DOCUMENT
65 -- (C)(660) Heart/Lung Machine - Attachment
- Notice Date
- 2/6/2017
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office;NCO 19;4100 E. Mississippi Avenue, Suite 900;Glendale CO 80246
- ZIP Code
- 80246
- Solicitation Number
- VA25917N0221
- Response Due
- 2/9/2017
- Archive Date
- 4/10/2017
- Point of Contact
- Kurt Tanny
- Small Business Set-Aside
- N/A
- Description
- Sources Sought: VA259-17-N-0221 Heart Lung Perfusion Machines - Salt Lake City VA Medical Center This is Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal. An award will not be made on offers received in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing information provided. Responses shall be submitted by 12:00pm EST on Thursday, February 9th, 2017. This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential vendors, including Small Business, Veteran-Owned Small Business (VOSB), and Service-Disabled Veteran-Own Small Business (SDVOSB) vendors relative to the North American Industry Classification System (NAICS) Code 339112. Department of Veterans Affairs, Network Contracting Office 19 (NCO19) is seeking responses to this request for information from interested, capable firms that can meet the requirements set forth below; The overall purpose is to provide Heart-Lung Perfusion Machines to the George E. Wahlen Department of Veterans Affairs Medical Center located at 500 Foothill Drive, Salt Lake City, UT 84148. SALIENT CHARACTERISTICS (BRAND NAME OR EQUAL TO): HEART LUNG PERFUSION SYSTEM Quantity: 2 (each) Basis of Design: Sorin (LivaNova), S5 Heart Lung Perfusion System Specifications/Salient Characteristics Catalog No. Description Quantity Per System S5 Consoles 48-40-00 4-Pump console (includes: Timer, power supply, emergency power supply, electronic and power supply pack and mast system) 1 45-09-10 Cable holding and organizing system 1 45-09-11 Cable holding and organizing system 1 43-42-61 Cap for fast clamp (6 pcs.) 1 45-95-11USA Operators Manual 1 S5 Pump Modules 10-80-00 Single roller pump 1 10-85-00 Double Roller Pump 1 10-84-64 Double Pump Tray 1 Variolock Tubing Gate and Accessories 10-81-30 Tubing Gate 1 S5 Control Desk 28-95-00 4-slot system Panel 1 28-95-10 Display Module 4 S5 Control Devices and Monitors 22-20-20 Pressure sensor module (2 channel) 1 20-30-20 Temperature sensor module (4 channels) for YSI probes 1 23-40-00 Level Sensor (incl. 23-27-40, 23-27-41) 1 75-521-548 Holder (required for Level Sensor II 23-27-40) 1 23-27-60 Mounting pads, Level sensor II 1 23-45-00 3/8" Bubble sensor module w/420 mm holder, incl. (23-07-50, 23-26-96, 23-45- 20 and 96-06-10) 1 10-07-48 Tubing insert, metal, 3/8 X 3/32, BLUE 1 S5 Accessories - Masts and Crosstrays 48-41-19 Crosstray 4 position W/Power Outlet 1 S5 Miscellaneous 35-05-70 Led Lamp 24V 1 SCP Centrifugal Pump 60-00-60 CP5 System 1 45-90-75USA Operator Manual for the CP5 60-00-60 1 60-05-65 ERC Clamp (620 mm) 1 45-91-71USA Operator Manual for the ERC Clamp 1 0264-2049 Abbott Transpac IV Pressure Transducer Cable 2 CONNECT DATA MANAGEMENT SYSTEM: Catalog No. Description Quantity Connect DMS 24-90-30 Connect Recorder for S5 & C5 Customers 2 24-90-45 Connect Manager with Dongle 1 45-90-14USA User Manual Sorin Connect 2 45-90-74USA User Manual Datapad II 2 Connect DMS Connection Fees 1 80276025 Connection to Terumo CDI 500 1 45-12-61 CONN Cable, CDI 100/500 2 080332000 Connection to CareScape B650/B850 1 45-12-66 CONN Cable, S5, Datex 2 45-12-47 DMS Cable, 5M Extension 2 080276017 Connection to Quest Medical Cardipolegia Pump 1 45-12-08 CONN Cable, S5, Special Cable to S5 Converter Compatibility: Compatible with CareScape B850 Compatible with existing supporting supplies and disposables. Intended Use(s): In the operating room, the heart-lung machine is used primarily to provide blood flow and respiration for the patient while the heart is stopped. Surgeons are able to perform coronary artery bypass grafting (CABG), open-heart surgery for valve repair or repair of cardiac anomalies, and aortic aneurysm repairs, along with treatment of other cardiac-related diseases. The heart-lung machine provides the benefit of a motionless heart in an almost bloodless surgical field. Cardioplegia solution is delivered to the heart, resulting in cardiac arrest (heart stoppage) Responding companies shall include any relevant information (specifications, cut sheets, brochures, capability statement, etc.) confirming their ability to supply product with the salient characteristics outlined in this request. In addition to providing all documents necessary to validate the above requirements can be met (or exceeded), interested vendors shall include with their response: Complete Company Name and Address: DUNS Number: Applicable NAICS Code and Business Size: Company Point of Contact (PCO) Name: Email Address: Phone Number: Teaming Agreements or Joint Venture Partners (if Large Business): Delivery and installation lead-time: Place of Manufacture: State if items are available through an existing Government-wide Acquisition Contract (GWAC), GSA Multiple Award Schedule (MAS) contract, or VA-wide Acquisition Contract. Responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract or agreement. This notice shall not be construed as a commitment by the Government to issue a solicitation, or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/VA25917N0221/listing.html)
- Document(s)
- Attachment
- File Name: VA259-17-N-0221 VA259-17-N-0221.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3257463&FileName=VA259-17-N-0221-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3257463&FileName=VA259-17-N-0221-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA259-17-N-0221 VA259-17-N-0221.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3257463&FileName=VA259-17-N-0221-000.docx)
- Record
- SN04391734-W 20170208/170206234559-757f72d2b96d1f973ec852ca410a88f1 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |