Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 01, 2017 FBO #5549
DOCUMENT

65 -- DUAL STELLANT W/CERTEGRA - Attachment

Notice Date
1/30/2017
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Great Lakes Acquisition Center (GLAC);Department of Veteran Affairs;115 S 84th Street, Suite 101; WI 53214-1476
 
ZIP Code
53214-1476
 
Solicitation Number
VA69D17N0531
 
Response Due
2/2/2017
 
Archive Date
5/3/2017
 
Point of Contact
Michael J Rosenthal
 
Small Business Set-Aside
N/A
 
Description
This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential vendors, including Small Business, Veteran-Owned Small Business (VOSB), and Service-Disabled Veteran-Own Small Business (SDVOSB) vendors relative to the North American Industry Classification System (NAICS) Code 339112. The Milwaukee VA Medical Center has a need for a brand name only One (1) Medrad Stellant Dual Injector and Certegra Workstation. Medical Imaging is in need of a power injector system to inject contrast medial into the bloodstream of patients who are scheduled for CT exams in the Emergency Room CT scanner. General Requirements 60726807 - SCT 322 DUAL STELLANT W/CERTEGRA WKS & OCS 1 each 60339153 - SW APP, P3T BUNDLE, CARD, ABD, PA, 1.X 1 each 60720221 - CT - STELLANT OPS MANUAL 1 each 60721333 - MAN, SERVICE, STELLANT, MC 1 each 59943360 - INSTALLATION - STELLANT WITH OCS 1 each Salient Features Dual Injector Head 6.1 (H) x 12.1 (W) x 14.5 (D) 17.9 lbs Display Control Unit with stand 13.5 (H) x 15.8 (W) x 10.2 (D) 17.6 lbs Dual Injector Head c. Base Unit 11.5 (H) x 11.0 (W) x 8.8 (D) 13.6 lbs Flow rate of 0.1 to 10 mL/sec on 0.1 mL increments Volume 1mL to syringe capacity in 1 mL increments Programmable pressure limit 200 mL syringe: 325 psi, 2241 kPa Scan delay: 0-300 seconds in 1 second increments Pause: 1-900 seconds in 1 second increments Maximum hold time: 20 minutes 200 mL sterile disposable syringe 6 maximum number of phases 250 maximum number of protocols Syringe heater range: 95 ± 9 °F Electrical Requirements: 100-240 VAC, 50/60 Hz, 300 V-AMPs Mounting: overhead counterpoise system compatible Designed for complex CTA and Cardiac CT protocols Creates a tight contrast bolus for better visualization Enables precisely timed contrast delivery Reduces streaking or beam hardening artifacts in Cardiac CT Snap-on/twist-off syringe design Automatic filling and priming with touch of a button Integrated saline test inject Uses weight based dosing for contrast dosing Certegra P3T Abdominal CT Supports imaging of liver, pancreas, and kidneys Certegra P3T Pulmonary Angiography CT Better contrast enhancement of pulmonary arteries Certegra P3T Cardiac CT Enables more consistent images across varied patients, studies, and technologists Eliminates need to estimate injection protocols for complicated studies Simplifies the development of protocols for cardiac imaging DualFlow technology This is not a Request for Proposal or an announcement of a solicitation and no solicitation package exists at this time. Your responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submittals will not be returned to the sender. The applicable North American Industry Classification System (NAICS) Code for this requirement is 339112 and the small business size standard is 1000 employees. Responses due are to be submitted by e-mail to Michael J Rosenthal at Michael.rosenthal@va.gov. The information requested must be received no later than 2:00 pm Central Standard Time on Thursday, February 02, 2017.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAGLHS/VAGLHCS/VA69D17N0531/listing.html)
 
Document(s)
Attachment
 
File Name: VA69D-17-N-0531 VA69D-17-N-0531.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3241366&FileName=VA69D-17-N-0531-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3241366&FileName=VA69D-17-N-0531-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Clement J Zablocki;VA Medical Center;5000 W National Ave;Milwaukee WI
Zip Code: 53295
 
Record
SN04384809-W 20170201/170130234120-1b7502b73980f2418b9dcd5368b3bb33 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.