233052-e8cf7698588f39b68e85305d86e0158b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.