H -- Electrical Distribution Testing - Attachment

Notice Date
11/3/2016
 
Notice Type
Attachment
 
NAICS
221122 — Electric Power Distribution
 
Contracting Office
Department of Veterans Affairs;VA Black Hills HCS;Fort Meade Campus;113 Comanche Rd.;Fort Meade SD 57741
 
ZIP Code
57741
 
Solicitation Number
VA26317Q0063
 
Response Due
11/10/2016
 
Archive Date
11/25/2016
 
Point of Contact
David A Raad
 
E-Mail Address
7.2511
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Page 1 of 1 DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTERS SAINT CLOUD HCS STATEMENT OF WORK Maintenance, Inspection, and Testing of the Electrical Power Distribution System Revise: May 25 2016 1. Introduction: This Statement of Work (SOW) describes the requirements for the maintenance, inspection, testing, and/or calibration of the Electrical Power Distribution System and all of its components. These work items are referenced as Maintenance and Testing in this document, hereafter. This SOW describes the requirements for the Qualified Electrical Contract Professionals known as Contractors in this document, hereafter. Contractors who are contracted by VHA Medical Center to perform maintenance and testing of the Electrical Power Distribution System, and all of its components shall meet all requirements stated in Section 2 of this SOW. This SOW describes the requirements to establish maintenance and testing reports. 3. Summary of Work: Work is to be performed at the St. Cloud VA Health Care System, located at 4801 Veterans Drive, St Cloud, MN 56303. Work is to be coordinated with Arnie Tenney, Lead Electrician/COR at (320)255-6451. Much of the work will need to be completed after the normal tour of 8am to 430pm. Service is to be completed by October 4, 2016. Items to be cleaned, inspected, and tested are listed on the accompanying Word document. Equipment to be serviced is located throughout the campus. Site plan has been included. Work items, definitions, and references shall comply with the latest edition of the NETA Maintenance Testing Specifications. Work performed will follow the latest ANSI/NETA inspection and testing procedures. Contractor must also follow VHA Directive 1028. Infra-red scanning does not need to be included in this requirement. Preferred method for testing circuit breakers 250 Amps and larger is secondary injection through electronic test port. Oil sampling and testing for 27 medium voltage liquid filled transformers shall also be included as part of this service. Additionally, part of our substation maintenance requires battery replacement. Information for those is listed on the attached Word Document, Items for Electrical Maintenance and Testing.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VABHHCS568/VABHHCS568/VA26317Q0063/listing.html)
 
Document(s)
Attachment
 
File Name: VA263-17-Q-0063 VA263-17-Q-0063_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3089765&FileName=VA263-17-Q-0063-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3089765&FileName=VA263-17-Q-0063-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: VAMC St Cloud;4801 Veterans Drive;St Cloud, MN
Zip Code: 56303
 
Record
SN04320306-W 20161105/161103234914-fafad058a16b0c8021062ad002563805 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.