Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 14, 2017 FBO #5621
DOCUMENT

65 -- VA701-17-Q-0166 - Denver Activation CB EQ 005 Various Audiology Equip. - Attachment

Notice Date
4/12/2017
 
Notice Type
Attachment
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs;Program Contracting Activity Central;6150 Oak Tree Blvd, Suite 300;Independence OH 44131
 
ZIP Code
44131
 
Solicitation Number
VA70117Q0116
 
Response Due
4/21/2017
 
Archive Date
7/20/2017
 
Point of Contact
Sandra Mruk
 
E-Mail Address
official email
(sandra.mruk@va.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
INTRODUCTION The Veterans Health Administration (VHA), Program Contracting Activity Central (PCAC) anticipates soliciting quotations and subsequently awarding a Firm-Fixed-Price contract for various audiology equipment for the Eastern Colorado Health Care System. Acquisition of these items is part of the initial outfitting and activation of the new VA Medical Center being constructed in Aurora, CO. DESCRIPTION A contract is needed for the Eastern Colorado Health Care System for various audiology equipment. The contractor shall deliver all items. All items must meet all salient characteristics and the contractor shall furnish all personnel, supplies, and equipment required for delivery. SALIENT CHARACTERISTICS Cabinet with Bench Grinder, Audiology (JSN D6550.1) Quantity: 1 Basis of Design: Starkey Model Starmed Professional Fitting Station or equal Specifications/Salient Characteristics: Dimensions (In as much as one inch) Shall be made out of all steel construction with pull-out work shelf and drawer. Shall be a professional fitting station design to modify any style of hearing aid or earmold Shall be outfitted with an industrial grade diamond bit, quick change chuck, burrs, flexible bits for CIC vent modification, plus adjustable work light and magnification lens. The fitting station buffing wheels shall be designed to prevent damage to the hearing aid. Shall contain tools and modification kits necessary for the professional fitting and service of hearing instruments. Shall have large, heavy duty non marking casters. Approximate Dimensions: 33 W x 26 D x 53 H Power Requirements: 110V, 50/60 Hz, 20 Amps Accessories/Configuration Options:    NA Analyzer, Hearing Aid (JSN D6550.2) Quantity: 1 Basis of Design: Starkey Model AuraCare Optimization System or equal Specifications/Salient Characteristics: Dimensions (In as much as one inch) Shall provide the procedures and technology necessary to perform comprehensive examination of a hearing aid s physical and electrical conditions. Shall clean using ultrasonic vibrations. Shall assess hearing aid s performance. Shall extract obstructions and debris in the microphone, receiver and vent ports. Shall measure battery drain, transducer functionality, and the consistency of volume control taper. Approximate Dimensions: 16 W x 12 D x 11 H Power Requirement: 110V, 50/60 Hz (plugs into bench detailed in 2.5.1 D6550.1) Accessories/Configuration Options: Configuration Vacuum Syringe Assembly Configuration Vacuum Dome Configuration Drain Probe Analyzer, Hearing Aid, AudioScan (JSN M0020) Quantity: 9 Basis of Design: Etymonic Design, Inc. Model Audioscan Verifit 2 or equal Specifications/Salient Characteristics: Dimensions (In as much as one inch) Shall measure real-time binaural simulations (both ears) at the same time with repeatable results Shall have visual confirm streaming between instruments. Shall have a speechmap fitting environment Shall have real calibrated speech and counseling graph Shall have a simultaneous test box directional test Shall have Sensory Loss Simulator with 65 simulation bands for dedicated noise reduction test and frequency-lowering test stimuli Shall have CROS/BiCROS fitting capability Shall have speechmap for telecoil- match acoustic and inductive Shall have user-supplied sound files, FM fitting protocol Shall have the Noah 4 Module and remote operation Shall have Teletest headset for phone streaming verification, dual probes. Shall have a telephone magnetic field simulator and external speaker capability. Shall have a battery drain test Shall have a RECD Transducer and multiple display capability Technical Specification: Weight 15lbs-15.5lbs Display 12 LED Stereo headphone monitor amplifier 250 mW into 16 ohms, L/R Power amplifiers 2 @ 5 watts each Simultaneous stimulus channels 2 Simultaneous measurement channels 2 Connectivity and quantity: WiFi 802.11 B/G/N Ethernet (RJ45) 1 USB 5 HDMI 1 External speakers 2 Test box cable (HDMI style) 1 Probe dock (mini-din) 1 Probe microphone (3.5mm st) 2 WRECD transducer (3.5mm st) 1 Binaural monitor headphone (6.3mm st) 1 Test box ref. mic. (3.5mm st) 2 Binaural coupler microphone (3.5mm st) Battery substitute (3.55mm st) 1 Power supply (4-conductor DIN) 1 Test Box requirements: Isolation @ 1kHz less than 25dB Induction coil test loop 9.2 x 6.7 System analog bandwidth frequency range 10-16000 Hz Display bandwidth (1/3 octave) frequency range 200-12500 Hz Test stimulus levels 40 90 dB in 5 dB steps Test stimulus levels (inductive) 31.5mA/m Test stimulus distortion less than 2% at 90dB SPL and less than 0.5% at 70dB SPL Test stimulus accuracy requirements: +/- 1.5dB SPL @ 200-2000 Hz; +/-2.5dB SPL @ 2000-8000 Hz; +/- 4dB SPL@ 8000-12,500 Hz Analysis frequencies per octave 12 Analysis filter bandwidth (noise) 1/12 octave Measurement accuracy at 1 kHz for tones = +/- 1dB Measurement accuracy re 1 kHz for tones = +/- 1 dB @ 200-5000 Hz and +/- 3dB @ 5000-12500 Hz Measurement range between 30 145dB SPL Harmonic distortion range 200-4000 Hz Approximate Dimensions: Display unit: 14.2 W x 16.4 H x 6.5 D Test Box: 12.1 W x 5.4 H x 12.9 D Power Requirements: 120V, 50-60Hz, 1.35A 0.53A Accessories/Configuration Options: Configuration External REM Option Configuration Simultaneous on-ear direction test Audiometer, Diagnostic, Middle Ear, Impedance (JSN M0025) Quantity: 4 Basis of Design: Grason-Stadler Model TympStar Pro or equal Specifications/Salient Characteristics: Dimensions (In as much as one inch) Shall perform a full battery of middle-ear measurements on patients of all ages. Shall have a 12 color touchscreen display. Shall have zoom function and programmable user test. Shall be stand-alone and PC enabled Shall have multiple probes tone frequencies (226, 678, and 1000 Hz) with diagnostic Tympanometry capabilities. Shall display Acoustic Reflex Decay and Eustachian Tube Function (ETF) and perform screening. Technical Specification: Probe Tones: 226 Hz (85 dB SPL +- 1.5 dB), 678 Hz (72 dB SPL +- 1.5 dB) and 1000 Hz (69 dB SPL +- 1.5 dB) with accuracy of =_1% and Harmonic Distortion of less than 1% Admittance Measurements: Range 226 Hz (-10 to +10 mmho), 678 Hz (-21 to +21 mmho), 1000 Hz (-32 to +32 mmho) Sensitivity Scale Auto Scales to Appropriate Range, Manual selection also possible in Reflex Modes only Accuracy (226 Hz): Typm Mode - +-5% of reading or +- 0.1 mmho, whichever is greater; Reflex Mode - +-5% of reading or +- 0.02 mmho, whichever is greater Pressure Measurements (load volume of 0.2 to 7.0 ml): Range Normal = +200 to -400 daPa Wide = +400 to -600 daPa Accuracy - +- 10% of reading or +- 10 daPa, whichever is greater Sweep Rate 12.5, 50.0, 200, 600 and 600/200 daPa and manual Sweep Accuracy 10% of nominal rate Maximum limits (in 0.5cc cavity) - -800 daPa and +600 daPa Reflex Measurements: Stimuli 250, 500, 1k, 2k, 4k, BBN, LBN, HBN, Click, External Input, Non-acoustic Frequency Accuracy - +-3% Harmonic Distortion (THD) Less than 5% measured acoustically Noise Signals 3 dB bandwidths Low Band 400-1600 Hz High Band 1600 4000 Hz Broad Band 1600-4000 Hz Intensity Range 35-120 dB HL Step Size 5 dB, 1 dB, and 2 dB Calibration Accuracy - +-3 dB Step Accuracy - =_ 0.5 dB On/Off Ratio 70 dB Approximate Dimensions: 16 W x 11 D x 14.5 H Power Requirements: 120V, 50-60 Hz, 60 Watts maximum power consumption Accessories/Configuration Options: Accessory Probe Assembly (including contralateral insert phone) Accessory Eartip sample kit Accessory Calibration Test Cavity Accessory Cleaning Kit Accessory Probe Mount Kit (shoulder, clip, wrist band) Accessory User Quick Guide Accessory Reference Instruction Manual System, Otoacoustic Emissions (JSN M0031.A) Quantity: 1 Basis of Design: Otodynamics Model Otoport Advance Standard Package or equal Specifications/Salient Characteristics: Dimensions (In as much as one inch) Shall have a handheld clinical screening applications instrument that performs diagnostic testing and OAE measurements with data analysis and management features. Shall have large, clear, detailed, color graphic and numeric data displays Shall have a charge status indicators Shall be menu driven operation via keypad with automatic or manual test settings. Shall be able to configure automatic test termination based on signal quality or clinical pass criteria Shall have the following OAE capabilities DPOAE TEOAE TEOAE + DPOAE Shall have onboard data management and analysis Shall have power-on self-test and probe calibration test functions Technical Specification: Interfaces: Probe connector compatible with probes (8pin); Charging data connector to connect to charging station or PC USB Port via data cable Data display resolution 320 x 240 pixels, 166 dpi Data display technology color LCD, 16 bit Audible Indicator - Wide range speaker for audio feedback of status Keypad 19 key alphanumeric with cursor control Internal real time clock and calendar Approximate Dimensions: 7.6 x 2.7 x 1.2 Power Requirements: Internal rechargeable 3.7V, 100mAh lithium-poly battery Accessories/Configuration Options: Accessory Otoport case Accessory Full docking station, connects to printer, PC and charger Accessory Probe pouch Accessory PTEPA/DPOAE probe Accessory Test cavity Accessory Probe cable chip Accessory Foam probe tips Accessory Infection control sleeve Analyzer, Auditory, Evoked Potential (JSN M0035) Quantity: 1 Basis of Design: Otemetrics Model ICS Chartr EP 200 (8-04-11900) or equal Specifications/Salient Characteristics: Dimensions (In as much as one inch) Shall be able to configure wide variety of electrophysiological test and programmable for single protocol or linked protocol operation. Shall allow the operator to select or change the default parameters for a particular test. Shall have a video-based 4 channel and electrode-based 2-channnel vestibular diagnostic system for USB connection with laptop. Shall include binaural video goggles, light bar with ranging, laptop computer and isolation transformer. Shall have AirCal Caloric heats and cools at temperature range from 12 to 50 degrees C that communicate directly with OTMETRICS VNG/ENG solutions. Shall have the capability to select protocol that automatically sets the correct temperature (warm or cold) Shall start the VNG/ENG tracing simultaneously along with the stimulation count down timer. Shall start video recording or center a tracing using the foot switch or trigger button on the delivery head. Shall have two (2) channel auditory evoked potential system which includes insert earphones, bone conduction, TDH headsets and normative data Shall perform the P300 test for Chart EP 200 Shall have an Auditory Steady State Response (ASSR) Technical Specification: Acquisition Options Sweep Time: 5.0 9000 msec Rate: 0.2 to 180/sec A/D Resolution: 16-bit Artifact Rejection: 99% full scale (adjustable) Points per Trace: 600 Channel Options Channels: 2 channel with additional channel available for EMG monitoring Gain: 1k, 1.5k, 2k, 2.5k, 3k, 5k, 7.5k, 10k, 15k, 20k, 25k, 30k, 50k, 75k, 100k, 150k, 200k, 250k, 300k, 500k High Pass Filter (Hz): 0.2, 0.3, 0.5, 1, 1.5, 2, 5, 10, 20, 30, 50, 100, 150, 200, 500, 1000 Low Pass Filter (Hz): 15, 30, 50, 75, 100, 150, 250, 300, 500, 600, 1k, 1.5k, 2k, 3k, 5k, 10k Notch Filter: 50 or 60 Hz set by the manufacturer Stimulus Options Transducer: Headphones, Insert Earphones (automatic 0.8msec delay correction), Bone Oscillator (B71) Stimulus Type: Click & toneburst Masking: White noise Click Duration: 100 usec Toneburst Freq (Hz): 100,125, 200, 250, 300, 400, 500, 600, 700, 750, 800, 900, 1k,1.5k, 2k, 3k, 4k, 6k, 8k Toneburst Ramp/Plateau: User defined (cycles) Toneburst Envelope: Linear, Hanning, Blackman, Gaussian Intensity: 132 dB pe SPL; user definable nHL Polarity: Rarefaction, condensation, alternating Calibration Reference: Calibration table in dB SPL with a user definable normal hearing threshold table in nHL VEMP Monitor Channel: Monitor 1 channel (left or right side) VEMP EMG Level: User defined minimum and maximum acceptable level Chartr EP 200 Dimensions/Weight Chartr EP 200 main unit: 4.9cm x 34.2cm x 28.7cm (2 x 13.6 x 11.3 ) 2.7kg (5 lbs 7oz) Chartr EP 200 Preamp: 3cm x 9.9cm x 16.4cm (1.19 x 3.88 x 6.44 ).27kg (9.5oz) Chartr VEMP Monitor: 2.9cm x 6.2cm x 9.5cm (1.13 x 2.44 x 3.75 ) 2.0kg (4.5oz) Interface: USB to PC Power Supply: 15V DC/2.6A Safety: Chartr EP 200 was designed to meet these standards Standard IEC 60601-1, Class I, Type BF, IPXO: UL2601; CAN/CSA-C22.2 No 601.1-90 Computer Minimum Requirements Processor: Intel i5 RAM: (Windows 7, Windows 8 or Windows 10): 6GB 64-bit (Windows 7 or Windows 8): 6GB Bus Support: USB 2.0 or USB 3.0 OS: Windows 7, Windows 8 or Windows 10 64-bit CD Drive: CD-R/W Display Resolution: Minimum screen resolution of 1600 (horizontal) x 900 (vertical) at 96 dpi or 120 dpi Display Color: 32 bit color ASSR Number of channels: 1 Stimuli: 250, 500, 1000, 2000, 4000, 8000 Hz (up to 6 per ear) presented monaurally or binaurally Threshold search/ 0 - 120 dB HL (insert phones), 0 - 110 dB HL (headphones) Upper lower limit: 0 - 60 dB HL (bone oscillator), 5 dB steps Masking: White noise up to 100 dB HL AM/FM Modulation: 20 to 105 Hz(1 Hz per step); AM depth - 0 to 100%, (5% per step); FM depth - 0 to 25% (5% per step) Gain: 1k, 2k, 3k, 5k, 10k, 20k, 30k, 50k, 100k, 200k, 300k, 500k High Pass/Low Pass Filter: Exclusive Chartr narrow filters for RapidASSRTM EEG: Online display during data collection or when collection is paused Search Options: Quick Search or Straight Descent Electrode Montage: Cz to Nape or Cz to Linked Mastoids Test Protocols: Test protocols included for sleeping and awake patients. Protocols can be created and customized. Approximate Dimensions: 6.3 L x 4.1 W x 2.2 D Power Requirements: AC/DC Adapter Accessories/Configuration Options: Configuration P300 test Configuration Vestibular Evoked Myogenic Potential (VEMP)   Configuration Auditory Steady State Response (ASSR) Configuration Test Fixture - checks the working condition of the auditory stimulus and data collections portions of the Chartr EP 200 hardware. Meter, Sound Level (JSN T8040) Quantity: 1 Basis of Design: 3M, Model or equal Specifications/Salient Characteristics: Dimensions (In as much as one inch) Shall perform environmental and occupational noise measurements that accurately measures, documents, and displays noise exposures to support hearing conservation. Shall be able to measure multiple sound levels and conduct Octave band analysis. Shall include removable SD memory card Shall be a Class/Type 1 Shall have a removable preamp with English as its display language. Shall perform statistics for community noise Shall be CE Mark, WEEE, RoHS Certified Technical Specification: Parameters: SPL, LMax, LMin, LPk(peak), LEQ/LAVG, SEL, LN (selectable L1 to L99), TWA, Taktm, Taktmx, Dose, PDose, Exposure (Pa2H/Pa2S), LDN, CNEL, PTWA, L C-A Ranges: 120 dB+ (A-weighted) total dynamic measurement range over 8 individual ranges of 90 dB (A-weighted) each (with filters - 80 dB ranges); overall measurement range 0 dB to 140 dB Peak Range: Up to 143 dB using standard BK4936 microphone; higher with optional microphones and preamps Frequency Weighting: A, C, Z and F (Flat) Response Time: Fast, Slow, IEC Impulse Exchange Rates: 3, 4, 5, and 6 dB Criterion Level: 40 to 100 dB Upper Limit Time Logging: 10 to 140 dB selectable Run Modes: Level triggered run/pause, clock/date triggered power on and run for programmed duration, external logic input run/pause, and keypad initiated run/pause for programmed duration Measurement References: SPL: 114 dB Frequency: 1 kHz Direction: 0 degrees using free-field response microphone Approximate Dimensions: 3.1 W x 11.1 H x 1.6 D Power Requirements: Batteries: 4 disposable AA Alkaline cells Accessories/Configuration Options: Configuration Detection Management Software (DMS) designed for dosimetry, sound level measurement and environmental monitoring. This software configures, analyzes, and reports. Vacuum, Hearing Aid (JSN Z1102) Quantity: 6 Basis of Design: Jodi-Vac Model Jodi-XL with Air Pressure or equal Specifications/Salient Characteristics: Dimensions (In as much as one inch) Shall be a small vacuum system with air pressure that removes debris and moisture from all styles of hearing instruments. Shall have three needles, arranging in size to efficiently clean large earmolds, ITE, ITC, CIC, RIC and thin tubes and two reamers. Shall have three air pressure vent reamers, a power supply desktop transformer, and interchangeable AC cords. Technical Specification: Pump: Vacuum is 22.5 inches of Mercury, Pressure is 38 PSI, Desiccator is 22.5 inches of Mercury Pumps are serviceable and motors are rated at 2,000 hours Electrical: Internals operate on 12VDC and Power Supply is universal 100-260Vac, 50/60Hz Ac cords are interchangeable for international use Desiccator: Heating is achieved with no feedback controls for reliability and is fireproof Vacuum pump automatically shuts off for silent operation during drying process The desiccator @ 105-107 degrees F. with a dry (blue) desiccant will remove two drops of water in approximately 20 minutes. Desiccator Chamber measures 4.5 Diameter X 2.5 tall Desiccant can be rejuvenated by microwaving. Blue is Serviceable, Pink is Moisture laden Desiccant Indicator Light is on when heater is on and under vacuum. Air Pressure: ISO LuerLoc assembly is permanently attached to blue tubing 3 reinforced flexible air pressure needles used as a vent reamer, excluding pressure vents. Blue coiled tube extends to a full length of 35. Air pressure also serves to dry and blow debris from battery compartments, volume controls, push buttons and switches Vacuum: ISO LuerLoc Clear filter assembly is replaceable Wax/Debris collects in filter assembly and a busy office should get 6 months of use from one filter Assembly providing liquids are not introduced. See accessories page- liquid filter Vacuum filters are not serviceable, replace when full. Ball located behind filter is a flow indicator, unclogged- ball rises to connector Three needles are provided, Covering the highly efficient cleaning of CIC s, ITC s, ITE s, RIC s, Open Ear Thin. Tubes and Ear Molds. Needles are cleaned with a needle reamer. Blue coiled tube extends to a full length of 35 Approximate Dimensions: 6 W x 9 L x3 H, with desiccant lid and tubing 6 H Power Requirements: AC voltage from 100-240vac, operating at 50/60Hz Accessories/Configuration Options: Accessory Coiled Tubing with Liquid Trap/Filter Accessory Straight Tubing w/Liquid Trap/Filter Accessory Straight Tubing w/Standard Filter Accessory Auto Power Adaptor Operation and Maintenance Manuals Binders - Quantity (2) each for items identified above. Digital Copies - Quantity (1) each for items identified above. Deliver compilation of all manufacturer recommended maintenance schedule and operation materials packaged in binder(s) to On Site Point of Contact upon completion of delivery. DELIVERY Delivery time frame: No earlier than 17 April 2017, no later than 1 Jun3 2017. Acquisition of the above items is part of the initial outfitting and activation of the new VA medical center being constructed in Aurora, CO. Since construction is still occurring, delivery dates are approximate and will be coordinated with the successful contractor after award. The Contractor shall contact the On Site Point of Contact to schedule a pre-delivery meeting to be conducted approximately 60 days prior to the initial award delivery date for verification of delivery dates. The Contractor may be required to adjust the delivery date from the date specified in the contract award document. A government-requested delivery delay up to 90 days after the delivery date specified in the contract award shall be at no additional cost to the government. Delivery Location: Contractor shall deliver all equipment to the Eastern Colorado Health Care System, 1700 N. Wheeling Street, Aurora, CO 80045. Delivery Markings: Contractor shall deliver items in manufacturer's original sealed containers with manufacturer s name marked thereon. Deliveries shall be marked with the PO and contract number. INSPECTION AND ACCEPTANCE The Contractor shall conduct a joint inspection with the On Site Point of Contact upon completion of delivery. In the event deficiencies are identified, the Contractor shall provide date when the identified deficiencies will be addressed if not addressed on the date of delivery. The Contractor shall conduct a joint inspection with the On Site Point of Contact after addressing all deficiencies. All deficiencies identified during joint inspections shall be fixed by the Contractor prior to government acceptance of the item. Disputes shall be resolved by the Contracting Officer. WARRANTY The contractor shall provide all manufacturer(s) warranties on all parts and labor at time of delivery. The warranties shall include all travel and shipping costs associated with any warranty repair. OPERATOR TRAINING The Contractor shall provide end user operator and preventive maintenance training as follows: Section 2.5.3 M0020 provide 8 hours of training not to exceed one day for fifteen Providers and Technicians Section 2.5.4 M0025 provide 8 hours of training not to exceed one day for fifteen Providers and Technicians Section 2.5.6 M0031.A provide 8 hours of training not to exceed one day for fifteen Providers and Technicians Section 2.5.7 M0035 provide 8 hours of training not to exceed one day for fifteen Providers and Technicians Section 2.5.8 T8040 provide 8 hours of training not to exceed one day for three Providers and Technicians ADMINISTRATIVE The solicitation will be issued as a Request for Quote (RFQ) conducted in accordance with Federal Acquisition Regulation (FAR) Parts 12 and 13. The solicitation will be advertised as a total Service-Disabled Veteran-Owned Small Business set-aside. The applicable NAICS code is 334510 with a size standard of 1,250 Employees. The solicitation will be issued on or about April 14, 2017 for approximately seven (7) calendar days. Offerors will be required to submit their quotes electronically via email. This notice is not a request for competitive offers. Questions of a technical nature will not be answered as part of this notice; however, all general questions may be submitted in writing to the issuing office via email at Sandra.mruk@va.gov and Michelle.Rhodes@va.gov. Telephone calls will not be accepted. The VA reserves the right to use only Federal Business Opportunities (FBO), via the internet, to provide notification of any amendments to this notice and the subsequent issuance of the solicitation. It is the contractor s responsibility to view FBO daily for any amendments to this notice and the subsequent issuance of the solicitation.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/ISC/OISC/VA70117Q0116/listing.html)
 
Document(s)
Attachment
 
File Name: VA701-17-Q-0116 VA701-17-Q-0116_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3410040&FileName=VA701-17-Q-0116-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3410040&FileName=VA701-17-Q-0116-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: VA Eastern Colorado Health Care System;1700 N. Wheeling St.;Aurora;CO
Zip Code: 80045
 
Record
SN04470482-W 20170414/170412235208-711d6a9e489abdfdbbec447b227657b6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.