SOURCES SOUGHT
65 -- Ventilator, Maquet Servo U plus accessories
- Notice Date
- 3/29/2017
- Notice Type
- Sources Sought
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of the Air Force, Air Education and Training Command, 502d Contracting Squadron, 1655 Selfridge Avenue, JBSA Lackland, Texas, 78236-5253, United States
- ZIP Code
- 78236-5253
- Solicitation Number
- FM301670670034
- Archive Date
- 4/25/2017
- Point of Contact
- Todd M. Martinez, Phone: 210-808-0221, Gary Beck, Phone: 2108086146
- E-Mail Address
-
todd.m.martinez2.civ@mail.mil, gary.d.beck4.civ@mail.mil
(todd.m.martinez2.civ@mail.mil, gary.d.beck4.civ@mail.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- This is a Sources Sought notice only and not a solicitation. The requirement is not yet funded. If a request for quote is issued, it will likely be set-aside 100% for small business under NAICS 339112. Interested parties are requested to submit their size and socio-economic status. If inclined, please include estimated pricing for budgetary use only. FOB destination to Ft Sam Houston, TX. Also include expected delivery time and any available GSA or other GWAC contract information. A solicitation may be issued as a Brand Name Only requirement for the Maquet Servo U and accessories. No substitutes will be considered. A Brand Name Justification will be provided if appropriate. MINIMUM REQUIREMENTS/SPECIFICATIONS/SALIENT CHARACTERISTICS One (1) Maquet Critical Care Ventilator, Servo U, Base Unit (cat# 6694800) to include the following accessories/options: One (1) Maquet Handle, New Servo U (cat# 6880248), One (1) Maquet Upgrade via e-delivery, Servo U (cat# 6880519), One (1) Maquet SW Basic Options Servo U (cat# 6884004), One (1) Maquet Country Kit, US, DISS, N AM*CSA*Servo U (cat# 6883408), One (1) Maquet USB Memory Stick Servo Ventilators (cat# 6880101), One (1) Maquet Mobile Cart Servo U/Servo N Flat pack (cat# 6693695), One (1) Maquet Servo U Support Arm 178 (cat# 6693715), One (1) Maquet Servo U/Servo N Humidifier Holder (cat# 6693735), One (1) Maquet O2 Sensor, Factory Installed (cat# 6670680), One (1) Maquet Hose Air yellow 4.5M M/F - Diss (cat# 6419787), One (1) Maquet Hose O2 green 4.5M M/F - Diss (cat# 6419944), One (1) Maquet Diss, Air Filter (cat# 6419951), One (1) Maquet SW Automode, Servo U (cat# 6693655), One (1) Maquet SW NIV Servo U (cat# 6880513), One (1) Maquet SW Neonatal Option, Servo U (cat# 6880514), and One (1) Maquet SW Nasal CPAP, Servo U (cat# 6880515). Ventilator Essential Characteristics: Unit shall have a TFT -LCD touch screen control panel with 15 in XGA, 1024 x 768 pixels with a 24-bit color palette and the following views Basic View, Advanced View, Loops View, Distance View, Family View and each screen layout views offers a specific combination of displayed loops, waveforms and presented values. Unit shall support monitoring and treatment of neonatal, pediatric and adult patients; Unit must provide monitoring of the patient's breathing drive, improve synchrony between the ventilator system and patient when the electrical signal from the brain to the diaphragm is active and be able use on all patients with no contraindication for insertion/exchange. Unit must have these General Ventilation Specifications: Patient range: Standard configuration: 7 lbs. to 551 lbs. 2 oz. (3 to 250 kg); Neonatal option: 11 oz. to 17 lbs. 10 oz. (0.3 to 8 kg); Bias flow: Adult: 2 l/min; Pediatric and neonatal: 0.5 l/min; internal compressible factor: Max. 0.2 ml/cmH2O; Gas delivery system: Microprocessor controlled valves; Maximum airway pressure: 125 cmH2O; Method of triggering: Flow, pressure and Edi (with Edi module and Edi catheter); Inspiratory flow range: Adult: 0 to 200 l/min; Pediatric and neonatal: 0 to 33 l/min; Pressure drop: Max. 6 cmH2O at a flow of 60 l/s (insp. channel); Max. 3 cmH2O at a flow of 60 l/s (exp. channel); PEEP regulation: Microprocessor controlled valve; Rise time, expiratory flow measurement: <12 ms. for 10% to 90% response at flow of 3 to 192 l/min, Expiratory flow range: 0 to 192 l/min. Unit must have the following Gas Supply Specifications: Inlet gas pressure air/O2: 200 to 600 kPa / 2.0 to 6.0 bar / 29 to 87 PSI; Connection standards available: AGA, DISS, NIST, or French standard; Unavailable gas/loss of gas pressure: The flow from an unavailable gas (air or O2) is automatically compensated for so that the patient gets the preset volume and pressure; Patient system gas connectors: Male 22 mm / female 15 mm in accordance with ISO 5356-1; Gas exhaust port: Male 30 mm cone. Must have humidification holder bracket. VGA port to connect to external monitor for classroom instruction. Unit must have the following Invasive Ventilation Mode Specifications: (INVASIVE) Controlled ventilation: Pressure Control, Volume Control, Pressure Regulated Volume Control; Supported ventilation: PS/CPAP (Pressure Support / Continuous Positive Airway Pressure), Volume Support; Automode (option): Control mode: VC <-> Support mode: VS, Control mode: PC <-> Support mode: PS, Control mode: PRVC <-> Support mode: VS; Combined ventilation: SIMV (VC) + PS (Synchronized Intermittent Mandatory Ventilation), SIMV (PC) + PS, SIMV (PRVC) + PS, Bi-Vent/APRV (Airway Pressure Release Ventilation) and Neurally Adjusted Ventilatory Assist via endotracheal tube or tracheostomy. (NON-INVASIVE) Controlled ventilation: NIV PC (option); Supported ventilation: NIV PS (option), Nasal CPAP (option);NIV: Neurally Adjusted Ventilatory Assist via non-invasive patient interfaces (option). Unit must also have these Non-invasive Ventilation Specifications: Maximum leakage compensation level: Neonatal/pediatric: 25 l/min (20 l/min Nasal CPAP); Adult: 65 l/min; Disconnection flow (configurable): Low: 7.5 l/min, High: Adult - 40 l/min, Neonatal/pediatric - 15 l/m. A unit Log Function for events/diagnostics, and ability to record data (30 seconds), saving screenshots (up to 40), and exporting files via USB memory stick, are all requirements for this unit. Dimensions: Width of 26 inches, a Depth of 22 inches and a Height of 54 inches (dimensions with cart) Shall have electrical specs equal to 100-240 VAC 50/60hz. End.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AETC/LackAFBCS/FM301670670034/listing.html)
- Place of Performance
- Address: METC Logistics, 2220 Wheelright Street, JBSA Ft Sam Houston, Texas, 78234, United States
- Zip Code: 78234
- Zip Code: 78234
- Record
- SN04451251-W 20170331/170329234704-a4aa4358ce6e788734305bc2058c605f (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |