Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF NOVEMBER 18, 2016 FBO #5474
DOCUMENT

66 -- Homogenizer system - Attachment

Notice Date
11/16/2016
 
Notice Type
Attachment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
US Department of Veterans Affairs;Veterans Health Administration;Service Area Office (SAO) East;323 North Shore Drive, Suite 500;Pittsburgh PA 15212-5319
 
ZIP Code
15212-5319
 
Solicitation Number
VA24017Q0028
 
Response Due
11/21/2016
 
Archive Date
2/19/2017
 
Point of Contact
Contracting Officer: Michael Haydo
 
Small Business Set-Aside
Veteran-Owned Small Business
 
Description
This is a PRE-SOLICITATION NOTICE of a proposed requirement to award one (1) Homogenizer System. This action also requires shipping and all necessary items to immediately start processing. # Description Est. Qty. Unit 1 Homogenizer Thermo Fisher Bead Mill 4 or equal 1 EA 2 Heracell VIOS 160i CO2 incubators or equal. 1 EA 3 Gas Guard 1 EA 4 Refrigerated table top centrifuge capable of processing cell culture, tissue samples and blood separation. Variable speed/force also required for processing multiple sample types. Need Tissue culture rotor adaptor package (item 5). 1 EA 5 Tissue adaptor set for use with item #4 Salient Characteristics Item #1 Homogenizer Thermo Fisher Bead Mill 4 or equal: Mixer/homogenizer capable of processing at variable speed/force for the extraction of multiple tissue and sample types in a variety of vessel sizes. Variable speed/force settings 30-150xg Sample volume 24 µl to 6ml Programmable settings allow for reproducible extraction of proteins and nucleic acids Interchangeable sample vessel sizes; 4 x 0.5ml, 4 x 1.5ml, 4 x 2.0ml and 1 x 7ml Dimensions 8.5 Wx11.5 Dx10 H or less Item #2 Heracell VIOS 160i CO2 incubators or equal: CO2 incubators for the culture of several mammalian cell types. Many of which are primary cells that have more stringent culturing conditions requiring the most stable temperature and CO2 levels. In addition some of these cells must be cultured without antibiotics requiring incubators that provide maximum contamination prevention. Solid copper chamber which eliminates microbial contaminants Active airflow to evenly distribute humidified air with equal to or less than 10 minute recovery if flow conditions ISO 5 HEPA filtration capable of cleaning room air in 5 minutes or less Protected humidity reservoir; limits particle contamination of reservoir, allows for condensation free chamber with 5x faster recovery In Situ sensors and probes for maximal stability of temperature and CO2 levels Steri-Run defection cycle; 180 C cycle assures uniform 6-log sterilization of all chamber surfaces and is completed in under 12 hrs. Stackable units with dimensions 22.7 Dx 35.6 Hx25.1 W (to fit into available space bldg. 13/217) Item #3 Gas guard Tank switcher for above incubators; required accessory to allow for multiple CO2 tanks to be attached and automatically change from empty tank to full tank. Item #4 Refrigerated table top centrifuge capable of processing cell culture, tissue samples and blood separation. Variable speed/force also required for processing multiple sample types. Need Tissue culture rotor adaptor package (item 5). Operating temperature range of -10 to +40 C with pre-cool function and double temperature management for air temperature and sample temperature Maximum RCF of 25,999xG Programmable memory; minimum 90 programs including in run time/speed adjustments Patented lid locking technology with snap on biocontainment seal system SMARTSpin technology for advanced rotor management to maximize acceleration, braking and load imbalances Auto-Lock rotor system for secure locking of rotor following installation or exchange Dimensions 23.8 Lx24.5 Wx14.2 (34.3 open)H to fit on bench in bldg13/217. Item #5 Tissue adaptor set for use with item #4 5/7ml tube adaptor necessary for tubes used to blood collection Shipping FOB Destination shall be included in the overall price. The Veteran s Health Administration Service Area Office - East estimates a posting date of solicitation VA240-16-Q-0028 on November 21, 2016 and distributed solely through the Federal Business Opportunities (FBO) Website (www.fedbizopps.gov). This notice does not constitute a Request for Quote (RFQ) and should not be construed to as a commitment of any kind by the Government to issue a formal solicitation or ultimately award a contract. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Any costs incurred by interested parties will NOT be reimbursed. It is the responsibility of any interested party to monitor this site for additional information pertaining to this notice. The agency is contemplating single award of a firm fixed price (FFP) contract to the contractor whose submission represents best value to the Government. The North American Industry Classification System code is 334516 Analytical Laboratory Instrument Manufacturing. Interested parties shall be registered in the System for Award Management at (www.sam.gov). Contracting Office Address: 323 North Shore Dr. Pittsburgh PA, 15212 United States Primary Point of Contact: Michael Haydo Contracting Officer Email: michael.haydo@va.gov Phone: 412-822-3158
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/87ad2cba0cdaab72be68ee7b0f783f04)
 
Document(s)
Attachment
 
File Name: VA240-17-Q-0028 VA240-17-Q-0028_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3110632&FileName=VA240-17-Q-0028-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3110632&FileName=VA240-17-Q-0028-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;Seattle, WA
Zip Code: 98108
 
Record
SN04329733-W 20161118/161116234738-87ad2cba0cdaab72be68ee7b0f783f04 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.